Introcan Safety ® 2 4242004-02Recalls & reported problems

B. Braun Medical Inc. · Introcan Safety® 2 IV Catheter - 22 Ga. x 1.0 in. · Class 2

All models of Introcan Safety 2 (9)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
15
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 15 adverse event reports that list this exact device (DI 04046955745869), received between Sep 8, 2025 and Mar 26, 2026 — classified as 15 malfunctions.

The most frequently reported specific device problem is “Fail-Safe Problem” (8 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 4 reportsOct 2025: 2 reportsNov 2025: 2 reportsDec 2025: 5 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 1 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520265
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Fail-Safe Problem8
  • Contamination /Decontamination Problem4
  • Detachment of Device or Device Component3
  • Break2
  • Difficult to Remove1
  • Leak/Splash1
  • Material Deformation1

Patient problems

  • No Clinical Signs, Symptoms or Conditions13
  • Needle Stick/Puncture2
  • Exposure to Body Fluids1

Recent adverse event reports

The 15 most recent of 15 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 26, 2026Fail-Safe Problem

    AS REPORTED BY THE USER FACILITY: REASON OF COMPLAINT: EMAIL RECEIVED: "WE RECEIVED A REPORT THAT ON (B)(6) 2026, AN RN ON THE FOURTH FLOOR AT TRADITION HOSPITAL COMPLETED IV INSERTION WITH CATALOG 4242004-02, LOT#25M02G8B05. THE SAFETY HAD MALFUNCTIONED AND WAS NOT FULLY ENGAGED/NOT COVERING NEEDLE RESULTING IN A NEEDLE STICK INJURY WHILE CLEANING UP THEIR WORKSPACE. TO MY KNOWLEDGE, THE SAMPLE WAS NOT SAVED." NEEDLESTICK INJURY WITH IS2. PATIENT INJURY NO.

    Patient problems: Needle Stick/Puncture

    MAUDE report 24697914 ↗
  • MalfunctionFeb 4, 2026Break

    ACCORDING TO THE COMPLAINANT, PRIOR TO USE, AN ISSUE WITH THE INTROCAN SAFETY 2 IV CATHETER WAS IDENTIFIED. AN IMAGE WAS SUPPLIED BY THE REPORTER WHICH REVEALED THAT THE NEEDLE AND CATHETER WERE BROKEN. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 24257061 ↗
  • MalfunctionDec 23, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem

    AS REPORTED BY THE USER FACILITY: ISSUE: BROWN LIQUID IN THE CENTER OF THE CATHETER HUB.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23881540 ↗
  • MalfunctionDec 19, 2025Detachment of Device or Device Component; Fail-Safe Problem; Detachment of Device or Device Component; Fail-Safe Problem

    AS REPORTED BY THE USER FACILITY: REASON OF COMPLAINT: INTROCAN SAFETY 2, 22G SAFETY FAILED WHEN NEEDLE WAS RETRACTED THROUGH THE HUB RESULTING IN AN EXPOSED NEEDLE TIP. THE INNER WRKINGS OF THE HUB WERE ALSO REMOVED AND APPEAR TO HAVE BEEN CAUGHT ON THE SAFETY CLIP. IMAGE AND EMAIL FROM THE CUSTOMER ATTACHED. THE DEVICE WAS NOT RETAINED AND THE LOT NUMBER WAS NOT RECORDED. PATIENT INJURY: NO.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23851203 ↗
  • MalfunctionDec 4, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem

    CALL TO CUSTOMER MADE BY THE COMPLAINT ADVOCATE CONFIRMED THAT THE UNANNOUNCED SAMPLES WAS ANOTHER DEVICE NOTED TO HAVE A SMALL AREA OF YELLOW AT THE TIP IN FRONT OF THE VALVE. SPOKE TO REPORTER (B)(6). CALL MADE AT 2:11 ON (B)(6) 2025.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23719993 ↗
  • MalfunctionDec 3, 2025Difficult to Remove; Fail-Safe Problem; Material Deformation; Difficult to Remove; Fail-Safe Problem; Material Deformation

    AS REPORTED BY THE USER FACILITY: SAFETY MECHANISM CAUGHT ON CATHETER. PATIENT INJURY: NO.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23706905 ↗
  • MalfunctionDec 3, 2025Fail-Safe Problem; Fail-Safe Problem

    ACCORDING TO THE COMPLAINANT, THE SAFETY MECHANISM WAS CAUGHT ON THE CATHETER. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23704366 ↗
  • MalfunctionNov 11, 2025Detachment of Device or Device Component; Fail-Safe Problem; Detachment of Device or Device Component; Fail-Safe Problem

    ACCORDING TO THE COMPLAINANT THE SAFETY SHIELD APPEARS TO BE STUCK IN THE BLOOD CONTROL SEPTUM, THEY BOTH CAME OUT OF THE HUB, AND THE SAFETY DID NOT ENGAGE LEAVING THE NEEDLE TIP EXPOSED. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23523617 ↗
  • MalfunctionNov 7, 2025Fail-Safe Problem; Fail-Safe Problem

    AS REPORTED BY THE USER FACILITY: REASON OF COMPLAINT: WHEN THE CLINICIAN REMOVED THE NEEDLE, THE SAFETY CLIP DID NOT ENGAGE AS THE BLOOD CONTROL VALVE CAME OUT WITH NEEDLE AND BLOCKED THE SAFETY CLIP FROM ENGAGING.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23496800 ↗
  • MalfunctionOct 23, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem

    ACCORDING TO THE COMPLAINANT, PRIOR TO USE, A 22 GAUGE (G) IV CATHETER WAS OBSERVED TO HAVE A YELLOW DISCOLORATION INSIDE THE BLUE HUB NEAR THE TIP IN FRONT OF THE VALVE. UPON INSPECTION OF THE INVENTORY, TWO ADDITIONAL 22G IV CATHETERS FROM THE SAME LOT WERE FOUND TO HAVE SIMILAR YELLOW DISCOLORATION IN THE SAME LOCATION. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THE EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23372488 ↗
  • MalfunctionOct 22, 2025Fail-Safe Problem; Fail-Safe Problem

    AS REPORTED BY THE USER FACILITY: REASON OF COMPLAINT: 22G INTROCAN SAFETY2 WHEN SYTLET REMOVED, BLOOD CONTROL SEPTUM WAS ATTACHED TO THE STYLET AND SAFETY MECHANISM DID NOT ENGAGE. PATIENT INJURY NO.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23357812 ↗
  • MalfunctionSep 19, 2025Break; Break

    AS REPORTED BY THE USER FACILITY: BRIEF INQUIRY DESCRIPTION HOLE IN IVC AND SHEARING THE SHEATH DETAILED INQUIRY DESCRIPTION THERE APPEARS TO BE A HOLE IN THE CATHLONS NEXT TO THE PLASTIC HUB ALSO SEVERAL OF THESE ARE SHEARING THE SHEATH ON INSERTION.

    Patient problems: Needle Stick/Puncture; No Clinical Signs, Symptoms or Conditions

    MAUDE report 23100447 ↗
  • MalfunctionSep 19, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem

    AS REPORTED BY THE USER FACILITY: DETAILED INQUIRY DESCRIPTION THE NURSES FOUND SMALL PIECES OF PLASTIC ON THE OUTSIDE OF THE CATHETER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23096126 ↗
  • MalfunctionSep 9, 2025Leak/Splash; Leak/Splash

    ACCORDING TO THE COMPLAINANT, A CATHETER LEAKAGE OCCURRED. REPORTEDLY, THE INCIDENT RESULTED IN BLOOD BEING SPLASHED INTO AN EMPLOYEE'S FACE RESULTING IN BLOODBORNE PATHOGEN EXPOSURE. ALTHOUGH REQUESTED, NO ADDITIONAL INFORMATION HAS BEEN MADE AVAILABLE. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: Exposure to Body Fluids

    MAUDE report 23004242 ↗
  • MalfunctionSep 8, 2025Detachment of Device or Device Component; Fail-Safe Problem; Detachment of Device or Device Component; Fail-Safe Problem

    ACCORDING TO THE EVENT DESCRIPTION DURING THE DEMONSTRATION OF THE PRODUCT THE SEPTUM CAME OUT WITH NEEDLE/SAFETY SHIELD. THE SAFETY SHIELD DIDN'T CLAMP OVER TIP OF NEEDLE.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22991954 ↗

Other Catheter, intravascular, therapeutic, short-term less than 30 days devices

All Catheter, intravascular, therapeutic, short-term less than 30 days devices →