FX V135 Shoulder Prosthesis 202-0906Recalls & reported problems
Fx Solutions · FX V135 HUMERAL CUP 135/145° STABILITY PE/TA6V Ø32 +6 · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03701037315378), received between Jul 29, 2025 and Jul 29, 2025 — classified as 1 injury.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Adverse Event Without Identified Device or Use Problem1
Patient problems
- Implant Pain1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryJul 29, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
REVISION OCCURRED APPROXIMATELY 10 MONTHS AFTER THE PRIOR REVISION SURGERY, WHICH OCCURRED ON (B)(6) 2024. THE PRIMARY SURGERY OCCURRED ON (B)(6) 2022. NO FALL OR OTHER TRAUMA REPORTED. REVISION OCCURRED DUE TO PAIN AT THE IMPLANT SITE. THE SURGEON BELIEVED THE STEM MIGHT BE LOOSE BASED ON PRE-OPERATIVE ASSESSMENT, BUT THE STEM WAS FULLY SET WHEN CHECKED DURING THE SURGERY. A 32 MM + 6 HUMERAL STABILITY CUP, AND A 15 MM LOCKING SCREW WERE EXPLANTED. THESE ITEMS WERE REPLACED WITH AN IDENTICAL CUP.
Patient problems: Implant Pain
MAUDE report 22650174 ↗
Other Shoulder Prosthesis, Reverse Configuration devices
- DJO SURGICAL 508-36-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration508 reports
- DJO SURGICAL 508-32-101Encore Medical, L.P. · shoulder prosthesis, reverse configuration433 reports
- DJO SURGICAL 508-32-103Encore Medical, L.P. · shoulder prosthesis, reverse configuration421 reports
- DJO SURGICAL 509-00-036Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall259 reports
- DJO SURGICAL 508-32-104Encore Medical, L.P. · shoulder prosthesis, reverse configuration1 recall203 reports
- DJO SURGICAL 509-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration233 reports
- DELTA XTEND 130760000Depuy (Ireland) · shoulder prosthesis, reverse configuration223 reports
- DJO SURGICAL 508-00-032Encore Medical, L.P. · shoulder prosthesis, reverse configuration122 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page