NA 901-0048Recalls & reported problems
Stryker GmbH · Cannulated T25 Screwdriver Shaft · Class 1
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 9
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 03700586902947), received between Aug 15, 2024 and Aug 22, 2024 — classified as 2 injuries, 7 malfunctions.
The most frequently reported specific device problem is “Device Difficult to Setup or Prepare” (9 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Device Difficult to Setup or Prepare9
Patient problems
- No Clinical Signs, Symptoms or Conditions9
Recent adverse event reports
The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.
MalfunctionAug 22, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT WHERE THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE 1.8MM) ARE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION, THIS HAS HAPPENED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INITIALLY IN A CASE RESULTING IN ANOTHER KIT BEING USED AND EXTENDED UNDER ANESTHETIC TIME. SURGERY WAS COMPLETED BY USING CHARLOTTE MUC KIT. INQUIRY (B)(6) - EVENT DATE (B)(6) 2024 SATURDAY ¿ CASE PROCEEDED WITH CHARLOTTE MUC. 4 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20031025 ↗MalfunctionAug 22, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT WHERE THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE 1.8MM) ARE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION, THIS HAS HAPPENED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INITIALLY IN A CASE RESULTING IN ANOTHER KIT BEING USED AND EXTENDED UNDER ANESTHETIC TIME. SURGERY WAS COMPLETED BY USING CHARLOTTE MUC KIT. INQUIRY PI (B)(4) - EVENT DATE 07/20/2024 SATURDAY ¿ CASE PROCEEDED WITH (B)(6). 4 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20030844 ↗MalfunctionAug 21, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT, THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE, 1.8MM) WERE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION. THIS ISSUE HAS OCCURRED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INTRA-OPERATIVELY, CAUSING THE SURGERY TO BE FULLY CANCELED WHILE THE PATIENT WAS ALREADY PREPARED IN THE ROOM. INQUIRY PI (B)(6) ¿ EVENT DATE (B)(6) 2024 TUESDAY. CASE CANCELLED. 2 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20018243 ↗InjuryAug 21, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT, THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE, 1.8MM) WERE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION. THIS ISSUE HAS OCCURRED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INTRA-OPERATIVELY, CAUSING THE SURGERY TO BE FULLY CANCELED WHILE THE PATIENT WAS ALREADY PREPARED IN THE ROOM. INQUIRY (B)(4) ¿ EVENT DATE 07/23/2024 TUESDAY. CASE CANCELLED. 2 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20011061 ↗MalfunctionAug 20, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT, THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE, 1.8MM) WERE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION. THIS ISSUE HAS OCCURRED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INTRA-OPERATIVELY, CAUSING THE SURGERY TO BE FULLY CANCELED WHILE THE PATIENT WAS ALREADY PREPARED IN THE ROOM. INQUIRY (B)(4) - EVENT DATE 07/23/2024. CASE CANCELED. 3 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20005349 ↗InjuryAug 20, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT, THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE, 1.8MM) WERE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION. THIS ISSUE HAS OCCURRED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INTRA-OPERATIVELY, CAUSING THE SURGERY TO BE FULLY CANCELED WHILE THE PATIENT WAS ALREADY PREPARED IN THE ROOM. INQUIRY PI 3703869 - EVENT DATE 07/23/2024. CASE CANCELED. 3 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 20004105 ↗MalfunctionAug 15, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT WHERE THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE 1.8MM) ARE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION, THIS HAS HAPPENED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INITIALLY IN A CASE RESULTING IN ANOTHER KIT BEING USED AND EXTENDED UNDER ANESTHETIC TIME. SURGERY WAS COMPLETED BY USING COMPETITOR KIT. INQUIRY PI (B)(6) - EVENT DATE (B)(6) 2024 FRIDAY. CASE COMPLETED WITH COMPETITOR KIT. 1 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19997082 ↗MalfunctionAug 15, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT WHERE THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE 1.8MM) ARE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION, THIS HAS HAPPENED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INITIALLY IN A CASE RESULTING IN ANOTHER KIT BEING USED AND EXTENDED UNDER ANESTHETIC TIME. SURGERY WAS COMPLETED BY USING COMPETITOR KIT. INQUIRY (B)(4) EVENT DATE 07/19/2024 FRIDAY. CASE COMPLETED WITH COMPETITOR KIT. 1 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19997081 ↗MalfunctionAug 15, 2024Device Difficult to Setup or Prepare; Device Difficult to Setup or Prepare
AS REPORTED BY THE COMPANY REP: DURING MULTIPLE CASES USING THE 6.5 AUTOFIX LOAN KIT WHERE THE K-WIRES PROVIDED (OR ONES OF THE SAME SIZE 1.8MM) ARE NOT FITTING THROUGH THE AUTOFIX INSTRUMENTATION, THIS HAS HAPPENED IN MULTIPLE INSTRUMENT SETS. THE ISSUE WAS DISCOVERED INITIALLY IN A CASE RESULTING IN ANOTHER KIT BEING USED AND EXTENDED UNDER ANESTHETIC TIME. SURGERY WAS COMPLETED BY USING COMPETITOR KIT. INQUIRY PI 3697784 - EVENT DATE(B)(6) 2024 FRIDAY. CASE COMPLETED WITH COMPETITOR KIT. 1 OUT OF 4.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19997078 ↗
Other SCREWDRIVER devices
- DELTA XTEND 2307-92-003Depuy (Ireland) · SCREWDRIVER751 reports
- EXPEDIUM 279712400Medos International Sàrl · SCREWDRIVER551 reports
- NA 314.467Synthes GmbH · SCREWDRIVER498 reports
- N/A 5584111Medtronic Sofamor Danek, Inc. · SCREWDRIVER492 reports
- QUICKSET 2274-47-000Depuy (Ireland) · SCREWDRIVER487 reports
- NA 03.130.010Synthes GmbH · SCREWDRIVER1 recall422 reports
- QUICKSET 2274-63-000Depuy (Ireland) · SCREWDRIVER404 reports
- EVOS 71175072Smith & Nephew, Inc. · SCREWDRIVER336 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page