CP Stent™ 614310Recalls & reported problems
B Braun Interventional Systems, Inc · COVERED CP STENT 8Z 3.9CM · Class 3 · Implant
All models of CP Stent (16)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 3
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 3 adverse event reports that list this exact device (DI 04046964898914), received between Dec 15, 2016 and Sep 4, 2019 — classified as 3 malfunctions.
The most frequently reported specific device problem is “Detachment of Device or Device Component” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Detachment of Device or Device Component2
- Detachment Of Device Component1
- Malposition of Device1
Patient problems
- No Known Impact Or Consequence To Patient3
Recent adverse event reports
The 3 most recent of 3 reports, in the reporter's own words as published by the FDA.
MalfunctionSep 4, 2019Detachment of Device or Device Component
AS PER THE REPORT FROM THE HOSPITAL / DISTRIBUTOR - THE SLEEVE DETACHED AND BEGAN TO SLIP OFF THE STENT WHEN CRIMPING ONTO THE BIB. THE INDICATION THE PHYSICIAN WAS USING THE PRODUCT FOR: COARCTATION OF THE AORTA. THE BALLOON THE STENT WAS BEING MOUNTED ON: BB033. THEY DID NOT COMPLETELY MOUNT THE STENT DUE TO THE SLEEVE SEPARATING FROM THE STENT. THEY PLACED ANOTHER CP STENT WITH SUCCESS. THE STANDARD PROCESS OF CRIMPING WAS USED. THE BLUE INTRODUCER TOOL PROVIDED BY NUMED WAS NOT USED. THEY DID NOT ATTEMPT TO PULL THE STENT BACK THROUGH THE HEMOSTASIS VALVE AT ANY TIME. SALINE WAS USED DURING PREP. THERE WAS NOTHING UNUSUAL ABOUT THE PATIENT ANATOMY. THE CATHETER SHAFT WAS NOT KINKED.
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 8961013 ↗MalfunctionAug 31, 2018Detachment of Device or Device Component
AS REPORTED BY BIS "TEFLON COVER DETACHED FROM THE STENT. THE INDICATION THE PHYSICIAN WAS USING THE PRODUCT FOR: COARCTATION REPAIR. THE BALLOON THE STENT WAS MOUNTED ON: 12X4 BIB. THE CRIMPING PROCESS USED: CRIMPED USING UMBILICAL TAPE AND LIGHT FINGER PRESSURE. THE RING MANDRIL WAS USED DURING THE CRIMPING PROCESS. THE STENT DID NOT SLIP. THE COVERING BECAME DETACHED AS THE BIB/STENT WAS BEING ADVANCED INTO THE SHEATH USING THE LOADER PROVIDED WITH THE STENT. THERE WAS NO DIFFICULTY ENCOUNTERED WHILE INSERTING THE BIB/STENT INTO THE INTRODUCER. THE BLUE INTRODUCER TOOL PROVIDED BY NUMED WAS USED. ACCOUNT DID NOT ATTEMPT TO PULL THE STENT BACK THROUGH THE HEMOSTASIS VALVE. SALINE MEDIA WAS USED DURING PREP. THE BALLOON WAS NOT INFLATED. A 9F INTRODUCER SHEATH WAS USED. THERE WAS NOTHING UNUSUAL ABOUT THE PATIENT ANATOMY. THE CATHETER SHAFT WAS NOT KINKED. THE PATIENT CONDITION POST PROCEDURE WAS NORMAL". "THE 12F HEMOSTASIS TOOL WAS USED".
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7838037 ↗MalfunctionDec 15, 2016Detachment Of Device Component; Malposition of Device
AS PER THE REPORT FROM THE DISTRIBUTOR: "DURING DELIVERY, THE STENT WAS NOTICED TO BE SHIFTED FROM THE BALLOON. WHEN THE PHYSICIAN TRIED TO WITHDRAW THE SYSTEM TO REPOSITION THE STENT, THE COVER FELL OFF."
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6177165 ↗
Other Aortic stent devices
- Minima Stent System - 6mm FG-0001Renata Medical, Inc. · Aortic Stent1 death10 reports
- CP Stent™ 614311B Braun Interventional Systems, Inc · Aortic stent6 reports
- CP Stent™ 614309B Braun Interventional Systems, Inc · Aortic stent3 reports
- CP Stent™ 614308B Braun Interventional Systems, Inc · Aortic stent3 reports
- Minima Stent System - 8mm FG-0002Renata Medical, Inc. · Aortic Stent2 reports
- CP Stent™ 614376B Braun Interventional Systems, Inc · Aortic stent2 reports
- CP Stent™ 614516B Braun Interventional Systems, Inc · Aortic stent2 reports
- CP Stent™ 614375B Braun Interventional Systems, Inc · Aortic stent1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page