proGAV® FV433TRecalls & reported problems
Christoph Miethke GmbH & Co. KG · PROGAV SYS W/SA 15 A.CONTROL RESERVOIR · Class 2 · Implant
All models of proGAV (28)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 4
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04041906132453), received between Dec 10, 2020 and Nov 30, 2021 — classified as 4 injuries, 2 malfunctions.
The most frequently reported specific device problem is “Mechanical Problem” (5 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Mechanical Problem5
- Infusion or Flow Problem2
Patient problems
- Hydrocephalus6
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionNov 30, 2021Mechanical Problem; Mechanical Problem
ACCORDING TO THE COMPLAINANT A PROGAV HAD A FAILURE DURING USE. THE PATIENT WAS ORIGINALLY SCHEDULED FOR IMPLANTATION ON (B)(6) 2017; THERE WAS NO CHANGE IN VALUE AND DEVICE WOULD NOT CALIBRATE EVEN AFTER MULTIPLE ATTEMPTS. THE VALVE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. FURTHER DETAILS WERE NOT PROVIDED.
Patient problems: Hydrocephalus
MAUDE report 12892818 ↗MalfunctionNov 30, 2021Mechanical Problem; Mechanical Problem
ACCORDING TO THE COMPLAINANT A PROGAV HAD A FAILURE DURING USE. THE PATIENT WAS ORIGINALLY SCHEDULED FOR IMPLANTATION ON (B)(6) 2017; THE DEVICE WOULD NOT CALIBRATE. THE VALVE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. FURTHER DETAILS WERE NOT PROVIDED.
Patient problems: Hydrocephalus
MAUDE report 12892810 ↗InjuryNov 1, 2021Mechanical Problem; Mechanical Problem
ACCORDING TO THE COMPLAINANT A PROGAV HAD A "DYSFUNCTION" POSTOPERATIVELY. THE PATIENT WAS ORIGINALLY IMPLANTED ON (B)(6) 2016.. THE VALVE WAS EXPLANTED ON (B)(6) 2017 AND RETURNED TO THE MANUFACTURER FOR EVALUATION. FURTHER DETAILS WERE NOT PROVIDED.
Patient problems: Hydrocephalus
MAUDE report 12728851 ↗InjuryOct 19, 2021Infusion or Flow Problem; Infusion or Flow Problem
IT WAS REPORTED THAT THERE WAS AN ISSUE WITH FV433T -PROGAV SYS W/SA 15 A.CONTROL RESERVOIR ACCORDING TO THE COMPLAINANT, THE VALVE WAS BELIEVED TO BE NOT ADJUSTABLE. THE VALVE WAS EXPLANTED AND RETURNED TO THE MANUFACTURER FOR EVALUATION. FURTHER DETAILS WERE NOT PROVIDED.
Patient problems: Hydrocephalus
MAUDE report 12658545 ↗InjurySep 16, 2021Mechanical Problem; Mechanical Problem
ACCORDING TO THE COMPLAINANT A PROGAV WAS SUSPECTED OF POSTOPERATIVE OCCLUSION. THE PATIENT WAS ORIGINALLY IMPLANTED AT AN UNSPECIFIED TIME. THE EVENT DATE WAS NOTED AS (B)(6) 2016. THE VALVE WAS EXPLANTED AND RETURNED TO THE MANUFACTURER FOR EVALUATION. FURTHER DETAILS WERE NOT PROVIDED.
Patient problems: Hydrocephalus
MAUDE report 12480915 ↗InjuryDec 10, 2020Mechanical Problem; Infusion or Flow Problem; Mechanical Problem; Infusion or Flow Problem
IT WAS REPORTED THAT THERE WAS A PROBLEM WITH A PROSA SHUNT SYSTEM. THE SURGEON REPLACED THE SHUNT SYSTEM DUE TO SUSPECTED OVERDRAINAGE AND ADJUSTMENT PROBLEMS. PATIENT INFORMATIONS: AGE: (B)(6) YEARS. HEIGHT: 150 CM. WEIGHT: (B)(6) KG. IMPLANTATION: (B)(6) 2009. REMOVAL: (B)(6) 2020.
Patient problems: Hydrocephalus
MAUDE report 10983135 ↗
Other Shunt, central nervous system and components devices
- NATUS EDS3 DRAINAGE SYSTEM NT821731CNatus Medical Incorporated · Shunt, Central Nervous System And Components1 recall208 reports
- Exacta™ 46700Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall2 deaths163 reports
- Strata® 42866Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 death160 reports
- proGAV 2.0® FX410TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components119 reports
- Becker® 46128Medtronic Ps Medical, Inc. · Shunt, central nervous system and components1 recall50 reports
- PROGAV 2.0 FX643TAesculap AG · Shunt, central nervous system and components100 reports
- proSA® FV701TChristoph Miethke GmbH & Co. KG · Shunt, central nervous system and components82 reports
- M.BLUE PLUS FX804TAesculap AG · Shunt, central nervous system and components82 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page