ENDOMAT 20330320-1Recalls & reported problems
Karl Storz GmbH & Co. KG · ENDOMAT® LC SCB, Roller Pump · Class 2
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04048551066423), received between Oct 11, 2017 and Nov 15, 2019 — classified as 1 injury, 1 malfunction.
The most frequently reported specific device problem is “Misassembled” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Misassembled2
Patient problems
- No Consequences Or Impact To Patient2
- No Code Available1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryNov 15, 2019Misassembled; Misassembled
ALLEGEDLY, APPROXIMATELY 2/3 OF THE WAY INTO A TURP PROCEDURE, THE ENDOMAT SUCTION PUMP WAS HOOKED UP; HOWEVER, THE PUMP TUBING WAS PLACED INCORRECTLY INTO THE PUMP, RESULTING IN THE FLUID INSIDE THE CANNISTER TO BE PUMPED BACK INTO THE PATIENT'S BLADDER. THIS CAUSED OVER-DISTENSION, INCREASED PRESSURE, AND FLUID RETENTION. POST-OP, THE PATIENT WAS KEPT IN ICU FOR A LONGER TIME THAN PLANNED TO MONITOR THE FLUID RETENTION CONDITION. THE PATIENT HAS BEEN RELEASED, AND HOSPITAL CONFIRMED THERE IS NO LONG-TERM IMPACT TO THE PATIENT.
Patient problems: No Code Available; No Consequences Or Impact To Patient
MAUDE report 9329203 ↗MalfunctionOct 11, 2017Misassembled; Misassembled
ALLEGEDLY, DURING A TURP PROCEDURE, THE ENDOMAT PUMP TUBING WAS MISTAKENLY HOOKED UP BACKWARDS. THE DOCTOR NOTICED THE FLUID WAS COMING INFLOW INSTEAD OF OUTFLOW. THE HOSPITAL DID NOT BELIEVE THE WASTE FLUID REACHED THE PATIENT'S BLADDER BUT, AS A PRECAUTION, IV ANTIBIOTICS WERE ADMINISTERED TO THE PATIENT. HOSPITAL REPORTED THE PATIENT IS DOING FINE.
Patient problems: No Consequences Or Impact To Patient
MAUDE report 6942963 ↗
Other endoscopic irrigation/suction system devices
- OrcaPod™ SUV-628Boston Scientific Corporation · endoscopic irrigation/suction system79 reports
- 2-piece valve kit (Suction and Air/Water Valve) EN10229.2GA Health Company Limited · Endoscopic Irrigation/Suction System1 recall0 reports
- ERBEFLO CleverCap® 20325-201Erbe Medical, LLC · Endoscopic Irrigation/Suction System1 recall0 reports
- andorate® A/W Channel Cleaning Adapter + 4-piece Valve Kit GAR3846GA Health Company Limited · Endoscopic Irrigation/Suction System1 recall0 reports
- Suction Valve EN10232GA Health Company Limited · Endoscopic Irrigation/Suction System1 recall0 reports
- ERBEFLO CleverCap® 20325-203Erbe Medical, LLC · Endoscopic Irrigation/Suction System1 recall0 reports
- BullDog® 1203-71Diversatek Healthcare, Inc. · Endoscopic Irrigation/Suction System1 recall0 reports
- ERBEFLO® 2 20325-222Erbe Medical, LLC · Endoscopic Irrigation/Suction System1 recall0 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.