Humelock II Cemented Reversible Shoulder 104-0806Recalls & reported problems
Fx Solutions · HUMERAL CUP STANDARD PE/TA6V Ø40/+6 · Class 2 · Implant
All models of Humelock II Cemented Reversible Shoulder (23)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 15
- Deaths reported
- 0
- Injuries reported
- 15
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 03701037300138), received between Mar 25, 2022 and Jul 6, 2026 — classified as 15 injuries.
The most frequently reported specific device problem is “Device Dislodged or Dislocated” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem9
- Appropriate Device Problem Term/Code Not Available2
- Device Dislodged or Dislocated2
- Microbial Contamination of Device1
- Migration1
Patient problems
- Joint Dislocation6
- Medical device site infection4
- Joint Laxity3
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1
- Insufficient Information1
Recent adverse event reports
The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.
InjuryJul 6, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS REVISED DUE TO AN INFECTION ON (b)(6) 2026. THE IMPLANTATION DATE WAS ON (b)(6) 2026. A CUP, A GLENOSPHERE, A GLENOID BASEPLATE, SCREWS AND A STEM WERE EXPLANTED. A CUP, A GLENOSPHERE, A GLENOID BASEPLATE, SCREWS AND A STEM WERE IMPLANTED.
Patient problems: Medical device site infection
MAUDE report 25715681 ↗InjuryMar 2, 2026Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS REVISED DUE TO DISLOCATION ON (B)(6) 2026. THE IMPLANTATION DATE WAS ON (B)(6) 2020. A CUP AND A GLENOSPHERE WERE EXPLANTED. A CUP AND A GLENOSPHERE WERE IMPLANTED.
Patient problems: Joint Dislocation
MAUDE report 24480827 ↗InjuryApr 4, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS REVISED DUE TO DISLOCATION ON (B)(6) 2025. THE IMPLANTATION DATE WAS ON (B)(6) 2025.A CUP WAS EXPLANTED. A CUP WAS IMPLANTED.
Patient problems: Joint Dislocation
MAUDE report 21772637 ↗InjurySep 6, 2024Migration; Migration
THE PATIENT WAS REVISED DUE TO A DISMANTLING ON (B)(6) 2024. THE IMPLANTATION DATE WAS ON (B)(6) 2021. A CUP, A GLENOSPHERE, A METAGLENE AND SCREWS WERE EXPLANTED. A CUP, A GLENOSPHERE, A METAGLENE, A POST EXTENSION AND SCREWS WERE IMPLANTED.
Patient problems: Joint Laxity
MAUDE report 20154883 ↗InjuryJun 27, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REVISION OCCURRED APPROXIMATELY 13 MONTHS AFTER THE PRIMARY SURGERY WHICH OCCURRED ON (B)(6) 2023. NO FALL OR OTHER TRAUMA REPORTED. REVISION WAS A POLY SWAP DUE TO INFECTION. 40 MM + 6 STANDARD HUMERAL CUP EXPLANTED AND REPLACED WITH AN IDENTICAL PART.
Patient problems: Medical device site infection
MAUDE report 19626943 ↗InjuryMay 3, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS REVISED DUE TO AN INFECTION ON (B)(6) 2024. THE IMPLANTATION DATE WAS ON (B)(6) 2024. A CUP AND A GLENOSPHERE WERE EXPLANTED. A CUP AND A GLENOSPHERE WERE IMPLANTED.
Patient problems: Medical device site infection
MAUDE report 19236298 ↗InjuryApr 5, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REVISION OCCURRED APPROXIMATELY 7 WEEKS AFTER THE PRIMARY SURGERY WHICH OCCURRED ON (B)(6) 2024. THE SYSTEM IS A HYBRID OF FX V135 STEM AND CUP ON THE HUMERAL SIDE AND A COMPETITOR'S PRODUCTS ON THE GLENOID SIDE. NO FALL OR OTHER TRAUMA REPORTED. REVISION OCCURRED DUE TO DISLOCATION OF UNKNOWN CAUSE. 40 MM + 6 STANDARD HUMERAL CUP EXPLANTED AND REPLACED WITH 40 MM + 9 STABILITY HUMERAL CUP.
Patient problems: Joint Dislocation
MAUDE report 19053586 ↗InjuryNov 9, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
THE PATIENT WAS REVISED DUE TO DISLOCATION ON (B)(6) 2023. THE IMPLANTATION DATE WAS ON (B)(6) 2019. A CUP WAS EXPLANTED. A CUP AND A HUMERAL SPACER WERE IMPLANTED.
Patient problems: Joint Dislocation
MAUDE report 18101133 ↗InjuryNov 3, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REVISION OCCURRED APPROXIMATELY 3 WEEKS AFTER PRIMARY SURGERY FOR DISLOCATION. PRIMARY SURGERY OCCURRED ON (B)(6) 2023. NO FALL OR OTHER TRAUMA REPORTED. 40 MM + 6 STANDARD HUMERAL CUP EXPLANTED AND REPLACED WITH A 40 MM + 3 STABILITY HUMERAL CUP AND 9 MM SPACER. POST REVISION, IT WAS DISCOVERED THAT THE PATIENT HAD AN UNDERLYING INFECTION.
Patient problems: Joint Dislocation
MAUDE report 18066118 ↗InjuryOct 18, 2023Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
DISLOCATION OCCURRED APPROXIMATELY TWO MONTHS AFTER INITIAL IMPLANTATION DATE. NO FALL OR TRAUMA EVIDENT. STANDARD 40 MM + 6 HUMERAL CUP AND 9 MM HUMERAL SPACER EXPLANTED. REPLACEMENT WITH 40 MM + 9 HUMERAL CUP AND 9 MM HUMERAL SPACER.
Patient problems: Joint Dislocation
MAUDE report 17959785 ↗InjuryJul 11, 2023Microbial Contamination of Device; Microbial Contamination of Device
THE PATIENT WAS REVISED DUE TO AN INFECTION ON (B)(6) 2023. THE IMPLANTATION DATE WAS ON (B)(6) 2023. A CUP WAS EXPLANTED. A CUP WAS IMPLANTED.
Patient problems: Medical device site infection
MAUDE report 17297110 ↗InjuryJun 7, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated
THE PATIENT WAS REVISED DUE TO DISMANTLING ON (B)(6) 2023. THE IMPLANTATION DATE WAS ON (B)(6) 2022. A CUP AND A GLENOSPHERE WERE EXPLANTED. A CUP AND A GLENOSPHERE WERE IMPLANTED.
Patient problems: Joint Laxity
MAUDE report 17077137 ↗InjuryMay 23, 2023Device Dislodged or Dislocated; Device Dislodged or Dislocated
THE PATIENT WAS REVISED DUE TO DISMANTLING ON (B)(4) 2023. THE IMPLANTATION DATE WAS ON (B)(6) 2023. A CUP WAS EXPLANTED. A CUP WAS IMPLANTED.
Patient problems: Joint Laxity
MAUDE report 16982247 ↗InjuryApr 4, 2022Appropriate Device Problem Term/Code Not Available
THE PATIENT WAS REVISED ON (B)(6) 2022 DUE TO DISMANTLING. APPROXIMATELY 9 MONTHS AFTER THE FIRST SURGERY. THE SURGEON EXPLANTED 1 CENTERED GLENOSPHERE AND 1 HUMERAL CUP Ø40+6. THE SURGEON IMPLANTED 1 CENTERED GLENOSPHERE AND 1 HUMERAL CUP Ø40+6.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 13994894 ↗InjuryMar 25, 2022Appropriate Device Problem Term/Code Not Available
THE PATIENT WAS REVISED ON (B)(6) 2022 FOR CUFF TEAR. APPROXIMATELY 35 DAYS AFTER THE FIRST SURGERY. THE SURGEON EXPLANTED 1 HUMERAL CUP Ø40+6. THE SURGEON IMPLANTED 1 HUMERAL CUP 40+9.
Patient problems: Insufficient Information
MAUDE report 13901030 ↗
Other Shoulder Prosthesis, Reverse Configuration devices
- DJO SURGICAL 508-36-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration508 reports
- DJO SURGICAL 508-32-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration433 reports
- DJO SURGICAL 508-32-103Encore Medical, L.P. · shoulder prosthesis, reverse configuration421 reports
- DJO SURGICAL 509-00-036Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall259 reports
- DJO SURGICAL 508-32-104Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall203 reports
- DJO SURGICAL 509-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration233 reports
- DELTA XTEND 130760000Depuy (Ireland) · shoulder prosthesis, reverse configuration223 reports
- DJO SURGICAL 508-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration122 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.