PROSPACE® XP SO147PRecalls & reported problems
Aesculap AG · PROSPACE XP IMPLANT 5° 7X8.5X26MM · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046964073717), received between Nov 29, 2021 and Nov 29, 2021 — classified as 1 injury.
The most frequently reported specific device problem is “Fracture” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Fracture1
Patient problems
- Failure of Implant1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryNov 29, 2021Fracture; Fracture
UPDATE: THE PROCEDURE WAS PERFORMED AT LEVEL L5-S1. THE PATIENT HAD SPINAL CANAL STENOSIS WITH NARROWING BETWEEN VERTEBRAL BODIES. IT WAS NOTED THAT USING A 7MM SHAVER DISTRACTOR ALONE WAS DIFFICULT, SO A CLAW- SHAPED DISTRACTOR WAS USED TO OPEN AND THEN LIFTED WITH 7MM. CAGE WAS INSERTED AFTER DISSECTION AND BONE FILLING. AT THE TIME OF INSERTING THE CAGE, THE IMAGE WAS CONFIRMED AND THE IMAGE WAS DRIVEN IN, AND THE MARKER POSITION AND THE INSERTER POSITION BECAME AN UNNATURAL IMAGE FROM THE MIDDLE. THE DAMAGED DEBRIS WAS COLLECTED AND THE TIP OF THE INSERTER WAS CONFIRMED TO BE DAMAGED. THE INSERTER ITSELF WAS NOT DAMAGED AND THE CAGE TIP 1/3 REMAINED IN THE PATIENT'S VERTEBRAL BODY. THE DOCTOR TRIED TO REMOVE IT USING A SPECIAL REMOVER, BUT IT WAS DIFFICULT TO REMOVE IT. FINALLY, THE TRAILING EDGE OF THE VERTEBRAL BODY WAS SCRAPED WITH A CHISEL AND OPENED USING A INGE LAMINA SPREADERS. THEN, IT WAS POSSIBLE TO RECOVER THE TIP OF THE CAGE BY REMOVING IT AGAIN WITH A SPECIAL REMOVER. AFTER THAT, THE SAME SIZE WAS INSTALLED IN THE OPEN STATE WITH A INGE LAMINA SPREADERS, AND IT WAS COMPLETED WITHOUT ANY PROBLEM.
Patient problems: Failure of Implant
MAUDE report 12888081 ↗
Other Intervertebral fusion device with bone graft, lumbar devices
- T-PAL 03.812.003Synthes GmbH · Intervertebral fusion device with bone graft, lumbar152 reports
- T-PAL 03.812.004Synthes GmbH · Intervertebral fusion device with bone graft, lumbar120 reports
- Catalyft PL Expandable Interbody System 6068073Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall66 reports
- Catalyft PL Expandable Interbody System 6069076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall51 reports
- Catalyft PL Expandable Interbody System 6068076Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall46 reports
- EIT TLIF Inserter TFT30101EIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Lumbar88 reports
- T-PAL 03.812.001Synthes GmbH · Intervertebral fusion device with bone graft, lumbar76 reports
- Catalyft PL Expandable Interbody System 6069096Medtronic Sofamor Danek, Inc. · Intervertebral fusion device with bone graft, lumbar1 recall25 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page