ROI-C MC1320PRecalls & reported problems
LDR Spine Usa, Inc. · ROI-C IMPLANT 14X15.5 H4.5 · Class 2
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 03662663016124), received between Feb 2, 2021 and Nov 22, 2023 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Fracture” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Fracture2
- Device Slipped1
- Malposition of Device1
- Migration1
Patient problems
- No Clinical Signs, Symptoms or Conditions2
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 22, 2023Fracture; Device Slipped; Fracture; Device Slipped
IT WAS REPORTED THAT AN ROI-C CAGE WOBBLED IN THE DISC SPACE WHEN THE FIRST ANCHORING PLATE WAS INTRODUCED. THE CAGE WAS REMOVED AND WAS FOUND TO BE BROKEN. A NEW CAGE WAS USED TO COMPLETE THE PROCEDURE. THERE WAS A 15-MINUTE DELAY WITHOUT PATIENT IMPACTS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 18191924 ↗MalfunctionMar 6, 2023Malposition of Device; Migration; Malposition of Device; Migration
IT WAS REPORTED THAT AN ROI-C CAGE WAS NOT WELL-POSITIONED THEN IT MOVED ANTERIORLY AND INTO THE CORTICAL RIM OF THE VERTEBRAL BODY WHILE THE SUPERIOR PLATE WAS BEING INSTALLED. THE CAGE WAS REMOVED AND REPLACED TO COMPLETE THE PROCEDURE. THERE WAS A 10 MINUTE DELAY AND NO IMPACT TO THE PATIENT.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 16484877 ↗MalfunctionFeb 2, 2021Fracture; Fracture
IT WAS REPORTED THAT A PIECE OF ROI-C CAGE BROKE OFF WHILE ANCHORING PLATES WERE BEING HAMMERED INTO THE CAGE. THE CAGE WAS REMOVED AND REPLACED. THERE WAS NO REPORTED PATIENT HARM.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 11268011 ↗
Other Intervertebral Fusion Device With Bone Graft, Cervical devices
- EIT CIF cage CUI8070SEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall4 reports
- ROI-C MC1005TLDR Spine Usa, Inc. · Intervertebral Fusion Device With Bone Graft, Cervical54 reports
- EIT CIF cage CUI8060LEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall1 report
- CONSTRUX - MINI Ti 37-7206SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8007SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI PTC 37-4211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI PTC 37-5211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8105SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.