SpineJack 0909200058Recalls & reported problems

Stryker Corporation · EXPANSION KIT 5.8MM · Class 2 · Implant

Adverse event reports
7
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 03760253800495), received between Jul 26, 2022 and Jul 29, 2025 — classified as 1 injury, 6 malfunctions.

The most frequently reported specific device problem is “Activation Failure” (4 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 1 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 2 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Activation Failure4
  • Separation Failure2
  • Fracture1
  • Migration1
  • Patient Device Interaction Problem1
  • Positioning Problem1
  • Use of Device Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions7

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 29, 2025Activation Failure; Activation Failure

    THIS REPORT SUMMARIZES 1 EVENT FOR THE FAILURE: ACTIVATION FAILURE. - 1 EVENT HAD NO HEALTH CONSEQUENCES OR IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22646533 ↗
  • MalfunctionApr 21, 2025Separation Failure; Activation Failure; Separation Failure; Activation Failure

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT IN WHICH THE DEVICE REPORTEDLY FAILED TO ACTIVATE AND SEPARATE. - 1 EVENT HAD PATIENT INVOLVEMENT; NO PATIENT IMPACT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21876247 ↗
  • InjuryApr 7, 2025Use of Device Problem; Activation Failure; Migration; Use of Device Problem; Activation Failure; Migration

    NO NEW INFORMATION.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 21786551 ↗
  • MalfunctionOct 18, 2024Separation Failure; Activation Failure; Separation Failure; Activation Failure

    IT WAS REPORTED THAT DURING A BIPEDICULAR IMPLANT PROCEDURE AT T12, ONE OF THE SPINEJACK IMPLANTS EXPERIENCED A LOT OF PRESSURE DUE TO HARD BONE AND WOULD NOT EXPAND. ADDITIONALLY, THE SAME IMPLANT WOULD NOT RELEASE FROM THE RELEASE PIN. THE PROCEDURE WAS COMPLETED SUCCESSFULLY AS A UNIPEDICULAR CASE WITH ONLY CEMENT INJECTED ON ONE SIDE. NO DELAY, MEDICAL INTERVENTION, OR ADVERSE CONSEQUENCES WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20480511 ↗
  • MalfunctionJun 19, 2024Patient Device Interaction Problem; Patient Device Interaction Problem

    DURING A 2-LEVEL BIPEDICULAR PROCEDURE AT T11 AND T12 IN A PATIENT WITH SOFT BONE AND CANCER, THE OPERATOR NOTED A CHANGE IN THE INFERIOR ENDPLATE OF THE T10 LEVEL AFTER EXPANSION OF THE SPINEJACK IMPLANTS. THE CHANGE WAS DESCRIBED AS "PUSHED IN A LITTLE." THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY SIGNIFICANT DELAY. NO MEDICAL INTERVENTION OR ADVERSE CONSEQUENCES WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19569755 ↗
  • MalfunctionMay 24, 2023Positioning Problem; Positioning Problem

    IT WAS REPORTED THAT DURING A BIPEDICULAR IMPLANT PROCEDURE THE EXPANSION ASSEMBLY ON ONE SIDE SEEMED TO ADVANCE FURTHER THAN EXPECTED WITHIN THE ACCESS CANNULA, PRESENTING THE POTENTIAL FOR THE IMPLANT TO ALSO REACH AN EXCESSIVE DEPTH WITHIN THE VERTEBRAL BODY. THERE WAS NO REPORT OF THE IMPLANT ACTUALLY REACHING AN EXCESSIVE DEPTH. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT A CLINICALLY-SIGNIFICANT DELAY AND NO MEDICAL INTERVENTION OR ADVERSE CONSEQUENCES WERE REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16993811 ↗
  • MalfunctionJul 26, 2022Fracture; Fracture

    THIS REPORT SUMMARIZES 1 MALFUNCTION EVENT IN WHICH THE DEVICE OR CUTTING ACCESSORY FRACTURED. - 1 EVENT HAD INSUFFICIENT INFORMATION RECEIVED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15107756 ↗

Other Cement, Bone, Vertebroplasty devices

All Cement, Bone, Vertebroplasty devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.