Screw tension device 10033700Recalls & reported problems
MAQUET GmbH · Class 1
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046768000247), received between Apr 5, 2024 and Apr 5, 2024 — classified as 1 malfunction.
The most frequently reported specific device problem is “Crack” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Reports received per month
Most reported problems
Device problems
- Crack1
- Detachment of Device or Device Component1
- Unintended Movement1
Patient problems
- No Clinical Signs, Symptoms or Conditions1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionApr 5, 2024Crack; Detachment of Device or Device Component; Unintended Movement; Crack; Detachment of Device or Device Component; Unintended Movement
ON 26TH FEBRUARY 2024, GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF OUR ACCESSORIES - (B)(6) - SCREW TENSION DEVICE USED WITH 141901JC - EXTENSION DEVICE. AS IT WAS STATED AND CONFIRMED WITH THE PHOTOGRAPHIC EVIDENCE, CRACKS IN SCREW FIXING PARTS OF THE HOUSING WERE DISCOVERED. ON (B)(6) 2024, ADDITIONAL INFORMATION WAS PROVIDED. IT HAS BEEN CONFIRMED THAT THE ISSUE OCCURRED DURING HIP JOINT DISPLACEMENT SURGERY ON AN ANESTHETIZED PATIENT. AS IT WAS STATED, THE ACCESSORY DETACHED COMPLETELY LEADING TO SLOW CHANGE IN PATIENT POSITION THAT WAS UNDER STAFF CONTROL. THE ISSUE RESULTED IN A DELAY IN PROCEDURE. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE BASED ON THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATIONS, NAMELY THE DETACHMENT OF THE ACCESSORY LEADING TO CHANGE IN THE PATIENT POSITION AND DELAY IN SURGERY RESULTING IN PROLONGED ANESTHESIA TIME, WERE TO REOCCUR.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 19048417 ↗
FDA clearance and classification
The FDA regulates product code BWN (table and attachments, operating-room) under 21 CFR 878.4950 as a Class I device. 21 CFR 878.4950 ↗
Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the Screw tension device 10033700
Has the Screw tension device 10033700 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04046768000247), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the Screw tension device 10033700?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 5, 2024. That report lists device problems “Crack” (1), “Detachment of Device or Device Component” (1) and “Unintended Movement” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the Screw tension device 10033700?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the Screw tension device 10033700 FDA approved?
Devices of this type (product code BWN) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by MAQUET GmbH.
Who makes the Screw tension device 10033700, and is it still sold?
The FDA's device database lists MAQUET GmbH as the company responsible for it (brand Screw tension device, model 10033700). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other TABLE AND ATTACHMENTS, OPERATING-ROOM devices
- Arthrex® AR-1747-BArthrex, Inc. · TABLE AND ATTACHMENTS, OPERATING-ROOM12 reports
- Arthrex® AR-1644Arthrex, Inc. · Table and attachments, operating-room5 reports
- Leg holder 100380A0MAQUET GmbH · TABLE AND ATTACHMENTS, OPERATING-ROOM4 reports
- Arthrex® AR-1560-02Arthrex, Inc. · TABLE AND ATTACHMENTS, OPERATING-ROOM4 reports
- Pair of leg plates 113373BCMAQUET GmbH · TABLE AND ATTACHMENTS, OPERATING-ROOM3 reports
- Arthrex® AR-1500Arthrex, Inc. · TABLE AND ATTACHMENTS, OPERATING-ROOM3 reports
- Arthrex® AR-1560Arthrex, Inc. · TABLE AND ATTACHMENTS, OPERATING-ROOM2 reports
- Seat plate extension 116055DCMAQUET GmbH · TABLE AND ATTACHMENTS, OPERATING-ROOM2 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.