Skip to content

R3 71332762Recalls & reported problems

Smith & Nephew, Inc. · R3 0 DEGREE XLPE ACETABULAR LINER 36MM INNER DIAMETER X OUTER DIAMETER 62MM · Class 2 · Implant

Adverse event reports
5
Deaths reported
0
Injuries reported
4
Recalls naming it
0

Summary

The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 03596010598035), received between Nov 21, 2018 and May 13, 2024 — classified as 4 injuries, 1 malfunction.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (3 reports).

3 other recalls cover devices cleared under the same FDA submission (K113848, K211176); they may or may not involve this specific model.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 1 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information3
  • Adverse Event Without Identified Device or Use Problem1
  • Delivered as Unsterile Product1
  • Device Dislodged or Dislocated1

Patient problems

  • Unspecified Infection3
  • Joint Dislocation1
  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.

  • InjuryMay 13, 2024Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem; Device Dislodged or Dislocated; Adverse Event Without Identified Device or Use Problem

    IT WAS REPORTED THAT, AFTER A THR SURGERY WAS PERFORMED ON AN UNKNOWN DATE, THE PATIENT EXPERIENCED FIVE DISLOCATIONS OF THE HIP. THIS ADVERSE EVENT WAS TREATED BY A REVISION SURGERY ON (B)(6) 2024, IN WHICH A R3 0 DEG XLPE ACET LNR 36MM X 62MM WAS EXCHANGED. PATIENT'S CURRENT HEALTH STATUS IS UNKNOWN.

    Patient problems: Joint Dislocation

    MAUDE report 19296531 ↗
  • MalfunctionDec 7, 2023Delivered as Unsterile Product; Delivered as Unsterile Product

    IT WAS REPORTED THAT, DURING THR SURGERY, WHEN OPENING AN R3 0 DEG XLPE ACET LNR 36MM X 62MM, THE IMPLANT FELL ONTO THE FLOOR. IT WAS NOTICED THAT THE PACKAGING HAD A SPLIT IN THE INTERNAL AND EXTERNAL PLASTIC PACKAGING, THE PLASTIC PACKAGING WAS SEALED AT BOTH ENDS, HOWEVER THE SPLIT WAS ON THE SIDE EDGE OF THE PACKAGING. THE EXTERNAL BOX APPEARED TO BE SEALED AND UNOPENED. THE PROCEDURE WAS RESUMED, AFTER A NON-SIGNIFICANT DELAY, WITH A S+N BACK-UP DEVICE. NO INJURY WAS REPORTED AS A CONSEQUENCE OF THIS ISSUE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 18287575 ↗
  • InjuryNov 21, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT AN IR DRAIN WAS DONE TO THE PATIENT DUE TO PERSISTENT INFECTION.

    Patient problems: Unspecified Infection

    MAUDE report 8096891 ↗
  • InjuryNov 21, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT A MEDICAL INTERVENTION WAS DONE WITH THE PLACEMENT OF ANTIBIOTIC IMPREGNATED BEADS. DEVICES WERE RETAINED.

    Patient problems: Unspecified Infection

    MAUDE report 8096093 ↗
  • InjuryNov 21, 2018Insufficient Device Problem Information; Insufficient Device Problem Information

    IT WAS REPORTED THAT AN ASPIRATION OF THE LEFT HIP WAS PERFORMED DUE TO A THIGH SEROMA AND PROSTHETIC JOINT INFECTION. OPEN IRRIGATION AND DEBRIDEMENT WAS DONE.

    Patient problems: Unspecified Infection

    MAUDE report 8095923 ↗

Recalls under the same FDA submission

These recalls involve devices cleared under K113848, K211176. One submission often covers many models, so check the product and lot details in each record.

  • Z-0326-2025 · Oct 15, 2024 · Open, Classified
    Tandem Intl Bipolar Cocr Shell/UHMWPE Liner, TI-6AL-4V Retaining Ring, 28MM I.D. 46 MM O.D., REF 71324046, sterile, femoral head bipolar component of the Tandem Bipolar Hip System.
  • Z-1929-2013 · May 29, 2013 · Terminated
    R3 (TM) XLPE ACETABULAR LINER UHMWPE, 20o OVERHANG, 36 MM ID, 60 MM OD, QTY: (1), STERILE H2O2, REF 71335760. Orthopaedic.
  • Z-1928-2013 · May 29, 2013 · Terminated
    R3 (TM) XLPE ACETABULAR LINER UHMWPE, 20o OVERHANG, 36 MM ID, 62 MM OD, QTY: (1), STERILE H2O2, REF 71335762. Orthopaedic.

Other Prosthesis, hip, semi-constrained, metal/polymer, cemented devices

All Prosthesis, hip, semi-constrained, metal/polymer, cemented devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.