Skip to content

EASYPUMP 4540006-02Recalls & reported problems

B. Braun Medical Inc. · Easypump® LT 125-25-S · Class 2

Adverse event reports
21
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 21 adverse event reports that list this exact device (DI 04046964448454), received between Mar 28, 2017 and May 30, 2025 — classified as 21 malfunctions.

The most frequently reported specific device problem is “Excess Flow or Over-Infusion” (17 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 4 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 1 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520264
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Excess Flow or Over-Infusion17
  • Inaccurate Flow Rate4

Patient problems

  • No Clinical Signs, Symptoms or Conditions16
  • No Information2
  • Nausea1
  • No Consequences Or Impact To Patient1
  • No Known Impact Or Consequence To Patient1

Recent adverse event reports

The 21 most recent of 21 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMay 30, 2025Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    ACCORDING TO THE EVENT DESCRIPTION: THE FIRST INCIDENT DELIVERED MEDICATION SEVEN HOURS EARLIER THAN THE ADJUSTED TIME, WHILE THE SECOND INCIDENT DELIVERED IT 17 HOURS EARLIER.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22113392 ↗
  • MalfunctionDec 5, 2024Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    EVENT 1. ACCORDING TO THE EVENT DESCRIPTION: THERE WERE 4 DIFFERENT PATIENTS WHERE THE EASYPUMP WAS EMPTY AFTER 24 HOURS INSTEAD OF 72 HOURS. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20858599 ↗
  • MalfunctionDec 5, 2024Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    EVENT 3 ACCORDING TO THE EVENT DESCRIPTION: THERE WERE 4 DIFFERENT PATIENTS WHERE THE EASYPUMP WAS EMPTY AFTER 24 HOURS INSTEAD OF 72 HOURS. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20857748 ↗
  • MalfunctionDec 5, 2024Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    EVENT 4. ACCORDING TO THE EVENT DESCRIPTION: THERE WERE 4 DIFFERENT PATIENTS WHERE THE EASYPUMP WAS EMPTY AFTER 24 HOURS INSTEAD OF 72 HOURS. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20856292 ↗
  • MalfunctionDec 5, 2024Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    EVENT 2. ACCORDING TO THE EVENT DESCRIPTION: THERE WERE 4 DIFFERENT PATIENTS WHERE THE EASYPUMP WAS EMPTY AFTER 24 HOURS INSTEAD OF 72 HOURS. NO PATIENT COMPLICATIONS WERE REPORTED AS A RESULT OF THIS EVENT.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 20855133 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY. DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223732 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY: EVENT 2: DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223731 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY: EVENT 3: DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223730 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY: EVENT 1: DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223721 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY: EVENT 6: DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223720 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY. EVENT 7. DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223719 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY: EVENT 8: DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223718 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY: EVENT 5: DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223717 ↗
  • MalfunctionJan 23, 2023Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY: EVENT 9: DETAILED INQUIRY DESCRIPTION: INFUSION STOPPED AT 12 HRS RATHER THAN 25 HRS. NO INJURY REPORTED.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16223716 ↗
  • MalfunctionNov 30, 2021Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY / TRANSLATION OF USER FACILITY INFORMATION BY BBM SALES ORGANIZATION IN (B)(6): EVENT 2: "OVERINFUSIONT" "EASYPUMP RUNS EMPTY AFTER 12 HOURS INSTEAD OF 24 HOURS. THE DOCTOR'S OFFICE DISCARDED THE SAMPLE CONTAMINATED WITH CYTO. THE PHARMACY HAS BUT TESTED A SAMPLE WITH NACL, WHICH ALSO RAN TOO FAST. THIS SAMPLE CONTAMINATED WITH NACL CONTAMINATED SAMPLE AND ANOTHER ORIGINAL PACKED SAMPLE ARE SENT IN."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12891192 ↗
  • MalfunctionNov 30, 2021Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY THE USER FACILITY / TRANSLATION OF USER FACILITY INFORMATION BY BBM SALES ORGANIZATION IN (B)(6): EVENT 1: "OVERINFUSIONT" "EASYPUMP RUNS EMPTY AFTER 12 HOURS INSTEAD OF 24 HOURS. THE DOCTOR'S OFFICE DISCARDED THE SAMPLE CONTAMINATED WITH CYTO. THE PHARMACY HAS BUT TESTED A SAMPLE WITH NACL, WHICH ALSO RAN TOO FAST. THIS SAMPLE CONTAMINATED WITH NACL CONTAMINATED SAMPLE AND ANOTHER ORIGINAL PACKED SAMPLE ARE SENT IN."

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 12891183 ↗
  • MalfunctionNov 22, 2019Excess Flow or Over-Infusion; Excess Flow or Over-Infusion

    AS REPORTED BY USER FACILITY: INFUSIONS ARE ENDING 6 TO 12 HOURS EARLY.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 9365570 ↗
  • MalfunctionDec 4, 2018Inaccurate Flow Rate; Inaccurate Flow Rate

    AS REPORTED BY THE USER FACILITY (TRANSLATION OF USER FACILITY INFORMATION BY BBM SALES ORGANIZATION IN GERMANY): SOLUTION / FAST FLOW

    Patient problems: No Information

    MAUDE report 8130335 ↗
  • MalfunctionOct 31, 2018Inaccurate Flow Rate; Inaccurate Flow Rate

    AS REPORTED BY THE USER FACILITY (TRANSLATION OF USER FACILITY INFORMATION BY BBM SALES ORGANIZATION IN FRANCE: PUMP-FLOW RATE-FAST

    Patient problems: Nausea

    MAUDE report 8025644 ↗
  • MalfunctionApr 3, 2017Inaccurate Flow Rate; Inaccurate Flow Rate

    AS REPORTED BY THE USER FACILITY (TRANSLATION OF USER FACILITY INFORMATION BY BBM SALES ORGANIZATION IN FRANCE): PUMP-FLOW RATE-FAST

    Patient problems: No Information

    MAUDE report 6454000 ↗
  • MalfunctionMar 28, 2017Inaccurate Flow Rate; Inaccurate Flow Rate

    AS REPORTED BY THE USER FACILITY (TRANSLATION OF USER FACILITY INFORMATION BY BBM SALES ORGANIZATION IN GERMANY): FAST FLOW

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 6440627 ↗

Other PUMP, INFUSION, ELASTOMERIC devices

All PUMP, INFUSION, ELASTOMERIC devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.