Skip to content

LEGION 71424007Recalls & reported problems

Smith & Nephew, Inc. · LEGION REVISION TIBIAL BASEPLATE SIZE 7 LEFT · Class 2 · Implant

All models of LEGION (446)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
2
Deaths reported
0
Injuries reported
2
Recalls naming it
0

Summary

The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 03596010546111), received between Apr 29, 2020 and Apr 11, 2022 — classified as 2 injuries.

The most frequently reported specific device problem is “Patient Device Interaction Problem” (1 report).

8 other recalls cover devices cleared under the same FDA submission (K043440, K230653); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1
  • Patient Device Interaction Problem1

Patient problems

  • Bacterial Infection1
  • Unspecified Infection1

Recent adverse event reports

The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.

  • InjuryApr 11, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, AFTER A TKA SURGERY HAD BEEN PERFORMED ON (B)(6) 2020, THE PATIENT EXPERIENCED AN ARTICULAR INFECTION. THIS ADVERSE EVENT WAS SOLVED BY A REVISION SURGERY ON (B)(6) 2022. CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN.

    Patient problems: Bacterial Infection

    MAUDE report 14074725 ↗
  • InjuryApr 29, 2020Patient Device Interaction Problem; Patient Device Interaction Problem

    IT WAS REPORTED THAT A REVISION SURGERY HAD TO BE PERFORMED DUE TO PROSTHETIC INFECTION. THE LEGION REV TIBIA BASE SIZE 7 LEFT WAS IMPLANTED ON (B)(6) 2017 AND EXPLANTED THE SAME YEAR ON (B)(6) 2017. INITIALLY, IT WAS REPORTED THAT THE INCIDENT WAS FROM ANOTHER MANUFACTURER, THE MISTAKE CAME OUT AND THE REPORT WAS CHANGED WITH THE CORRECT MANUFACTURER AND THE ORIGINAL DETAILS. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.

    Patient problems: Unspecified Infection

    MAUDE report 10012127 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K043440, K230653. One submission often covers many models, so check the product and lot details in each record.

  • Z-0277-2025 · Oct 2, 2024 · Open, Classified
    smith&nephew LEIGON OXINIUM CONSTRAINED NONPOROUS FEMORAL COMPONENT, SIZE 3 LEFT, REF 71421163; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POL
  • Z-0278-2025 · Oct 2, 2024 · Open, Classified
    smith&nephew LEIGON OXINIUM CONSTRAINED NONPOROUS FEMORAL COMPONENT, SIZE 4 LEFT, REF 71421164; PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POL
  • Z-2621-2023 · Aug 31, 2023 · Open, Classified
    smith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint
  • Z-1951-2021 · May 19, 2021 · Terminated
    LEGION Posterior Stabilized OXINIUM Femoral Component, REF 71421216, Size 6, Left, Nonporous Femoral Component, A/P 65.5 MM, M/L 73 MM, For Cemented Use Only, ZR-2.5NB,Sterile. Kn
  • Z-2538-2019 · Jan 15, 2018 · Completed
    LEGION(TM) HEMI STEP TIBIAL WEDGE RK/HK, 5 MM, SIZE 3-4 LT.MDL/RT-LAT, REF 71423432 Product Usage: The constrained knee systems are designed for use in patients in primary and
  • Z-0816-2016 · Jan 18, 2016 · Terminated
    LEGION(TM) HEMI STEPPED, TIBIAL SCREW-ON WEDGE, REF 71421147, QTY 1, 5 MM, SIZE 5-6 LT-LAT / RT-MDL; Tibial knee prosthesis, augment.
  • Z-1820-2009 · Jan 22, 2009 · Terminated
    LEGION Pressfit Stem, Straight, 20 MM X 160 MM, REF 71424053, Sterile, Smith & Nephew, Memphis TX 38116. The device is used for Orthopedic Knee Implants.
  • Z-1819-2009 · Jan 22, 2009 · Terminated
    LEGION Pressfit Stem, Straight, 10 MM X 160 MM, REF 71424043, Sterile, Smith & Nephew, Memphis TX 38116. The device is used for Orthopedic Knee Implants.

Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices

All PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page