Intica Neo 5 DR-T DF-1 ProMRI 429568Recalls & reported problems
BIOTRONIK SE & Co. KG · Class 3 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04035479156947), received between Oct 29, 2020 and May 28, 2021 — classified as 1 injury, 4 malfunctions.
The most frequently reported specific device problem is “Battery Problem” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Battery Problem2
- Adverse Event Without Identified Device or Use Problem1
- Failure to Capture1
- Failure to Interrogate1
- Inappropriate/Inadequate Shock/Stimulation1
- Premature Elective Replacement Indicator1
Patient problems
- No Clinical Signs, Symptoms or Conditions3
- Asystole1
- Ventricular Fibrillation1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionMay 28, 2021Battery Problem; Battery Problem
IT WAS REPORTED THAT THIS DEVICE WAS PROPHYLACTICALLY EXCHANGED APPROX. 10 MONTHS AFTER THE IMPLANTATION. PLEASE NOTE THIS ICD IS AFFECTED BY A FIELD SAFETY CORRECTIVE ACTION, BIO-LQC, INITIATED IN MARCH 2021
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11904975 ↗MalfunctionMay 13, 2021Battery Problem; Battery Problem
IT WAS REPORTED THAT THE RV LEAD (LINOX SMART SD) WAS CAPPED DUE TO LOW SHOCK IMPEDANCE MEASUREMENTS APPROX. 109 MONTHS AFTER THE IMPLANTATION. DURING THE REVISION SURGERY THE ASSOCIATED ICD WAS PROPHYLACTICALLY EXCHANGED AFTER 9 MONTHS OF IMPLANTATION PERIOD. THIS ICD IS AFFECTED BY A FIELD SAFETY CORRECTIVE ACTION, BIO-LQC, INITIATED IN MARCH 2021.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 11819384 ↗MalfunctionDec 12, 2020Failure to Capture; Failure to Interrogate; Inappropriate/Inadequate Shock/Stimulation; Failure to Capture; Failure to Interrogate; Inappropriate/Inadequate Shock/Stimulation
IT WAS REPORTED, THAT APPROXIMATELY 15 DAYS AFTER IMPLANTATION TIME, APPROPRIATE BUT INEFFECTIVE SHOCKS WERE DELIVERED BY THE IMPLANTED ICD AND AN EXTERNAL SHOCK WAS DELIVERED BY THE EMERGENCY DOCTOR. THE DEVICE COULD NO LONGER BE QUERIED AND IS FUNCTIONALLY INEFFECTIVE (NO MORE VENTRICULAR STIMULATION IN THE CASE OF (B)(6)). ON (B)(6) 2020 THE ICD DELIVERED MULTIPLE SHOCKS, BUT THESE WERE NOT EFFECTIVE. THE EMERGENCY DOCTOR FOUND VENTRICULAR FIBRILLATION AND SHOCKED THE PATIENT EXTERNALLY SEVERAL TIMES. THIS ENABLED THE PATIENT TO BE BROUGHT INTO A NORMAL-FREQUENCY HEART RHYTHM. THE PATIENT WAS ADMITTED TO THE (B)(6) HOSPITAL AND GIVEN AN ECMO DUE TO HIS POOR CONDITION. LATER THE PATIENT WAS TRANSFERRED TO ANOTHER HOSPITAL AND REMAINS IN THE INTENSIVE CARE UNIT.
Patient problems: Ventricular Fibrillation
MAUDE report 10996472 ↗MalfunctionDec 12, 2020Premature Elective Replacement Indicator; Premature Elective Replacement Indicator
AFTER AN IMPLANTATION PERIOD OF APPROX. 3 MONTHS, IT WAS OBSERVED THAT THE DEVICE SHOWS THE ERI STATUS.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10996432 ↗InjuryOct 29, 2020Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
AFTER AN IMPLANTATION PERIOD OF APPROX. 10 MONTHS, AN ASYSTOLE WAS OBSERVED.
Patient problems: Asystole
MAUDE report 10758808 ↗
Other DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER devices
- Rivacor 7 DR-T DF4 ProMRI 429534BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER2 deaths286 reports
- Iperia 7 DR-T DF4 ProMRI 392423BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER3 deaths256 reports
- Ilivia 7 DR-T DF4 ProMRI 404623BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER2 deaths233 reports
- Iperia 7 DR-T DF-1 ProMRI 392409BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER93 reports
- Ilesto 7 DR-T DF-1 US 383562BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER79 reports
- Ilivia 7 DR-T DF-1 ProMRI 404622BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER74 reports
- Ilivia Neo 7 DR-T DF-1 ProMRI 429529BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER1 death56 reports
- Itrevia 7 DR-T DF4 392426BIOTRONIK SE & Co. KG · DEFIBRILLATOR, IMPLANTABLE, DUAL-CHAMBER1 death48 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page