PTS® 613704Recalls & reported problems
B Braun Interventional Systems, Inc · PTS305 PTS BALLOON 30MM X 5CM X 80 CM · Class 2
Data updated Nov 27, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04046964310997), received between Jun 1, 2017 and Jun 1, 2017 — classified as 1 malfunction.
The most frequently reported specific device problem is “Kinked” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.
Most reported problems
Device problems
- Kinked1
- Material Rupture1
Patient problems
- No Code Available1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 1, 2017Kinked; Material Rupture
AS PER HOSPITAL MEDWATCH REPORT: "A MALE PATIENT WITH HISTORY OF BICUSPID AORTIC VALVE DISEASE STATUS POST ROSS PROCEDURE WITH RESULTING STENOTIC PULMONARY HOMOGRAFT ADMITTED FOR TRANSCATHETER PULMONARY VALVE REPLACEMENT. BALLOON SIZING OF THE PULMONARY ARTERY WITH DYNA CT PERFORMED WITH A 30 MM X 5 CM NUMED PERCUTANEOUS TRANSLUMINAL SIZING (PTS) SIZING BALLOON. BALLOON WAS ADVANCED INTO THE RIGHT VENTRICULAR OUTFLOW TRACT (RVOT) AND MAIN PULMONARY ARTERY AND INFLATED UNDER RAPID PACING. THE BALLOON RUPTURED AT LOW PRESSURE REQUIRING REMOVAL OF 16F SHEATH AND REPLACEMENT WITH A 16F SHORT COOK SHEATH AND THE BALLOON WAS SUCCESSFULLY RETRIEVED. THE PROCEDURE WAS ABORTED AND RESCHEDULED." ADDITION INFORMATION PER DISTRIBUTOR: "IT IS UNKNOWN WHETHER AN INFLATION DEVICE WITH PRESSURE GAUGE WAS USED. THE CATHETER SHAFT WAS KINKED. THERE WAS NOTHING UNUSUAL ABOUT THE PATIENT ANATOMY. THE PATIENT WAS STABLE POST PROCEDURE. THE BALLOON RUPTURED CIRCUMFERENTIALLY, IT IS UNKNOWN AT WHAT ATM THE BALLOON RUPTURED - THE REPORT STATES ONLY 'AT LOW PRESSURE'."
Patient problems: No Code Available
MAUDE report 6604958 ↗
FDA clearance and classification
Cleared through 510(k) K003320 on May 2, 2001 (decision: Substantially Equivalent). Submitted by NuMED, Inc. as “Pta-Os Sizing Balloon, Model 360”. The FDA review took 190 days. FDA record ↗
The FDA regulates product code MJN (catheter, intravascular occluding, temporary) under 21 CFR 870.4450 as a Class II device. 21 CFR 870.4450 ↗
Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.
Common questions about the PTS® 613704
Has the PTS® 613704 been recalled?
No FDA recall record in our data names this exact device identifier (DI 04046964310997), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.
What problems have been reported with the PTS® 613704?
The FDA's MAUDE database lists 1 adverse event report for this device, received on Jun 1, 2017. That report lists device problems “Kinked” (1) and “Material Rupture” (1). Reports are not verified by the FDA and do not prove the device caused the problem.
Have deaths or injuries been reported with the PTS® 613704?
None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.
Is the PTS® 613704 FDA approved?
It was cleared through 510(k) K003320 on May 2, 2001. Strictly, the FDA "clears" 510(k) devices as substantially equivalent to devices already on the market rather than "approving" them; approval is the PMA route.
Who makes the PTS® 613704, and is it still sold?
The FDA's device database lists B Braun Interventional Systems, Inc as the company responsible for it (brand PTS®, model 613704). Its record shows it as in commercial distribution.
Answers are built automatically from the FDA records on this page. They are not medical advice.
Other Catheter, intravascular occluding, temporary devices
- Pruitt F3 Carotid Shunt 2012-10Lemaitre Vascular, Inc. · Catheter, Intravascular Occluding, Temporary1 death158 reports
- GORE Molding Occlusion Balloon Catheter MOB37W. L. Gore & Associates, Inc. · Catheter, Intravascular Occluding, Temporary6 deaths152 reports
- Bridge Occlusion Balloon 590-001Spectranetics Corporation · Catheter, Intravascular Occluding, Temporary4 deaths57 reports
- Pruitt F3 Carotid Shunt e2012-10Lemaitre Vascular, Inc. · Catheter, Intravascular Occluding, Temporary53 reports
- Pruitt F3 Carotid Shunt 2013-10Lemaitre Vascular, Inc. · Catheter, Intravascular Occluding, Temporary46 reports
- Equalizer™ M001171100Boston Scientific Corporation · Catheter, intravascular occluding, temporary18 reports
- Pruitt F3 Carotid Shunt e2013-10Lemaitre Vascular, Inc. · Catheter, Intravascular Occluding, Temporary17 reports
- TRANSFORM M003SSC07070Stryker Corporation · Catheter, intravascular occluding, temporary17 reports
Sources and updates
- Device record: FDA GUDID, file dated Nov 27, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Nov 27, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Nov 27, 2026
- Clearance and classification: FDA 510(k), PMA and product classification databases, files dated Nov 27, 2026
- Page last rebuilt: Nov 27, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page