EMPERION 71291301Recalls & reported problems
Smith & Nephew, Inc. · EMPERION 13 STEM PRIMARY SO · Class 2 · Implant
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 03596010561480), received between Apr 11, 2017 and Nov 12, 2021 — classified as 5 injuries.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Fracture2
- Break1
- Device Operates Differently Than Expected1
- Insufficient Device Problem Information1
- Mechanical Problem1
- Unstable1
Patient problems
- Failure of Implant2
- Injury2
- Bone Fracture(s)1
- Limited Mobility Of The Implanted Joint1
- No Code Available1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
InjuryNov 12, 2021Break; Break
IT WAS REPORTED THAT, A REVISION SURGERY WAS PERFORMED ON (B)(6) 2021 DUE TO THE FRACTURE OF AN EMP 13 STEM PRIMARY SO IMPLANTED 10 YEARS AGO AND REVISED TO A LONG STEM ECHELON. DURING THE SURGERY, THE EMP 13 STEM PRIMARY SO, THE EMP13 SLV SM CONE 1 SPOUT AND THE BIOLOX DELTA HEAD 36 MM 12/14 M / +4 WERE EXPLANTED. EXTENSIVE OSTEOTOMIES WERE PERFORMED DUE TO THE SIGNIFICANT INGROWTH OF BONE ONTO PROXIMAL SLEEVE. MOREOVER, THE SHELL AND THE CERAMIC LINER WERE LEFT UNTOUCHED. THE EXPLANTED DEVICES ARE NOT ABLE TO BE EVALUATED. NO FURTHER INFORMATION AVAILABLE REGARDING THE POST OPERATIVE CONDITION OF PATIENT IS AVAILABLE.
Patient problems: Failure of Implant
MAUDE report 12804686 ↗InjuryJan 27, 2020Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT A REVISION SURGERY WAS PERFORMED DUE TO AN EMPERION STEM FAILURE. THE SURGEON APPLIED A BENDING FORCE AS WOULD BE PRESENT WITH WEIGHTBEARING AND FELT THAT HE COULD SEE A SMALL AMOUNT OF GAPPING AND OPENING AT THE LATERAL ASPECT OF THE STEM CONSISTENT WITH A FATIGUE FAILURE.
Patient problems: Injury
MAUDE report 9633877 ↗InjuryJun 2, 2018Fracture; Fracture
DR REVISED AN EMPERION STEM THAT HAD BEEN IMPLANTED APPROXIMATELY 9 YEARS AGO; THE STEM HAD FRACTURED INSIDE THE TOP OF THE CONE.
Patient problems: Bone Fracture(s)
MAUDE report 7564010 ↗InjuryJun 21, 2017Fracture; Fracture
IT WAS REPORTED IN A PUBLICATION THAT A PATIENT HAD A REVISION HIP SURGERY DUE TO FRACTURE OF THE STEM. NO FURTHER INFORMATION WAS AVAILABLE.
Patient problems: Injury
MAUDE report 6656102 ↗InjuryApr 11, 2017Mechanical Problem; Unstable; Device Operates Differently Than Expected
IT WAS REPORTED THAT PATIENT UNDERWENT A REVISION OF LEFT THA DUE TO MECHANICAL FAILURE OF THE IMPLANT, AS REPORTED DUE TO ROTARY INSTABILITY OF FEMORAL COMPONENT AT THE MOSE STEM/SLEEVE JUNCTION. ALL COMPONENTS EXCEPT FOR ACETABULAR SHELL WERE REVISED.
Patient problems: Failure of Implant; Limited Mobility Of The Implanted Joint; No Code Available
MAUDE report 6479562 ↗
Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices
- Novation 130-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls156 reports
- Novation 130-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls79 reports
- CORAIL 3L92511Depuy (Ireland) · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate158 reports
- Acumatch A Series 138-36-29Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate3 recalls1 report
- Novation 136-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls43 reports
- Novation 130-32-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls33 reports
- Novation 132-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls26 reports
- Novation 136-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls22 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.