Skip to content

INTROCAN SAFETY® 3 4251130-02Recalls & reported problems

B. Braun Medical Inc. · Introcan Safety® 3 Closed IV Catheter 20 Ga. x 1.25 in., PUR, Winged · Class 2

All models of INTROCAN SAFETY 3 (5)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
7
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04046964014055), received between Apr 27, 2017 and Sep 12, 2025 — classified as 7 malfunctions.

The most frequently reported specific device problem is “Contamination /Decontamination Problem” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 1 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Contamination /Decontamination Problem2
  • Adverse Event Without Identified Device or Use Problem1
  • Break1
  • Difficult to Advance1
  • Fail-Safe Problem1
  • Leak/Splash1
  • Malposition of Device1

Patient problems

  • No Clinical Signs, Symptoms or Conditions4
  • Needle Stick/Puncture1
  • No Information1
  • Vasculitis1

Recent adverse event reports

The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.

  • MalfunctionSep 12, 2025Difficult to Advance; Fail-Safe Problem; Difficult to Advance; Fail-Safe Problem

    ACCORDING TO THE EVENT DESCRIPTION THE CATHETER PASSIVE SAFETY MECHANISM DID NOT ENGAGE WHEN REMOVING STYLETTE FROM PATIENT , ANOTHER WAS DIFFICULT TO THREAD. THE SAFETY THAT IS SUPPOSED TO ENGAGE WHEN REMOVED FROM THE PLASTIC CATHETER HOUSING WHEN REMOVING THE NEEDLE FROM THE PATIENT FAILED TO COVER THE SHARP END OF THE NEEDLE ON MULTIPLE NEEDLES FROM THIS SAME LOT NUMBER. A THIRD WAS DIFFICULT TO ADVANCE THE PLASTIC CATHETER OFF THE NEEDLE INTO THE VEIN.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 23036451 ↗
  • MalfunctionAug 5, 2025Contamination /Decontamination Problem; Contamination /Decontamination Problem

    AS REPORTED BY THE USER FACILITY: BRIEF INQUIRY DESCRIPTION DEFECTIVE PRODUCT INTROCAN 3. DETAILED INQUIRY DESCRIPTION THERE WERE SEVERAL NEW INTROCAN 3 PRODUCTS WITH DEBRIS ON THE CATHETER. IT APPEARED TO BE EXTRA MATERIAL FROM THE MOLDING PROCESS. THEY THREW THEM ALL AWAY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22715651 ↗
  • MalfunctionMay 28, 2025Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    ACCORDING TO THE EVENT DESCRIPTION, "PATIENT INTER TO UCI WITH SEPTIC DISRUPTIVE SHOCK, TRI-VALVULAR INSUFFICIENCY, URINARY TRACT INFECTION AND RENAL FAILURE HAVE PHLEBITIS AT THE SITE OF THE PUNCTION."

    Patient problems: Vasculitis

    MAUDE report 22097266 ↗
  • MalfunctionFeb 1, 2023Contamination /Decontamination Problem; Contamination /Decontamination Problem

    AS REPORTED BY THE USER FACILITY: IN RADIOLOGY DURING SCAN THEY WERE UNABLE TO FLUSH IV AND THOUGHT THERE WAS BLOCKAGE. THE NURSES HAD THE MD PUSH ON THE SYRINGE, AND HE WAS UNABLE TO. WHEN THEY PULLED BACK, THEY NOTICED SOME METAL COME INTO THE EXTENSION SET. NOTHING WAS SAVED NOR WERE ANY PICTURES TAKEN. THIS IV CATHETER IS NEW TO THEM, AND THEY THOUGHT THAT METAL WAS LEFT INSIDE THE HUB AFTER INSERTION. WE CONFIRMED HOW THE SAFETY MECHANISM WORK AND THAT IT WAS REMOVED DURING THE INITIAL IV INSERTION LEAVING NO METAL INSIDE. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16277588 ↗
  • MalfunctionAug 24, 2021Leak/Splash; Leak/Splash

    AS REPORTED BY THE USER FACTICITY: CUSTOMER JUST CONVERTED TO INTROCAN SAFETY 3. NURSE PLACED A 20G IN PATIENT. WHEN THREADING, STARTED TO DO A PUSH/PULL TECHNIQUE, AS IS CUSTOM WITH THEIR PREVIOUS DEVICE. BBRAUN EDUCATOR SHOWED THAT SHE SHOULD HOLD THE HUB WITH LEFT HAND AND REMOVE THE STYLET STRAIGHT OUT WITH RIGHT HAND. BBRAUN EDUCATOR IMMEDIATELY NOTICED A SLIGHT BLOOD LEAK FROM HUB. BY THE TIME THE EXTENSION SET WAS PLACED THERE WAS A SMALL AMOUNT OF BLOOD COMING OUT OF THE HUB. EXTENSION SET WAS PLACED WITHOUT DIFFICULTY AND THE CATHETER FUNCTIONED CORRECTLY.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12363625 ↗
  • MalfunctionFeb 8, 2018Break; Break

    AS REPORTED BY USER FACILITY: THE PATIENT WAS WINCING WHEN TRYING TO PLACE THE CATHETER. THE CATHETER WAS REMOVED AND IT WAS THEN NOTED THAT THE CATHETER HAD SHEARED IN THE MIDDLE. THE PATIENT WAS RESTUCK WITHOUT FURTHER INCIDENT.

    Patient problems: Needle Stick/Puncture

    MAUDE report 7251357 ↗
  • MalfunctionApr 27, 2017Malposition of Device; Malposition of Device

    AS REPORTED BY THE USER FACILITY (TRANSLATION OF USER FACILITY INFORMATION BY BBM SALES ORGANIZATION IN UNITED KINGDOM): PLASTIC TUBE WHICH SITS IN VEIN SNAPPED

    Patient problems: No Information

    MAUDE report 6525906 ↗

Other Catheter,intravascular,therapeutic,short-term less than 30 days devices

All Catheter,intravascular,therapeutic,short-term less than 30 days devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page