FX V135 Shoulder Prosthesis 204-0906Recalls & reported problems

Fx Solutions · FX V135 HUMERAL CUP 135/145° STABILITY PE/TA6V Ø40 +6 · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 03701037315439), received between Feb 16, 2024 and Oct 24, 2025 — classified as 3 injuries.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 1 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 1 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem3

Patient problems

  • Joint Dislocation3

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 24, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION OCCURRED APPROXIMATELY 7 WEEKS AFTER THE PRIMARY SURGERY, WHICH OCCURRED ON (B)(6) 2025. NO FALL OR OTHER TRAUMA REPORTED. REVISION OCCURRED DUE TO DISLOCATION OF UNKNOWN CAUSE. A 40 MM + 6 135/145* HUMERAL STABILITY CUP WAS EXPLANTED. THIS ITEM WAS REPLACED WITH 40 MM + 9 135/145* HUMERAL STABILITY CUP.

    Patient problems: Joint Dislocation

    MAUDE report 23380650 ↗
  • InjuryMar 27, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION OCCURRED APPROXIMATELY 2 MONTHS AFTER THE PRIMARY SURGERY WHICH OCCURRED ON (B)(6) 2022. NO FALL OR OTHER TRAUMA REPORTED. REVISION OCCURRED DUE TO DISLOCATION OF UNKNOWN CAUSE. 40 MM + 6 STABILITY HUMERAL CUP EXPLANTED AND REPLACED WITH 40 MM + 9 HUMERAL STABILITY CUP WITH 9 MM SPACER.

    Patient problems: Joint Dislocation

    MAUDE report 18987027 ↗
  • InjuryFeb 16, 2024Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION OCCURRED APPROXIMATELY 6 WEEKS AFTER THE PRIOR REVISION SURGERY WHICH OCCURRED ON (B)(6) 2023. THIS WAS PRECEDED BY THE PRIMARY SURGERY ON (B)(6) 2023. NO FALL OR OTHER TRAUMA REPORTED. REVISION OCCURRED FOR DISLOCATION OF UNKNOWN CAUSE. REVISION WAS A TOTAL EXPLANT OF AN FX SYSTEM WITH REPLACEMENT BY A COMPETITOR SYSTEM. EXPLANT INCLUDES: 40 MM + 6 STABILITY HUMERAL CUP, 40 MM CENTERED GLENOSPHERE, 9 MM SPACER, 24 MM CEMENTLESS BASEPLATE, 36/16 SYSTEM STEM, 20 MM CENTRAL SCREW, 30 MM STANDARD SCREW, 20 MM LOCKING SCREW (2), AND 30 MM LOCKING SCREW.

    Patient problems: Joint Dislocation

    MAUDE report 18721748 ↗