Traction device 141901JCRecalls & reported problems

MAQUET GmbH · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046768080287), received between Apr 22, 2024 and Apr 22, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Difficult to Open or Close” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Difficult to Open or Close1
  • Positioning Failure1
  • Solder Joint Fracture1
  • Unintended Movement1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 22, 2024Positioning Failure; Solder Joint Fracture; Difficult to Open or Close; Unintended Movement; Positioning Failure; Solder Joint Fracture; Difficult to Open or Close; Unintended Movement

    GETINGE BECAME AWARE OF AN ISSUE WITH ONE OF OUR DEVICES. LATER ON, ADDITIONAL INFORMATION WAS RECEIVED AND IT WAS CONFIRMED THAT THE INCIDENT WITH THE PATIENT OCCURRED ON THE 141901JC EXTENSION DEVICE. AFTERWARD, FURTHER DETAILS WERE PROVIDED. AS IT WAS STATED, THE 31138834 TENSION BLOCK SHORT WELDING GROUP WAS BROKEN AND LOCKING/UNLOCKING WAS NOT POSSIBLE. CONSEQUENTLY, THE TRACTION DEVICE HAD TO BE REPLACED. AS A RESULT, THE PROCEDURE WAS DELAYED. THE ISSUE OCCURRED DURING FEMUR FRACTURE SURGERY ON THE ANESTHETIZED PATIENT. THERE WAS NO INJURY REPORTED, HOWEVER, WE DECIDED TO REPORT THE ISSUE BASED ON THE POTENTIAL FOR SERIOUS INJURY IF THE SITUATION, NAMELY UNINTENDED MOTION OF THE DEVICE OCCURRING WITH THE PATIENT ON THE TABLE, WAS TO REOCCUR.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19151989 ↗

FDA clearance and classification

The FDA regulates product code BWN (table and attachments, operating-room) under 21 CFR 878.4950 as a Class I device. 21 CFR 878.4950 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the Traction device 141901JC

Has the Traction device 141901JC been recalled?

No FDA recall record in our data names this exact device identifier (DI 04046768080287), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the Traction device 141901JC?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Apr 22, 2024. That report lists device problems “Difficult to Open or Close” (1), “Positioning Failure” (1) and “Solder Joint Fracture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the Traction device 141901JC?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the Traction device 141901JC FDA approved?

Devices of this type (product code BWN) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by MAQUET GmbH.

Who makes the Traction device 141901JC, and is it still sold?

The FDA's device database lists MAQUET GmbH as the company responsible for it (brand Traction device, model 141901JC). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other TABLE AND ATTACHMENTS, OPERATING-ROOM devices

All TABLE AND ATTACHMENTS, OPERATING-ROOM devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page