LATERALIZED AND AUGMENTED BASEPLATE 105-0026Recalls & reported problems

Fx Solutions · TA6V CEMENTLESS GLENOID BASEPLATE W/ PEG Ti/HA Ø24mm, +6mm LATERALIZED · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
3
Deaths reported
0
Injuries reported
3
Recalls naming it
0

Summary

The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 03701037316795), received between May 23, 2025 and Jul 10, 2026 — classified as 3 injuries.

The most frequently reported specific device problem is “Migration” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 1 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem2
  • Migration1

Patient problems

  • Joint Dislocation2
  • Inadequate Osseointegration1

Recent adverse event reports

The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 10, 2026Adverse Event Without Identified Device or Use Problem

    REVISION OCCURRED ON (B)(6) 2026 APPROXIMATELY 392 DAYS AFTER THE PRIMARY WHICH OCCURRED ON (B)(6) 2025. NO FALL OR OTHER TRAUMA WAS REPORTED. BASED ON COMPARING USAGE FORMS ONLY HUMELOCK REVERSED TA6V CEMENTLESS GLENOID BASEPLATE W/PEG TI/HA Ø24MM, +6MM LATERALIZED, HUMELOCK REVERSED CENTERED GLENOSPHERE W/ SCREW COCR/TA6V 10° TILT Ø36MM, HUMERAL CUP STANDARD PE/TA6V Ø36/+3, TWO STANDARD SCREW TA6V Ø4.5MM L.30MM AND TWO STANDARD SCREW TA6V Ø4.5MM L.25MM WAS EXPLANTED DUE TO DISLOCATION AND REPLACED WITH OFFSET TAPER ADAPTER TA6V Ø24 / Ø10 AND CENTERED HEAD 50X21. FX V135® HUMELOCK STEM TA6V Ø32/08 L. 120MM CEMENTLESS TI/H WAS NOT REPLACED.

    Patient problems: Joint Dislocation

    MAUDE report 25781576 ↗
  • InjuryJun 26, 2025Migration; Migration

    REVISION OCCURRED APPROXIMATELY 21 MONTHS AFTER THE PRIOR REVISION SURGERY, WHICH OCCURRED ON (B)(6) 2023. THE PRIMARY SURGERY OCCURRED ON (B)(6) 2023. NO FALL OR OTHER TRAUMA REPORTED. REVISION OCCURRED DUE TO LOOSENING OF THE BASEPLATE COMPONENT. A 24 MM + 6 LATERALIZED BASEPLATE, 6 MM POST EXTENSION, 40 MM ECCENTRIC GLENOSPHERE, 40 MM +3 HUMERAL STABILITY CUP, 2 OF 9 MM SPACER, AND 3 STANDARD SCREWS WERE EXPLANTED. THESE ITEMS WERE REPLACED WITH A COMPETITOR ANTIBIOTIC SPACER; FX COMPONENTS WERE LISTED ON THE USAGE FORM FOR THE CASE BUT WERE ALL WASTED.

    Patient problems: Inadequate Osseointegration

    MAUDE report 22341553 ↗
  • InjuryMay 23, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION OCCURRED APPROXIMATELY 15 WEEKS AFTER THE PRIOR REVISION SURGERY WHICH OCCURRED ON (B)(6) 2025. THE PRIMARY SURGERY OCCURRED ON (B)(6) 2022. NO FALL OR OTHER TRAUMA REPORTED. REVISION OCCURRED DUE TO DISLOCATION OF UNKNOWN CAUSE. 24 MM + 6 LATERALIZED BASEPLATE, 36 MM CENTERED GLENOSPHERE, 36 MM + 9 HUMERAL STABILITY CUP, AND 4 STANDARD SCREWS EXPLANTED. THESE PARTS WERE REPLACED WITH AN IDENTICAL BASEPLATE, A 6 MM POST EXTENSION, 40 MM CENTERED GLENOSPHERE, 40 MM + 9 135/145 STANDARD HUMERAL CUP, 9 MM SPACER, AND 4 STANDARD SCREWS.

    Patient problems: Joint Dislocation

    MAUDE report 22078356 ↗