LEGION 71424004Recalls & reported problems
Smith & Nephew, Inc. · LEGION REVISION TIBIAL BASEPLATE SIZE 4 LEFT · Class 2 · Implant
All models of LEGION (446)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03596010546081), received between Jul 15, 2020 and Jan 19, 2023 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Defective Device” (1 report).
8 other recalls cover devices cleared under the same FDA submission (K043440, K230653); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
- Defective Device1
Patient problems
- Joint Laxity1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJan 19, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, THE PATIENT UNDERWENT A LEFT TKA TWO-STAGE REVISION DUE TO AN UNSPECIFIED INFECTION AS PRIMARY DIAGNOSIS. APPROXIMATELY SIX (6) MONTHS AFTER THIS PROCEDURE, THE PATIENT EXPERIENCED INSTABILITY IN THE REVISED KNEE AND REQUIRED A SECOND REVISION. THE DATES IN WHICH THE INDEX SURGERY, FIRST 2-STAGE REVISION AND SECOND REVISION TOOK PLACE ARE NOT KNOWN. IT IS ALSO UNKNOWN WHICH DEVICES WERE EXPLANTED AND/OR EXCHANGED DURING THE SECOND REVISION. THIS INCIDENT WAS IDENTIFIED IN A RETROSPECTIVE POST-MARKET CLINICAL FOLLOW UP ACTIVITY (PMCF) WHERE ANONYMIZED DATA SUMMARIZING TKA REVISION OUTCOMES WERE GATHERED; THEREFORE, ADDITIONAL INFORMATION IS NOT KNOWN.
Patient problems: Joint Laxity
MAUDE report 16211220 ↗MalfunctionJul 15, 2020Defective Device; Defective Device
IT WAS REPORTED THAT DURING A LEGION REVISION TKA SURGERY ON (B)(6) 2020 IT WAS IMPLANTED A LEGION TIBIAL BASE PLATE. WHEN SURGEON WAS ATTEMPTING TO INSERT THE 3-4 13MM CONSTRAINED POLY IT WOULD NOT LOCK DOWN. A SECOND HIGH FLEX LEGION POLY WAS OPENED AND ATTEMPTED TO BE INSERTED IN AND WOULD NOT LOCK IN AS WELL. EACH POLY WAS INSERTED MULTIPLE TIMES AND POPPED OUT WITH A INSTRUMENT WITH MINIMUM ANTERIOR PRESSURE. IT WAS THEN DECIDED AFTER SEVERAL ATTEMPTS TO LEAVE THE CONSTRAINED INSERT IN DUE TO THE TIBIAL BASE PLATE BEING CEMENTED. KNEE SEEMED STABLE WITHOUT THE POLY MOVING. A DELAY GREATER THAN 30 MIN WAS REPORTED. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 10279601 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K043440, K230653. One submission often covers many models, so check the product and lot details in each record.
- Z-0278-2025 · Oct 2, 2024 · Open, Classifiedsmith&nephew LEIGON OXINIUM CONSTRAINED NONPOROUS FEMORAL COMPONENT, SIZE 4 LEFT, REF 71421164; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POL
- Z-0277-2025 · Oct 2, 2024 · Open, Classifiedsmith&nephew LEIGON OXINIUM CONSTRAINED NONPOROUS FEMORAL COMPONENT, SIZE 3 LEFT, REF 71421163; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POL
- Z-2621-2023 · Aug 31, 2023 · Open, Classifiedsmith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint
- Z-1951-2021 · May 19, 2021 · TerminatedLEGION Posterior Stabilized OXINIUM Femoral Component, REF 71421216, Size 6, Left, Nonporous Femoral Component, A/P 65.5 MM, M/L 73 MM, For Cemented Use Only, ZR-2.5NB,Sterile. Kn
- Z-2538-2019 · Jan 15, 2018 · CompletedLEGION(TM) HEMI STEP TIBIAL WEDGE RK/HK, 5 MM, SIZE 3-4 LT.MDL/RT-LAT, REF 71423432 Product Usage: The constrained knee systems are designed for use in patients in primary and
- Z-0816-2016 · Jan 18, 2016 · TerminatedLEGION(TM) HEMI STEPPED, TIBIAL SCREW-ON WEDGE, REF 71421147, QTY 1, 5 MM, SIZE 5-6 LT-LAT / RT-MDL; Tibial knee prosthesis, augment.
- Z-1820-2009 · Jan 22, 2009 · TerminatedLEGION Pressfit Stem, Straight, 20 MM X 160 MM, REF 71424053, Sterile, Smith & Nephew, Memphis TX 38116. The device is used for Orthopedic Knee Implants.
- Z-1819-2009 · Jan 22, 2009 · TerminatedLEGION Pressfit Stem, Straight, 10 MM X 160 MM, REF 71424043, Sterile, Smith & Nephew, Memphis TX 38116. The device is used for Orthopedic Knee Implants.
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page