ORION System 1SOPT00009Recalls & reported problems
Bizlink Robotic Solutions France S.A.S. · Electro-mechanical robotic arm for patient positioning in radiotherapy and medical imaging. · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.
- Adverse event reports
- 0
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 1
Summary
No MAUDE adverse event reports in our data reference this device identifier directly.
1 FDA recall record name this device's identifier, 1 still open.
1 other recall cover devices cleared under the same FDA submission (K160518); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Recalls naming this device
- Oct 6, 2023Open, Classified
Users of the patient positioning system ORION System can be faced with a sudden short-term acceleration or with an unintended short-distance movement when the movements are again allowed after an unforeseen interruption signal of motion may result in a collision of the patient with another stationary component of the treatment room.
Z-0399-2024 · Root cause: Software design · Recall details · FDA record ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K160518. One submission often covers many models, so check the product and lot details in each record.
- Z-0398-2024 · Oct 6, 2023 · Open, ClassifiedORION System with software OSS v6.0 and OSS v7.0- An electro-mechanical robotic arm for patient positioning in Radiation Therapy, Radiology, or Radiology image-guided treatment env
Other Couch, Radiation Therapy, Powered devices
- HexaPOD P10603-1003C-Medical Intelligence GmbH · Couch, Radiation Therapy, Powered1 recall0 reports
- ORION System 1SOPT00003Bizlink Robotic Solutions France S.A.S. · Couch, Radiation Therapy, Powered1 recall0 reports
- Proutra™ MT6XSM1.7.3Medtec, Inc. · Couch, radiation therapy, powered1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026 · each recall links to the FDA recall notice
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page