AS VEGA System® PS NX018ZRecalls & reported problems
Aesculap AG · AS VEGA PS FEMORAL COMP.CEMENTED F8L · Class 2 · Implant
All models of AS VEGA System PS (28)
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046963810009), received between Sep 8, 2025 and Sep 8, 2025 — classified as 1 injury.
The most frequently reported specific device problem is “Patient-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Patient-Device Incompatibility1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjurySep 8, 2025Patient-Device Incompatibility; Patient-Device Incompatibility
THE PATIENT PRESENTED WITH PAIN AND SWELLING OF THE LEFT KNEE. IMAGING DEMONSTRATED LOOSENING OF THE VEGA KNEE SYSTEM. ON (B)(6) 2025, THE PATIENT UNDERWENT REVISION TOTAL KNEE ARTHROPLASTY OF THE LEFT KNEE FOR LOOSENING OF PRIOR COMPONENTS. PREOPERATIVE EVALUATION INDICATED ASEPTIC LOOSENING; NO INFECTION WAS DETECTED. INTRAOPERATIVELY, THE TIBIAL COMPONENT WAS NOTED TO BE GROSSLY LOOSE WITH NO CEMENT PRESENT ON ANY ASPECT OF THE IMPLANT. THE FEMORAL COMPONENT WAS ALSO LOOSE AND REMOVED EASILY WITH LIGHT TAPPING. THE PATELLAR COMPONENT WAS STABLE WITH NO EVIDENCE OF LOOSENING. FINDINGS WERE CONSISTENT WITH IMPLANT DEBONDING AT THE CEMENT INTERFACE. THE FEMUR AND TIBIA WERE PREPARED, AND REVISION FEMORAL AND TIBIAL COMPONENTS WERE IMPLANTED USING CEMENT FIXATION. A POLYETHYLENE INSERT AND MODULAR AUGMENTATION COMPONENTS WERE PLACED FOR STABILITY. AN ALLOGRAFT AND BONE CEMENT WERE ALSO UTILIZED. FINAL INSPECTION CONFIRMED STABLE FIXATION AND APPROPRIATE ALIGNMENT. THE WOUND WAS IRRIGATED, VANCOMYCIN POWDER WAS APPLIED, AND THE CAPSULE WAS CLOSED. THE PATIENT TOLERATED THE PROCEDURE AND WAS TRANSFERRED TO PACU IN STABLE CONDITION.
Patient problems: Failure of Implant
MAUDE report 22994164 ↗
Other PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER devices
- ATTUNE 1506-00-005Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER589 reports
- ATTUNE 1506-00-004Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER580 reports
- JOURNEY 74012812Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER502 reports
- JOURNEY 74011856Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER438 reports
- PERSONA™ 42-5099-094-00Zimmer, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER406 reports
- JOURNEY 74011857Smith & Nephew, Inc. · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER388 reports
- ATTUNE 1506-00-007Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER288 reports
- ATTUNE 1506-00-003Depuy (Ireland) · PROSTHESIS, KNEE, PATELLOFEMOROTIBIAL, SEMI-CONSTRAINED, CEMENTED, POLYMER/METAL/POLYMER271 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page