DUROGRIP BM036RRecalls & reported problems
Aesculap AG · DE BAKEY DUROGRIP TC Needleholder, straight, 9", (230 mm), with 0.4 mm pitch of serration, suture 4/0 - 6/0, non-sterile, reusable · Class 1
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04038653028108), received between Nov 5, 2020 and Nov 5, 2020 — classified as 1 malfunction.
The most frequently reported specific device problem is “Product Quality Problem” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Product Quality Problem1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 5, 2020Product Quality Problem; Product Quality Problem
IT WAS REPORTED THAT THERE WAS AN ISSUE WITH BM036R - TC DE'BAKEY NDL HOLDER DEL SERR 230MM. ACCORDING COMPLAINT DESCRIPTION IT WAS REPORTED THAT THE INSTRUMENTS ENTERED THE QA PROCESS AT HOSPITAL. ITEM WAS ACCESSED AND THE FAILURE WAS FOUND .VISIBLE GAP IN SOLDER THAT ADHERES THE TC INSERT. THERE WAS NO PATIENT HARM. ADDITIONAL INFORMATION WAS NOT PROVIDED NOR AVAILABLE / WAS NOT AVAILABLE. THE MALFUNCTION IS FILED UNDER (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 10792120 ↗
Other HOLDER, NEEDLE; ORTHOPEDIC devices
- Sklar Instruments 96-2355ASklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
- Sklar® 96-2587Sklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
- Sklar Instruments 96-2358ASklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
- Sklar Instruments 96-2591ASklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
- Sklar Instruments 96-2583ASklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
- Sklar Instruments 96-2581Sklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
- Sklar Instruments 96-2585ASklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
- Sklar Instruments 96-2586Sklar Corporation · HOLDER, NEEDLE; ORTHOPEDIC1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗