MAYFIELD HEAD HOLDER ADAPTOR ROSA3-177DRecalls & reported problems
Medtech · MAYFIELD HEAD HOLDER ADAPTOR instrument Rosa 3.0 Mayfiled head holder mechanical adaptor to connect the support arm to a mayfiled head holder · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 03760244031235), received between Jul 2, 2019 and Jul 2, 2019 — classified as 1 malfunction.
The most frequently reported specific device problem is “Break” (1 report).
7 other recalls cover devices cleared under the same FDA submission (K151359); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Break1
- Mechanical Jam1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 2, 2019Break; Mechanical Jam; Break; Mechanical Jam
PRIOR TO ANY INCISIONS, THE LOCAL FIELD SERVICE ENGINEER, WENT TO LOOSEN THE MAYFIELD HEAD HOLDER ADAPTOR IN ORDER TO PREPARE IT FOR FIXATION TO THE LEKSELL HEAD HOLDER. WHEN ATTEMPTING TO LOOSEN, THE GEAR PORTION OF THE HEAD HOLDER ADAPTOR WOULD NOT DISENGAGE. AFTER ATTEMPTING MANY TIMES, THE THREADED COMPONENT THAT HOLDS THE RATCHETING ARM IN PLACE ENDED UP SNAPPING INTO TWO PIECES. THIS DID NOT DELAY SURGERY. THERE WAS LESS THAN A 5 MINUTES DELAY.
Patient problems: No Clinical Signs, Symptoms or Conditions; No Consequences Or Impact To Patient
MAUDE report 8753317 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K151359. One submission often covers many models, so check the product and lot details in each record.
- Z-1150-2020 · Jan 6, 2020 · TerminatedROSA Brain 3.0 Application-Brain
- Z-1151-2020 · Jan 6, 2020 · TerminatedROSA One 3.1 Brain Application
- Z-0172-2020 · Sep 10, 2019 · TerminatedRosa Brain 3.0, Model No. ROSA 3.0. The device is delivered assembled in a wooden case and protected with plastic bubble and plastic film. Seals are put on the crate. The product i
- Z-1754-2017 · Feb 27, 2017 · TerminatedMEDTECH ROSA Brain 3.0 The device is intended for the spatial positioning and orientation of instrument holders or tool guides to be used by neurosurgeons to guide standard neurosu
- Z-2868-2017 · Oct 11, 2016 · TerminatedROSA Brain, 3.0.0 The device is intended for the spatial positioning and orientation of instrument holders or tool guides to be used by neurosurgeons to guide standard neurosurgica
- Z-0116-2018 · Jul 29, 2016 · TerminatedROSA BRAIN 3.0.0
- Z-0167-2018 · Jul 20, 2016 · TerminatedROSA Brain 3.0.0 Usage: The device is intended for the spatial positioning and orientation of instrument holders or tool guides to be used by neurosurgeons to guide standard neuro
Other Neurological Stereotaxic Instrument devices
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument4 deaths4,668 reports
- Stealthstation® S7™ 9733856Medtronic Navigation, Inc. · Neurological stereotaxic Instrument6 deaths3,908 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death1,896 reports
- StealthStation S8 9735669Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1,831 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument2 deaths1,542 reports
- Fusion™ ENT Image Guidance System 9733560XOMMedtronic Navigation, Inc. · Neurological stereotaxic Instrument1,316 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument8 deaths984 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death695 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page