LinkSymphoKnee 880-213/12Recalls & reported problems
WALDEMAR LINK GmbH & Co. KG · Articulating Surfaces, PS · Class 2 · Implant
All models of LinkSymphoKnee (117)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04026575252961), received between Jun 1, 2023 and Jan 19, 2024 — classified as 1 injury, 2 malfunctions.
The most frequently reported specific device problem is “Positioning Failure” (3 reports).
11 other recalls cover devices cleared under the same FDA submission (K202924); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Reports received per month
Most reported problems
Device problems
- Positioning Failure3
- Adverse Event Without Identified Device or Use Problem1
- Difficult or Delayed Positioning1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Failure of Implant1
- Rupture1
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
InjuryJan 19, 2024Difficult or Delayed Positioning; Positioning Failure; Adverse Event Without Identified Device or Use Problem; Difficult or Delayed Positioning; Positioning Failure; Adverse Event Without Identified Device or Use Problem
DURING THE SURGERY, AFTER IMPLANTING THE TIBIAL COMPONENT, THE SURGEON TRIED TO INSERT THE POLY COMPONENT WHICH STRUGGLED TO ENTER, AND ABOVE ALL, DID NOT FIX WITH THE CLASSIC SNAP. THINKING THAT THE PE WAS FAULTY, HE OPENED A SECOND IDENTICAL ONE, BUT THE PROBLEM REPEATED ITSELF. NOT KNOWING WHAT TO DO, NOBODY OF US WAS IN THE OPERATING ROOM, A THIRD COMPONENT OF A HIGHER THICKNESS AS OPENED BUT AGAIN HE HAD DIFFICULTY INSERTING THE COMPONENT AND DIDN'T HEAR THE USUAL CLACKING. AT THIS POINT, HOPING THAT THE INSERT WAS FIXED AND STABLE, BUT WITH SOME CONCERN, THE SURGERY WAS FINISHED. [CUSTOMER]
Patient problems: Failure of Implant; No Clinical Signs, Symptoms or Conditions; Rupture
MAUDE report 18542324 ↗MalfunctionJun 1, 2023Positioning Failure; Positioning Failure
AS CONFIRMED TO LB COMPLAINTS ON (B)(6) 2022 PER K. N., THIS "POLY SEEMED TO NOT ENGAGE". IT WAS CONSIDERED WASTED. THE SURGERY TIME WAS NOT EXTENDED. THIS COMPLAINT SAMPLE WAS RETURNED DIRECTLY TO MANUFACTURER, WHO NOTIFIED LB ON (B)(6) 2022 UPON NOTICE OF ADDITIONAL COMPLAINTS FROM THE SAME DOCTOR, AS NOTED IN PREVIOUSLY INITIATED COMPLAINT (B)(4).. [CUSTOMER].
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17040251 ↗MalfunctionJun 1, 2023Positioning Failure; Positioning Failure
POSITIONING FAILURE OF ARTICULATING SURFACE IN THE TIBIAL COMPONENT. A DIFFERENT ARTICULATING SURFACE WAS USED INSTEAD WITHOUT ANY ISSUE. [CUSTOMER].
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17040148 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K202924. One submission often covers many models, so check the product and lot details in each record.
- Z-2541-2025 · Jul 31, 2025 · Open, ClassifiedLinkSymphoKnee System, Tibial Component, Modular, Symmetric, Sz. 5, CoCrMo/TiNbN, cemented, Fixed. REF Number: 880-100/50
- Z-1701-2025 · Apr 3, 2025 · Open, ClassifiedL-Shaped Femoral Augment; Item Numbers: (1) 880-320/12 (Sz. 0 - cemented sm), (2) 880-320/22 (Sz. 0 - cemented lg), (3) 880-321/12 (Sz. 1-2 - cemented sm), (4) 880-321/22 (Sz. 1-2
- Z-1699-2025 · Apr 3, 2025 · Open, ClassifiedDistal Femoral Augment; Item Numbers: (1) 880-300/11 (Sz. 0 - cemented sm), (2) 880-300/21 (Sz. 0 - cemented lg), (3) 880-301/11 (Sz. 1-2 - cemented sm), (4) 880-301/21 (Sz. 1-2 -
- Z-1700-2025 · Apr 3, 2025 · Open, ClassifiedPosterior Femoral Augment; Item Numbers: (1) 880-310/11 (Sz. 0 - cemented sm), (2) 880-310/21 (Sz. 0 - cemented lg), (3) 880-311/11 (Sz. 1-2 - cemented sm), (4) 880-311/21 (Sz. 1-2
- Z-1702-2025 · Apr 3, 2025 · Open, ClassifiedTibial Augment; Item Numbers: (1) 880-331/11 (Sz. 1-2 - cemented x-sm), (2) 880-331/12 (Sz. 1-2 - cemented sm), (3) 880-331/13 (Sz. 1-2 - cemented md), (4) 880-331/21 (Sz. 1-2 - ce
- Z-1373-2025 · Feb 14, 2025 · Open, ClassifiedModular Stem cylindrical, Tilastan, press-fit cementless, L= 80 mm, DIA = 12 mm, Product Code: 880-601/12
- Z-1374-2025 · Feb 14, 2025 · Open, ClassifiedModular Stem cylindrical, Tilastan, press-fit cementless, L= 80 mm, DIA = 13 mm, Product Code: 880-601/13
- Z-1372-2025 · Feb 14, 2025 · Open, ClassifiedModular Stem cylindrical, Tilastan, press-fit cementless, L= 80 mm, DIA = 11 mm, Product Code: 880-601/11
- Z-1674-2023 · Apr 25, 2023 · Open, ClassifiedLINK SymphoKnee System L-Shaped Femoral Augment, Medial-Right/Lateral-Left, Sz 5-6 Tilastan, cemented. Intended for primary and revision total knee replacement. Item Number: 880-32
- Z-2067-2023 · Dec 23, 2022 · Open, ClassifiedLinkSymphoKnee Distal Femoral Augment - Tilastan - Size. 7-8, Lateral-Right/Medial-Left, 5mm-Intended for primary and revision total knee replacement in skeletally mature patients.
- Z-2066-2023 · Dec 23, 2022 · Open, ClassifiedLinkSymphoKnee Distal Femoral Augment - Tilastan - Size 7-8, Medial-Right/Lateral Left, 5mm- Intended for primary and revision total knee replacement in skeletally mature patients.
Other PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER devices
- ELEOS™ 25001208EOnkos Surgical, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER3 deaths193 reports
- ELEOS™ THSMWRS01MOnkos Surgical, Inc. · PROSTHESIS, KNEE, FEMOROTIBIAL, CONSTRAINED, CEMENTED, METAL/POLYMER190 reports
- "UNITED" USTAR II Hip System 1115-1413United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls3 reports
- "UNITED" USTAR II Hip System 1115-1217United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- "UNITED" USTAR II Hip System 1115-1417United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- "UNITED" USTAR II Hip System 1115-1213United Orthopedic Corp. · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer3 recalls0 reports
- Endo-Model Modular Knee Prosthesis System 15-3816/11WALDEMAR LINK GmbH & Co. KG · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer2 recalls6 reports
- Endo-Model Modular Knee Prosthesis System 15-3816/12WALDEMAR LINK GmbH & Co. KG · Prosthesis, Knee, Femorotibial, Constrained, Cemented, Metal/Polymer2 recalls6 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page