Skip to content

AESCULAP FV046TRecalls & reported problems

Christoph Miethke GmbH & Co. KG · SPRUNG RESERVOIR SET W/DISTAL CATHETER · Class 2 · Implant

All models of AESCULAP (18)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
8
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 04041906131395), received between Sep 14, 2020 and Oct 11, 2024 — classified as 8 injuries.

The most frequently reported specific device problem is “Infusion or Flow Problem” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 1 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 2 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520262
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Infusion or Flow Problem5
  • Mechanical Problem2
  • Complete Blockage1
  • Device Damaged Prior to Use1
  • Leak/Splash1
  • Material Split, Cut or Torn1
  • Obstruction of Flow1

Patient problems

  • Hydrocephalus8

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 11, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A PROGAV 2.0 SHUNTSYSTEM (REGARDING MEDWATCH FORM (B)(4)) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2023. THE SPRUNG RESERVOIR SET (FV046T) FROM THIS REPORT WAS SUBSEQUENTLY CONNECTED TO THE ABOVEMENTIONED PROGAV 2.0 SHUNTSYSTEM BY THE HOSPITAL. ACCORDING TO THE COMPLAINANT, THE SHUNT SYSTEM CAUSED AN OVERDRAINAGE AND HAD ADJUSTMENT DIFFICULTIES. THE PATIENT UNDERWENT A REVISION PROCEDURE. THE COMPLAINANT DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. AGE: 37 YEARS. HEIGHT: 150 CM. WEIGHT: 48 KG. GENDER: FEMALE.

    Patient problems: Hydrocephalus

    MAUDE report 20426835 ↗
  • InjurySep 18, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A SPRUNR RESERVOIR (#FV146T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2023. ACCORDING TO THE COMPLAINANT, THE SHUNT SYSTEM SHOWED AN UNDER-DRAINAGE. THE PATIENT UNDERWENT A REVISION PROCEDURE PERFORMED ON (B)(6) 2024. THE COMPLAINANT DEVICE HAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. AGE: 54 YEARS. WEIGHT: 107 KGS. HEIGHT: 179 CM. GENDER: MALE. SAME EVENT AS # REPORTED HEREIN.

    Patient problems: Hydrocephalus

    MAUDE report 20245659 ↗
  • InjurySep 16, 2024Device Damaged Prior to Use; Material Split, Cut or Torn; Device Damaged Prior to Use; Material Split, Cut or Torn

    THE DEVICE (PART OF #(B)(6) - VENTRICULAR CATHETER) WAS RETURNED TO THE MANUFACTURER FOR EXAMINATION.

    Patient problems: Hydrocephalus

    MAUDE report 20225140 ↗
  • InjuryMay 28, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A SPRUNG RESERVOIR-SET (# FV046T) WAS IMPLANTED DURING A REVISION PROCEDURE (MEDWATCH#3 004721439-2024-00120) PERFORMED ON (B)(6) 2024. THE SPRUNG RESERVOIR WAS IMPLANTED TOGETHER WITH # FX418T (MEDWATCH#3004721439-2024-00135). ACCORDING TO THE COMPLAINANT, THE SHUNT SYSTEM CAUSED A BLOCKAGE. THE PATIENT UNDERWENT AN ADDITIONAL REVISION PROCEDURE. THE COMPLAINANT DEVICE WILL BE RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. AGE: 7 MONTHS HEIGHT: 64 CM WEIGHT: 9 KG GENDER: MALE SAME INCIDENT/PATIENT AS MEDWATCH# 3004721439-2024-00135

    Patient problems: Hydrocephalus

    MAUDE report 19405675 ↗
  • InjuryMar 25, 2024Leak/Splash; Leak/Splash

    IT WAS REPORTED THAT A SPRUNG RESERVOIR (#FV046T) WAS IMPLANTED ON (B)(6) 2024. ACCORDING TO THE COMPLAINANT, THE SHUNT SYSTEM HAD A LEAK FROM THE CATHETER ON THE DISTAL SIDE OF THE RESERVOIR. THE RESERVOIR WAS EXPLANTED AGAIN. THE COMPLAINANT'S DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE.

    Patient problems: Hydrocephalus

    MAUDE report 18967886 ↗
  • InjuryJan 27, 2023Mechanical Problem; Infusion or Flow Problem; Mechanical Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A SPRUNG RESERVOIR (PART#: FV046T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2022. ACCORDING TO THE COMPLAINANT, THE RESERVOIR IN COMBINATION WITH A PROGAV 2.0 WAS BELIEVED TO BE OPERATING IN OVERDRAINAGE. THE PATIENT UNDERWENT A REVISION PROCEDURE. THE COMPLAINT DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. AGE: 17 YEARS, HEIGHT: 153 CENTIMETERS (CM), WEIGHT: 57 KILOGRAMS (KG), GENDER: FEMALE. SAME EVENT AS MEDWATCH#: 3004721439-2022-00435 AND 3004721439-2022-00437.

    Patient problems: Hydrocephalus

    MAUDE report 16258259 ↗
  • InjuryApr 9, 2021Mechanical Problem; Infusion or Flow Problem; Mechanical Problem; Infusion or Flow Problem

    IT WAS REPORTED TO MIETHKE THAT A SPRUNG RESERVOIR (PART # FV046T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2021. ACCORDING TO THE COMPLAINANT, THE SPRUNG RESERVOIR MALFUNCTIONED. THE PATIENT UNDERWENT A REVISION PROCEDURE ON (B)(6) 2021. THE COMPLAINT DEVICE WILL BE RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. PATIENT INFORMATIONS: AGE: (B)(6) YEARS; GENDER: FEMALE. SAME PATIENT/EVENT: MEDWATCH#3004721439-2021-00067.

    Patient problems: Hydrocephalus

    MAUDE report 11645019 ↗
  • InjurySep 14, 2020Complete Blockage; Obstruction of Flow; Complete Blockage; Obstruction of Flow

    THE INFORMATION THAT THE PRODUCT IS NOT AVAILABLE FOR INVESTIGATION IS REACHED TO US ON 10/06/2020. ASSOCIATED MEDWATCH # 3004721439-2020-00184.

    Patient problems: Hydrocephalus

    MAUDE report 10532295 ↗

Other Shunt, central nervous system and components devices

All Shunt, central nervous system and components devices →