GAV 2.0 FX214TRecalls & reported problems

Aesculap AG · GAV 2.0 VALVE 10/25 · Class 2 · Implant

All models of GAV 2.0 (16)

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
9
Deaths reported
0
Injuries reported
9
Recalls naming it
0

Summary

The FDA's MAUDE database contains 9 adverse event reports that list this exact device (DI 04041906500047), received between May 24, 2023 and Oct 28, 2024 — classified as 9 injuries.

The most frequently reported specific device problem is “Infusion or Flow Problem” (7 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 3 reportsJul 2024: 2 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 1 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520263
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Infusion or Flow Problem7
  • Excess Flow or Over-Infusion1
  • Insufficient Flow or Under Infusion1

Patient problems

  • Hydrocephalus8
  • Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available1

Recent adverse event reports

The 9 most recent of 9 reports, in the reporter's own words as published by the FDA.

  • InjuryOct 28, 2024Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    IT WAS REPORTED THAT A GAV 2.0 (#FX214T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2024. ACCORDING TO THE COMPLAINANT, THE SHUNT SYSTEM CAUSED AN UNDERDRAINAGE. THE PATIENT UNDERWENT A REVISION PROCEDURE ON (B)(6) 2024. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. THE COMPLAINANT DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION.

    Patient problems: Hydrocephalus

    MAUDE report 20546222 ↗
  • InjuryJul 30, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A GAV 2.0 (#FX214T) WAS IMPLANTED DURING A PROCEDURE ON (B)(6) 2024. ACCORDING TO THE COMPLAINANT, THE VALVE WAS EXPLANTED DUE TO A BLOCKAGE. THE PATIENT UNDERWENT A REVISION PROCEDURE PERFORMED ON (B)(6) 2024. THE COMPLAINANT DEVICE HAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. AGE: 1 YEARS, 2 MONTHS WEIGHT: 5 KGS, HEIGHT: UNKNOWN, GENDER: FEMALE.

    Patient problems: Hydrocephalus

    MAUDE report 19860602 ↗
  • InjuryJul 30, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A GAV 2.0 (#FX211T) WAS IMPLANTED DURING A PROCEDURE. ACCORDING TO THE COMPLAINANT, THE VALVE WAS EXPLANTED DUE TO A BLOCKAGE. THE COMPLAINANT DEVICE WILL BE RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE.

    Patient problems: Hydrocephalus

    MAUDE report 19860601 ↗
  • InjuryJun 10, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A GAV 2.0 (#FX214T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2023. ACCORDING TO THE COMPLAINANT, THE SHUNT SYSTEM HAD A MALFUNTION. NO FURTHER INFORMATION WERE GIVEN VIA THE QUESTIONNAIRE. THE PATIENT UNDERWENT A REVISION PROCEDURE. THE COMPLAINANT DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. NO PATIENT DATA AVAILABLE.

    Patient problems: Hydrocephalus

    MAUDE report 19499592 ↗
  • InjuryJun 10, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A GAV 2.0 (#FX214T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2024. ACCORDING TO THE COMPLAINANT, THE VALVE CAUSED AN UNDERDRAINAGE. THE PATIENT UNDERWENT A REVISION PROCEDURE. THE COMPLAINANT DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. AGE: 4 YEARS WEIGHT: 19 KG GENDER: FEMALE.

    Patient problems: Hydrocephalus

    MAUDE report 19499362 ↗
  • InjuryJun 10, 2024Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A GAV 2.0 (#FX214T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON (B)(6) 2023. ACCORDING TO THE COMPLAINANT, THE SHUNT SYSTEM CAUSED AN UNDERDRAINAGE THE PATIENT UNDERWENT A REVISION PROCEDURE. THE COMPLAINANT DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. AGE: 3 MONTHS HEIGHT: 40 CM WEIGHT: 3 KG GENDER: MALE.

    Patient problems: Hydrocephalus

    MAUDE report 19498495 ↗
  • InjuryOct 17, 2023Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A GAV 2.0 VALVE 10/25 (FX214T) WAS IMPLANTED DURING A PROCEDURE. ACCORDING TO THE COMPLAINANT, THE VALVE WAS BELIEVED TO BE BLOCKED. THE PATIENT UNDERWENT A REVISION PROCEDURE. THE COMPLAINT DEVICE WAS RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. NO PATIENT DATA WERE SUBMITTED.

    Patient problems: Hydrocephalus

    MAUDE report 17949672 ↗
  • InjuryMay 24, 2023Insufficient Flow or Under Infusion; Insufficient Flow or Under Infusion

    IT WAS REPORTED THAT A GAV 2.0 (#FX214T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON AN UNKNOWN DATE. ACCORDING TO THE COMPLAINANT, THE PATIENT WAS BROUGHT BACK FOR OTHER UNSPECIFIED COMPLICATIONS. ADDITIONAL INFORMATION WAS RECEIVED WHICH INDICATED THAT THE COMPLICATIONS WERE UNRELATED TO THE SHUNT TREATMENT. HOWEVER, THE PHYSICIAN BELIEVED ADDITIONAL DRAINAGE WAS NEEDED, AND PLANNED TO SWAP THE DEVICE WITH A PROGRAMMABLE VALVE. DURING THE REVISION SURGERY, WHEN THE SHUNT WAS CHECKED IT DID NOT "MOVE THE MANOMETER WITH DISTAL CATHETER STILL IN PLACE." HOWEVER, THE MANOMETER DRAINED AT A NORMAL RATE AFTER THE VALVE WAS REMOVED WITH JUST THE DISTAL CATHETER IN PLACE (STILL IN THE ABDOMEN).THE DEVICE WAS REPLACED WITH ANOTHER MANUFACTURER'S DEVICE. THE COMPLAINT DEVICE HAS NOT BEEN RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE. THE ADVERSE EVENT IS FILED UNDER AIC REFERENCE (B)(4).

    Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available

    MAUDE report 16995560 ↗
  • InjuryMay 24, 2023Infusion or Flow Problem; Infusion or Flow Problem

    IT WAS REPORTED THAT A GAV 2.0 (#FX214T) WAS IMPLANTED DURING A PROCEDURE PERFORMED ON AN UNKNOWN DATE. ACCORDING TO THE COMPLAINANT, THE PATIENT WAS BROUGHT BACK FOR OTHER UNSPECIFIED COMPLICATIONS. ADDITIONAL INFORMATION WAS RECEIVED WHICH INDICATED THAT THE COMPLICATIONS WERE UNRELATED TO THE SHUNT TREATMENT. HOWEVER, THE PHYSICIAN BELIEVED ADDITIONAL DRAINAGE WAS NEEDED, AND PLANNED TO SWAP THE DEVICE WITH A PROGRAMMABLE VALVE. DURING THE REVISION SURGERY, WHEN THE SHUNT WAS CHECKED IT DID NOT "MOVE THE MANOMETER WITH DISTAL CATHETER STILL IN PLACE." HOWEVER, THE MANOMETER DRAINED AT A NORMAL RATE AFTER THE VALVE WAS REMOVED WITH JUST THE DISTAL CATHETER IN PLACE (STILL IN THE ABDOMEN).THE DEVICE WAS REPLACED WITH ANOTHER MANUFACTURER'S DEVICE. THE COMPLAINT DEVICE HAS NOT BEEN RETURNED TO THE MANUFACTURER FOR EVALUATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE REVISION PROCEDURE.

    Patient problems: Hydrocephalus

    MAUDE report 16992609 ↗

Other Shunt, central nervous system and components devices

All Shunt, central nervous system and components devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page