DIPLOMAT Percutaneous tulipRecalls & reported problems

SIGNUS Medizintechnik GmbH · The modular DIPLOMAT® pedicle screw system is a rod-screw system that firmly connects two or more screws via the screw head and a rod using a force-fit or form-fit connection. Additional fixation elements, such as cross bars, hooks, connectors and washers, can also be used. The DIPLOMAT® pedicle screw system is applied temporarily to provide internal posterior stabilization until bone fusion in the lumbar or thoracic spine has taken place. The surgeon makes the final decision as to the indwelling time of the implant in the patient‘s body and the time when the implant is to be explanted. The pedicle screw system is implanted from a posterior approach. The implant is screwed into the vertebral body via the pedicle and it can be applied in a single segment or multiple segments. Implantation is facilitated by use of the specially developed accessories for inserting and positioning the implants. Only these accessories ensure safe use. Our product information provides further system-related information on the surgical method. If there are any preoperative uncertainties relating to the implant, information must be obtained from SIGNUS. Instruments specially developed by SIGNUS to ensure safe application are available for use with the implant system. · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
4
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 4 adverse event reports that list this exact device (DI 04047844023778), received between Apr 30, 2019 and Mar 14, 2024 — classified as 4 malfunctions.

The most frequently reported specific device problem is “Misassembled” (2 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 1 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Misassembled2
  • Misassembly by Users2
  • Use of Device Problem2
  • Device Slipped1
  • Material Twisted/Bent1

Patient problems

  • No Code Available2
  • Failure of Implant1
  • Pain1

Recent adverse event reports

The 4 most recent of 4 reports, in the reporter's own words as published by the FDA.

  • MalfunctionMar 14, 2024Material Twisted/Bent; Material Twisted/Bent

    SURGEON REPORTED ABOUT THE POST-SURGERY X-RAY FOR A 2 LEVEL MIS CASE ( L4-L5-S1) USING DIPLOMAT . THE X-RAY FILM INDICATES THAT THE DIPLOMAT MIS TULIP WAS NOT ATTACHED TO THE PEDICLE SCREW HEAD AT S1 POSITION. THERE WAS NO DIFFICULTY REPORTED DURING THE OPERATION. THE PATIENT WAS REPORTED WITH LITTLE PAIN (POSSIBLE CAUSES ARE SURGERY OR DETACHED IMPLANT). DISASSEMBLY OF IMPLANT COMPONENTS AND PAIN AREKNOWN RISKS/SIDE EFFECTS INDICATED IN THE IFU.

    Patient problems: Pain

    MAUDE report 18901900 ↗
  • MalfunctionApr 30, 2019Misassembled; Use of Device Problem; Misassembly by Users; Misassembled; Use of Device Problem; Misassembly by Users

    AFTER SEVERAL COMPLAINTS ABOUT BENT MOBIS INSERTERS BECAUSE OF IMPROPER USE OF THE DEVICE AN APPLIED PRACTICE (AP31) WAS ADDED TO PRODUCT INFORMATION.

    Patient problems: No Code Available

    MAUDE report 8564023 ↗
  • MalfunctionApr 30, 2019Misassembled; Use of Device Problem; Misassembly by Users; Misassembled; Use of Device Problem; Misassembly by Users

    REVISION SURGERY BECAUSE OF IMPROPER APPLICATION OF THE TULIP ON THE SCREW BY THE SURGEON WITHIN THE INITIAL SURGERY. THE PEDICLE SCREW NEVER WAS PROPERLY CONNECTED TO THE TULIP. THE FLAWED IMAGE OF THE TULIP'S HIGHLY INWARD-POINTING PLATE CLEARLY INDICATES THAT THE HEAD OF THE PEDICLE SCREW WAS NOT FIRMLY ATTACHED TO THE TULIP SADDLE. THE CONTROL OF THE TIGHTNESS OF THE TULIP ON THE PEDICLE SCREW DESCRIBED IN THE SURGICAL GUIDE WAS PROBABLY NOT DONE. THE SAME EFFECT OCCURS WHEN THE TULIP IS PLACED IN SITU AFTER THE PEDICLE SCREW HAS BEEN SET. IT INDICATES THAT THE PEDICLE SCREW WAS INSERTED QUITE DEEPLY INTO THE PEDICLE, SO THAT A COMPLETE GRASPING OF THE TULIP PLATELETS AROUND THE PEDICLE HEAD WAS NOT POSSIBLE DURING THE SUBSEQUENT PLACEMENT OF THE TULIP. THE INCORRECT PLACEMENT OF THE TULIP ON THE SCREW HEAD CAN THUS LEAD ALREADY DURING THE ATTACHMENT OF THE ROD FOR PUSHING OUT OF THE PEDICLE HEAD OF THE TULIP. THE HEAD OF THE PEDICLE SCREW THEN VERY PROBABLY BENT THE LEAFLETS OF THE TULIP'S SADDLE WHEN MOBILIZING THE PATIENT AND LATER SLIPPED OUT OF THE TULIP. BY OVERLAYING THE TULIPS AND PEDICLE SCREWS IN THE X-RAY IMAGE IN LATERAL VIEW, THIS SLIPPING OUT WAS NOT RECOGNIZED BY

    Patient problems: No Code Available

    MAUDE report 8563936 ↗
  • MalfunctionApr 30, 2019Device Slipped

    LITERATURE "EXPERIENCE WITH A MODULAR PEEK SYSTEM FOR CERVICAL VERTEBRAL BODY REPLACEMENT" BY KONIG SA1, SPETZGER U REPORTED. "THE AUTHORS PERFORMED 13 ONE-LEVEL AND 7 TWO-LEVEL CORPECTOMIES; FROM THE LETTER GROUP THERE WERE 2 REVISION CASES (10%) WITH IMPLANT DISLOCATION. FOUR CASES (20%) OF SECONDARY SUBSIDENCE ..." THE STATEMENT (KÖNIG ET AL.2015) MADE BY THE AUTHORS CANNOT BE RECONSTRUCTED FROM THE DATA AVAILABLE HERE. FURTHER DATA ARE NECESSARY FOR AN OBJECTIVE ASSESSMENT. FIRST, THE AUTHORS WOULD HAVE HAD TO CHANGE THE STRUCTURE OF THEIR RETROSPECTIVE CASE SERIES. IN THE RETROSPECTIVE CASE SERIES DESCRIBED HERE, THE PATIENTS WERE DIVIDED INTO 2 GROUPS. THE FIRST GROUP CONSISTS OF 13 PATIENTS WITH A 1 LEVEL CORPECTOMY WERE PERFORMED. THE SECOND GROUP CONSISTS OF 7 PATIENTS IN WHOM A 2-LEVEL CORPECTOMY WAS PERFORMED. IN ALL CASES THE IMPLANT ATHLETE WAS USED. IN ORDER TO MAKE AN OBJECTIVE ASSESSMENT, THE AUTHORS WOULD HAVE HAD TO COMPARE THE RESULTS OF THE SAME NUMBER OF PATIENTS PER GROUP WITH THE ATHLETE IMPLANT AND FOR EXAMPLE WITH THE ILIAC CREST. THE NUMBER OF 20 PATIENTS IS ALSO TOO SMALL TO MAKE A SIGNIFICANT STATEMENT. IN THE SUMMARIES OF THE FOLLOWING PUBLICATIONS, WHI

    Patient problems: Failure of Implant

    MAUDE report 8563851 ↗

Other Orthosis, Spinal Pedicle Fixation devices

All Orthosis, Spinal Pedicle Fixation devices →