APEX™ 601224Recalls & reported problems
B. Braun Medical Inc. · APEX, CONTROL MODULE · Class 2
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04046964801068), received between Apr 12, 2019 and Sep 3, 2019 — classified as 2 malfunctions.
The most frequently reported specific device problem is “Application Program Problem: Dose Calculation Error” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Application Program Problem: Dose Calculation Error2
Patient problems
- No Patient Involvement2
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 3, 2019Application Program Problem: Dose Calculation Error; Application Program Problem: Dose Calculation Error
AS PER USER FACILITY: CUSTOMER REPORTED THEY HAD ADDED THE NEW SMOFLIPID TO THEIR SCDM DATABASE EARLIER IN THE DAY BUT THE COMPOUNDER WAS NOT PUMPING THE CORRECT AMOUNT FOR THE PATIENT ORDER. THE COMPOUNDER WAS PUMPING WATER INSTEAD OF THE SMOFLIPID SOLUTION. NO PATIENT INVOLVEMENT.
Patient problems: No Patient Involvement
MAUDE report 8955177 ↗MalfunctionApr 12, 2019Application Program Problem: Dose Calculation Error; Application Program Problem: Dose Calculation Error
AS PER USER FACILITY: CUSTOMER REPORTED AN ENCOUNTER AN ISSUE WHERE WHEN THE UNIVERSAL INGREDIENT (UI) IS SELECTED TO BE SOMETHING OTHER THAN WATER AND THE CONTAINER IS CHANGED DURING A MANIFOLD FLUSH THE SOFTWARE CHANGES THE UI TO LINE 1 WATER. IN THIS CASE THE UI WAS LINE 3 TROPHAMINE AND IT CHANGED TO LINE 1 WATER WHEN THE TROPHAMINE CONTAINER WAS CHANGED. THE UI WAS CHANGED BACK TO TROPHAMINE BY THE OPERATOR AND COMPOUNDING WAS ABLE TO CONTINUE. NO PATIENT INVOLVEMENT.
Patient problems: No Patient Involvement
MAUDE report 8508402 ↗
Other SYSTEM/DEVICE, PHARMACY COMPOUNDING devices
- EXACTAMIX H938175Baxter Healthcare Corporation · SYSTEM/DEVICE, PHARMACY COMPOUNDING3 recalls263 reports
- EXACTAMIX H938174Baxter Healthcare Corporation · SYSTEM/DEVICE, PHARMACY COMPOUNDING2 recalls238 reports
- B.BRAUN 2112550B. Braun Medical Inc. · SYSTEM/DEVICE, PHARMACY COMPOUNDING74 reports
- EXACTAMIX EXM12DYBaxter Healthcare Corporation · System/device, pharmacy compounding1 recall0 reports
- ABACUS 83003393Baxter Healthcare Corporation · SYSTEM/DEVICE, PHARMACY COMPOUNDING1 recall0 reports
- ABACUS 83003391Baxter Healthcare Corporation · SYSTEM/DEVICE, PHARMACY COMPOUNDING1 recall0 reports
- ABACUS 83003392Baxter Healthcare Corporation · SYSTEM/DEVICE, PHARMACY COMPOUNDING1 recall0 reports
- IVX StationOmnicell, Inc. · System/Device, Pharmacy Compounding1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.