JOURNEY 74023261Recalls & reported problems
Smith & Nephew, Inc. · JOURNEY ARTICULAR INSERT BCS STANDARD 5-6 LEFT 9MM · Class 2 · Implant
All models of JOURNEY (566)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 17
- Deaths reported
- 0
- Injuries reported
- 17
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 17 adverse event reports that list this exact device (DI 03596010555205), received between Nov 24, 2017 and Dec 30, 2025 — classified as 17 injuries.
The most frequently reported specific device problem is “Break” (6 reports).
4 other recalls cover devices cleared under the same FDA submission (K042515, K230653); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Break6
- Fracture6
- Adverse Event Without Identified Device or Use Problem3
- Insufficient Device Problem Information3
- Device Dislodged or Dislocated1
Patient problems
- Injury6
- Failure of Implant5
- Pain4
- Insufficient Information2
- Joint Laxity2
- No Clinical Signs, Symptoms or Conditions2
- Arthralgia1
- Bone Fracture(s)1
Recent adverse event reports
The 17 most recent of 17 reports, in the reporter's own words as published by the FDA.
InjuryDec 30, 2025Fracture; Insufficient Device Problem Information; Fracture; Insufficient Device Problem Information
IT WAS REPORTED THAT, AFTER A TKA SURGERY PERFORMED ON (B)(6) 2013, THE PEG OF THE JOURN ART INS BCS STD 5-6 LT 9 FRACTURED. A REVISION SURGERY WAS PERFORMED ON (B)(6) 2025 TO EXPLANT THE FRACTURED IMPLANT AND REPLACE IT FOR S+N IMPLANTS. THE PATIENT IS STILL EXPERIENCING PAIN AND DISCOMFORT AFTER THIS REVISION SURGERY.
Patient problems: Insufficient Information
MAUDE report 23927746 ↗InjurySep 9, 2025Fracture; Fracture
IT WAS REPORTED THAT, AFTER TKA SURGERY HAD BEEN PERFORMED ON (B)(6) 2011, THE PATIENT EXPERIENCED A BREAKAGE OF THE JOURN ART INS BCS STD 5-6 LT 9. THIS ADVERSE EVENT WAS TREATED BY A REVISION SURGERY ON (B)(6) 2025, IN WHICH THE JOURN ART INS BCS STD 5-6 LT 9 WAS REPLACED AND THE PATELLA WAS RESURFACED. CURRENT PATIENT'S HEALTH STATUS IS UNKNOWN.
Patient problems: Insufficient Information
MAUDE report 23001237 ↗InjuryJun 19, 2025Fracture; Fracture
IT WAS REPORTED THAT, AFTER TKA SURGERY HAD BEEN PERFORMED ON (B)(6) 2013, THE PATIENT EXPERIENCED A POST BREAKAGE OF THE INSERT, WHICH CAUSED PAIN, SWELLING AND INSTABILITY. THIS ADVERSE EVENT WAS SOLVED BY REVISION SURGERY ON (B)(6) 2025, IN WHICH THE JOURN ART INS BCS STD 5-6 LT 9 WAS EXPLANTED. CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN. NO FURTHER COMPLICATIONS WERE REPORTED.
Patient problems: Joint Laxity; Pain; Swelling/ Edema
MAUDE report 22293142 ↗InjuryFeb 24, 2025Fracture; Fracture
IT WAS REPORTED THAT, AFTER TKA SURGERY HAD BEEN PERFORMED ON (B)(6) 2006, THE PATIENT EXPERIENCED THE BREAKAGE OF THE ORIGINAL IMPLANT POST. THIS ADVERSE EVENT WAS TREATED BY REVISION SURGERY ON (B)(6) 2025, IN WHICH THE JOURN ART INS BCS STD 5-6 LT 9 WAS EXCHANGED. CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN.
Patient problems: Failure of Implant
MAUDE report 21446022 ↗InjuryJul 11, 2023Fracture; Fracture
IT WAS REPORTED THAT, AFTER A LEFT TKA SURGERY HAD BEEN PERFORMED ON (B)(6) 2011 WITH A JOURNEY BCS SYSTEM, THE PATIENT EXPERIENCED PAIN AND FEMOROTIBIAL DISLOCATION AFTER A FALL ON (B)(6) 2023. A REVISION SURGERY WAS PERFORMED ON (B)(6) 2023 TO ADDRESS THIS ADVERSE EVENT. INTRAOPERATIVELY, IT WAS NOTICED THAT THE JOURN ART INS BCS STD 5-6 LT 9 WAS BROKEN. AS A CONSEQUENCE, THE WHOLE CONSTRUCT HAD TO BE CHANGED. THE PATIENT IS IN GOOD HEALTH CONDITION AFTER THIS PROCEDURE.
Patient problems: Arthralgia; Failure of Implant; Fall; Joint Dislocation; Joint Laxity; Subluxation
MAUDE report 17299298 ↗InjuryApr 4, 2022Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT, AFTER A TOTAL KNEE ARTHROPLASTY WAS PERFORMED, THE PATIENT EXPERIENCED PAIN. THIS ADVERSE EVENT WAS TREATED WITH A REVISION SURGERY ON (B)(6) 2022, IN WHICH A JOURNEY ARTICULAR INSERT BCS STANDARD 5-6 LEFT 9MM WAS EXPLANTED AND THE PATELLA WAS RESURFACED. PATIENT'S CURRENT HEALTH STATUS IS UNKNOWN.
Patient problems: Pain
MAUDE report 13996102 ↗InjurySep 14, 2021Break; Break
IT WAS REPORTED THAT, AFTER A PRIMARY SURGERY HAD BEEN PERFORMED ON (B)(6) 2011, ONE JOURN ART INS BCS STD 5-6 LT 9 BROKE. THIS ADVERSE EVENT WAS SOLVED BY A REVISION SURGERY ON (B)(6) 2021. CURRENT HEALTH STATUS OF PATIENT IS UNKNOWN.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 12471662 ↗InjuryMay 18, 2021Break; Break
IT WAS REPORTED THAT, AFTER A TKA SURGERY HAD BEEN PERFORMED ON (B)(6) 2009, A JOURN ART INS BCS STD 5-6 LT 9 WAS BROKEN. THE ADVERSE EVENT WAS ADDRESSED WITH A REVISION SURGERY ON AN UNKNOWN DATE. THE CONDITION OF THE PATIENT IS UNKNOWN.
Patient problems: Failure of Implant
MAUDE report 11842112 ↗InjuryDec 2, 2020Break; Break
GT HOLD 12 2 20IT WAS REPORTED THAT SURGEON CONTACTED REPRESENTATIVE ON (B)(6) 2020 TELLING THAT PATIENT HAD FALLEN AND THAT THE LEFT TOTAL REPLACEMENT IS NOW UNSTABLE. A REVISION SURGERY WAS BOOKED FOR THE REMOVAL OF BROKEN INSERT AND THE INSERTION OF THE NEW ARTICULATE INSERT FOR (B)(6) 2020.
Patient problems: Failure of Implant; No Clinical Signs, Symptoms or Conditions
MAUDE report 10931469 ↗InjuryAug 3, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT THE PATIENT FELT A POP BENDING OVER AND WAS SEEN IN THE ER FOR WHAT WAS BELIEVED TO BE A DISLOCATED KNEE OR POSSIBLE INSERT POST-FRACTURE. THE PATIENT WAS TAKEN TO SURGERY 2 DAYS LATER FOR AN INSERT EXCHANGE. THE INSERT POST WAS INTACT, BUT A THICKER INSERT WAS PLACED TO IMPROVE STABILITY. PATIENT OUTCOME IS UNKNOWN. ALL AVAILABLE INFORMATION HAS BEEN DISCLOSED. IF ADDITIONAL INFORMATION SHOULD BECOME AVAILABLE, A SUPPLEMENTAL REPORT WILL BE SUBMITTED ACCORDINGLY.
Patient problems: Injury; Pain
MAUDE report 10358076 ↗InjuryOct 14, 2019Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED A REVISION SURGERY WAS PERFORMED DUE TO PAIN AND INSTABILITY. AT FIRST IT WAS THOUGHT THAT THE PEG WAS BROKEN BUT WHEN OPENING THE KNEE AND PERFORMING FURTHER INSPECTION, SURGEON DETERMINED THAT PATIENT HAD DEVELOPED OSTEOPOROSIS AND THE FEMORAL BONE COLLAPSED AS A RESULT. THIS CAUSED THE PAIN AND INSTABILITY. PROSTHESIS WAS REMOVED AND A LEGION REVISION WAS ON HAND TO COMPLETE IN 1 STAGE.
Patient problems: Pain
MAUDE report 9187417 ↗InjuryJun 16, 2019Device Dislodged or Dislocated; Device Dislodged or Dislocated
IT WAS REPORTED THAT A DAMAGED JOURNEY 1 INSERT WAS REMOVED FROM THE PATIENT AND THAT THE POST WAS DISASSOCIATED FROM THE MAIN BODY OF THE INSERT RESULTING IN INSTABILITY. JOURNEY REVISION INSERT WAS IMPLANTED AND STABILITY WAS RESTORED.
Patient problems: Injury
MAUDE report 8702581 ↗InjuryApr 16, 2019Fracture; Fracture
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED DUE TO A BROKEN INSERT.
Patient problems: Injury
MAUDE report 8520420 ↗InjuryFeb 11, 2019Break; Break
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED DUE TO THE INSERT BROKE.
Patient problems: Injury
MAUDE report 8329135 ↗InjuryMay 13, 2018Break; Break
IT WAS REPORTED THAT A CASE WAS BOOKED AS A LEFT JOURNEY INSERT EXCHANGE. ON DISCUSSION WITH THE SURGEON PRIOR TO THE START OF THE SURGERY, HE INDICATED THAT THE PATIENT HAD PREVIOUSLY HAD A KNEE ARTHROSCOPY OF THE SAME KNEE AND THE POST OF THE POLYETHYLENE HAD BROKEN OFF AND BEEN REMOVED. DURING THE INSERT EXCHANGE SURGERY THE SURGEON REMOVED THE POLYETHYLENE (SZ 5-6 9MM) USING A BRISTOW AND MALLET. HE PROCEEDED TO REMOVED ANY TISSUE THAT MAY INHIBIT THE INSERTION OF THE NEW POLYETHYLENE AND TRIALLED WITH AN INSERT 2MM THICKER THAN THE ORIGINAL SIZE.
Patient problems: Injury
MAUDE report 7509699 ↗InjuryFeb 19, 2018Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED DUE TO THE PIN BROKE.
Patient problems: Bone Fracture(s); Injury
MAUDE report 7280880 ↗InjuryNov 24, 2017Break; Break
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED DUE TO INSTABILITY. THE JOURNEY INSERT WAS FOUND BROKE.
Patient problems: Failure of Implant
MAUDE report 7057939 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K042515, K230653. One submission often covers many models, so check the product and lot details in each record.
- Z-2621-2023 · Aug 31, 2023 · Open, Classifiedsmith&nephew LEGION OXINUM POSTERIOR STABILIZED NONPOROUS FERMOAL COMPONENT, SIZE 5N, LEFT, NARROW, REF 71421265; knee joint
- Z-0001-2019 · Jun 13, 2018 · Open, ClassifiedJourney BCS Knee CoCr Femoral Components, Catalog Numbers: 74021210, 74021211, 74021212, 74021213, 74021214, 74021215, 74021216, 74021217, 74021218, 74021219, 74021220, 74021221, 7
- Z-0002-2019 · Jun 13, 2018 · Open, ClassifiedJOURNEY BCS OXINIUM Knee Femoral Components, Catalog Numbers: 74021110, 74021111, 74021112, 74021113, 74021114, 74021115, 74021116, 74021117, 74021118, 74021119, 74021120, 7402112
- Z-0003-2019 · Jun 13, 2018 · Open, ClassifiedJOURNEY BCS Knee Conventional Polyethylene Inserts: 74023111, 74023112, 74023113, 74023114, 74023115, 74023116, 74023117, 74023118, 74023121, 74023122, 74023123, 74023124, 7402312
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page