REFLECTION 71333324Recalls & reported problems
Smith & Nephew, Inc. · REFLECTION XLPE 28MM INNER DIAMETER 20 DEGREE 50-52MM OUTER DIAMETER SIZE E · Class 2 · Implant
- Adverse event reports
- 15
- Deaths reported
- 0
- Injuries reported
- 14
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 03596010455611), received between Feb 17, 2018 and Dec 29, 2021 — classified as 14 injuries, 1 malfunction.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (6 reports).
1 other recall cover devices cleared under the same FDA submission (K002747, K211176); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device Dislodged or Dislocated6
- Insufficient Device Problem Information4
- Defective Device2
- Connection Problem1
- Difficult to Insert1
- Incomplete or Inadequate Connection1
- Unintended Movement1
- Unstable1
Patient problems
- Injury11
- Joint Dislocation10
- No Known Impact Or Consequence To Patient2
- Failure of Implant1
- No Information1
- Osteopenia/ Osteoporosis1
- Unspecified Infection1
Recent adverse event reports
The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.
InjuryDec 29, 2021Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT, AFTER A THR, PERFORMED SIXTEEN YEAR AGO (2005), THE PATIENT EXPERIENCED 2 RECENT DISLOCATIONS, WITH THE LAST DISLOCATION APPROXIMATELY 3 WEEKS AGO. A REVISION SURGERY WAS PERFORMED ON (B)(6) 2021 TO CHANGE REFLECTION 28MMID SIZE E XLPE 20 DEG LINER (CASE-(B)(4)) TO CONSTRAINED OPTION AND CHANGE COCR 12/14 FEM HEAD 28 +0 (CASE-(B)(4)). THE CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN.
Patient problems: Joint Dislocation
MAUDE report 13110956 ↗InjurySep 21, 2020Difficult to Insert; Defective Device; Difficult to Insert; Defective Device
IT WAS REPORTED THAT DURING A RIGHT THR PROCEDURE, AFTER IMPLANTING THE OUT CUP 71336450 (REF THREE HOLE SHELL 50MM), LINER 71742850 (REF LNR 28X50-52 20 DEG SZ E) COULDN'T BE IMPLANTED. TRY TO USE THE LINER 71333324 (REF XLPE 28 20 DEG 50-52 E), STILL DIDN'T WORK. TRY TO USE THE OUT CUP OF 71336452 (REF THREE HOLE SHELL 52MM), STILL DID NOT WORK. DUE TO OSTEOPOROSIS OF THE PATIENT, THE OUTER CUP WAS LOOSE AND COULD NOT BE TIGHTENED MANY TIMES, RESULTING IN PARTIAL LOSS OF THE POSTERIOR WALL BONE. FINALLY, THE REINFORCE RING AND BONE CEMENT CUP WERE USED TO COMPLETE THE SURGERY. IN ADDITION, THERE WERE THE BONE GRAFT AND HERCULES BONE CEMENT TO PREVENT INFECTION. A DELAY GREATER THAN 30 MIN WAS REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: Failure of Implant; No Known Impact Or Consequence To Patient; Osteopenia/ Osteoporosis
MAUDE report 10564089 ↗InjuryJul 23, 2020Defective Device; Incomplete or Inadequate Connection; Defective Device; Incomplete or Inadequate Connection
IT WAS REPORTED THAT DURING THR PROCEDURE THE 28 MM LINER WAS NOT COMPATIBLE WITH REFLECTION SHELL SIZE 50. TRIED MULTIPLE TIMES BUT FAILED TO FIT. NO DELAY IN SURGERY TIME SINCE 32 MM LINER WAS AVAILABLE, IT WAS VERY SMOOTH TO FIT IN THE FIRST TRY. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10312357 ↗InjuryOct 30, 2019Unstable; Unstable
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED DUE TO RECURRENT DISLOCATIONS AND INSTABILITY. LINER AND HEAD WERE REMOVED. THIS PATIENT UNDERWENT A CLOSED REDUCTION ON (B)(6) 2011 AND A DISLOCATION ON (B)(6) 2013. IN ADDITION TO THIS THE PATIENT HAD A FALL IN (B)(6) 2013 AND PRESENTED TROCHANTERIC BURSITIS DUE TO THIS INCIDENT.
Patient problems: Injury
MAUDE report 9255835 ↗MalfunctionNov 27, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT THE REFLECTION XLPE 20 DEGREE OVERLAPPED ACETABULAR SIZE E DID NOT GET SEATED TO THE CORRESPONDING 52MM REFLECTION 3 HOLE ACETABULAR SHELL IN A PRIMARY THR. SURGEON STRUGGLED FOR ALMOST 45 MINUTES FOR GETTING IT LOCKED. FINALLY, THEY WERE FORCED TO REMOVE THE TWO SCREWS AND THE ACETABULAR SHELL BECAUSE OF THIS ISSUE (THOUGH THE ACETABULAR SHELL AND SCREWS FIXED PERFECTLY) AND IMPLANTED A SAME SIZE CEMENTED REFLECTION ALL POLY CUP WITH BONE CEMENT.
Patient problems: No Information
MAUDE report 8107736 ↗InjuryNov 14, 2018Unintended Movement; Unintended Movement
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS "ON" 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8070902 ↗InjuryNov 14, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8070262 ↗InjuryNov 14, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8070252 ↗InjuryNov 14, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8070171 ↗InjuryNov 14, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8070157 ↗InjuryNov 14, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8069055 ↗InjuryNov 14, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8068982 ↗InjuryNov 14, 2018Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation; Unspecified Infection
MAUDE report 8068934 ↗InjuryNov 13, 2018Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT PATIENT SUFFERED SEVERAL DISLOCATIONS ON 2017. SPECIFIC DATE AND TREATMENT ARE UNKNOWN.
Patient problems: Injury; Joint Dislocation
MAUDE report 8067853 ↗InjuryFeb 17, 2018Connection Problem; Connection Problem
IT WAS REPORTED THAT DURING THE REFLECTION 50-52, THE ACETABULAR LINER IMPLANT IT COULD NOT LOCK WITH ACETABULAR CUP, THE SURGERY WAS EXTENDED FOR APPROXIMATELY 1 HOUR.
Patient problems: Injury
MAUDE report 7279475 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K002747, K211176. One submission often covers many models, so check the product and lot details in each record.
- Z-0326-2025 · Oct 15, 2024 · Open, ClassifiedTandem Intl Bipolar Cocr Shell/UHMWPE Liner, TI-6AL-4V Retaining Ring, 28MM I.D. 46 MM O.D., REF 71324046, sterile, femoral head bipolar component of the Tandem Bipolar Hip System.
Other Prosthesis, hip, semi-constrained, metal/polymer, cemented devices
- NA 1365-51-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented753 reports
- NA 1365-50-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented412 reports
- ARTICUL/EZE 1365-21-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 recall280 reports
- ARTICUL/EZE 1365-11-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 death262 reports
- LFIT 6260-9-236Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, cemented256 reports
- PINNACLE GRIPTION 1217-32-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented2 deaths239 reports
- ELEOS™ 25002111EOnkos Surgical, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented3 deaths230 reports
- Novation 130-36-52Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented2 recalls124 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.