S-PILOT UP501Recalls & reported problems
Karl Storz GmbH & Co. KG · S-PILOT · Class 2
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 7
- Deaths reported
- 2
- Injuries reported
- 5
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 7 adverse event reports that list this exact device (DI 04048551354155), received between Jul 11, 2023 and Apr 24, 2026 — classified as 2 deaths, 5 injuries.
The most frequently reported specific device problem is “Insufficient Device Problem Information” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Insufficient Device Problem Information2
- Mechanical Problem2
- Power Problem2
- Adverse Event Without Identified Device or Use Problem1
- Improper Flow or Infusion1
- Mechanical Jam1
- Unexpected Shutdown1
Patient problems
- Insufficient Information4
- Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available2
- No Clinical Signs, Symptoms or Conditions1
- Pulmonary Edema1
Recent adverse event reports
The 7 most recent of 7 reports, in the reporter's own words as published by the FDA.
InjuryApr 24, 2026Mechanical Jam
IT WAS REPORTED THAT THE VALVE DID NOT OPEN DURING THE PROCEDURE. CONSEQUENTLY, THE SUCTION DID NOT WORK, AND THEY HAD TO CONVERT TO BIPOLAR IN ORDER TO REMOVE THE PROSTATE ADENOMA, WHICH PROLONGED THE PROCEDURE BY MORE THAN TWO HOURS. SINCE THE PROCEDURE WAS PROLONGED BY TWO HOURS, THE CASE IS DEEMED REPORTABLE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 24988226 ↗InjuryAug 6, 2025Mechanical Problem; Improper Flow or Infusion; Mechanical Problem
THE FOLLOWING WAS REPORTED: AT THE START OF SURGERY, THE PINCH VALVE OF THE PRODUCT REMAINED OPEN, AND ATTEMPTS TO TURN THE POWER ON AND OFF DID NOT IMPROVE THE SITUATION.
Patient problems: Insufficient Information
MAUDE report 22730364 ↗InjuryAug 6, 2025Mechanical Problem; Mechanical Problem
THE FOLLOWING WAS REPORTED: AT THE START OF SURGERY, THE PINCH VALVE OF THE PRODUCT REMAINED OPEN, AND ATTEMPTS TO TURN THE POWER ON AND OFF DID NOT IMPROVE THE SITUATION.
Patient problems: Insufficient Information
MAUDE report 22730201 ↗DeathMar 24, 2025Power Problem; Unexpected Shutdown; Power Problem; Unexpected Shutdown
IT WAS REPORTED THAT "THE INITIAL CHECKS WERE DONE, THE S-PILOT WAS WORKING, INTRA-OPERATIVELY POWER COULD NOT BE ESTABLISHED. A PROLONGED MORCELLATION TIME WAS INDICATED. THE WHOLE PROCEDURE WAS PROLONGED MORE THAN 60 MINUTES. AS CONSEQUENCE, FURTHER INTERVENTIONS WERE REQUIRED (CT SCAN, X-RAY AND ITU ADMISSION) AND THEREFORE ADDITIONAL HOSPITALIZATION NECESSARY. IN ADDITION, ON (B)(6) 2025 THE INFORMATION WAS RECEIVED THAT THE PATIENT HAS PASSED AWAY.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available; Pulmonary Edema
MAUDE report 21681389 ↗DeathMar 24, 2025Power Problem; Power Problem
IT WAS REPORTED THAT, THE INITIAL CHECKS WERE DONE, THE S-PILOT WAS WORKING, INTRA-OPERATIVELY POWER COULD NOT BE ESTABLISHED. A PROLONGED MORCELLATION TIME WAS INDICATED. THE WHOLE PROCEDURE WAS PROLONGED MORE THAN 60 MINUTES. AS CONSEQUENCE, FURTHER INTERVENTIONS WERE REQUIRED (CT SCAN, X-RAY AND ITU ADMISSION) AND THEREFORE ADDITIONAL HOSPITALIZATION NECESSARY. IN ADDITION, ON 2025-03-19, THE INFORMATION WAS RECEIVED THAT THE PATIENT HAS PASSED AWAY.
Patient problems: Appropriate Clinical Signs, Symptoms and Conditions Term/Code Not Available
MAUDE report 21679543 ↗InjuryJul 11, 2023Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information
IT WAS REPORTED THAT THE UP501 DID NOT WORK DURING THE PROCEDURE. THE PROCEDURE HAD TO BE ABORTED AND WAS CONTINUED AFTER TWO DAYS.
Patient problems: Insufficient Information
MAUDE report 17298876 ↗InjuryJul 11, 2023Insufficient Device Problem Information; Insufficient Device Problem Information
IT WAS REPORTED THAT THE UP501 DID NOT WORK DURING THE PROCEDURE. THE PROCEDURE HAD TO BE ABORTED AND WAS CONTINUED AFTER TWO DAYS.
Patient problems: Insufficient Information
MAUDE report 17298872 ↗
Other APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED devices
- StrykeFlow 0250070520Stryker Corporation · APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED2 recalls250 reports
- StrykeFlow 0250070505Stryker Corporation · APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED1 recall3 reports
- Altitude 8888571370Cardinal Health 200, LLC · APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED1 recall0 reports
- Aqua-Seal 8888571315Cardinal Health 200, LLC · APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED1 recall0 reports
- Sentinel Seal 8888571513Cardinal Health 200, LLC · APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED1 recall0 reports
- Sentinel Seal 8888571562Cardinal Health 200, LLC · APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED1 recall0 reports
- spineX BONE DUST COLLECTOR S-4500Oto-Med, Inc. · Apparatus, Suction, Operating-Room, Wall Vacuum Powered1 recall0 reports
- CRD 65651-510Cardinal Health 200, LLC · APPARATUS, SUCTION, OPERATING-ROOM, WALL VACUUM POWERED1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page