Skip to content

CALLISTO eye Panel PC Model IIRecalls & reported problems

Carl Zeiss Meditec AG · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04049539103512), received between Nov 10, 2017 and Nov 10, 2017 — classified as 1 injury.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Adverse Event Without Identified Device or Use Problem1

Patient problems

  • No Code Available1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryNov 10, 2017Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    THE HEALTH CARE PROFESSIONAL (HCP) REPORTED THAT A TORIC IOL WAS IMPLANTED IN THE PATIENT'S RIGHT EYE 90 DEGREES OFF THE DESIRED AXIS. THE MARKERLESS FUNCTION OF THE CALLISTO EYE HAD BEEN USED TO POSITION THE IOL. THE PATIENT'S ASTIGMATIC OUTCOME WAS ABOUT 6.0 DIOPTERS, WHICH RESULTED IN POOR VISUAL ACUITY. THE HCP DECIDED TO PERFORM A FOLLOW-UP SURGERY USING THE CALLISTO EYE TO RE-POSITION THE IOL. AFTER THE CORRECTIVE TREATMENT, THE PATIENT'S ASTIGMATISM IS ABOUT 0.25 DIOPTERS.

    Patient problems: No Code Available

    MAUDE report 7023374 ↗

FDA clearance and classification

The FDA regulates product code LMD (system, digital image communications, radiological) under 21 CFR 892.2020 as a Class I device. 21 CFR 892.2020 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: A medical image communications device provides electronic transfer of medical image data between medical devices. It may include a physical communications medium, modems, interfaces, and a communications protocol. It may provide simple image review software functionality for medical image processing and manipulation, such as grayscale window and level, zoom and pan, user delineated geometric measurements, compression, or user added image annotations. The device does not perform advanced image processing or complex quantitative functions.

Common questions about the CALLISTO eye Panel PC Model II

Has the CALLISTO eye Panel PC Model II been recalled?

No FDA recall record in our data names this exact device identifier (DI 04049539103512), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the CALLISTO eye Panel PC Model II?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Nov 10, 2017. Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the CALLISTO eye Panel PC Model II?

None of the reports are classified as deaths, 1 as an injury and 0 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the CALLISTO eye Panel PC Model II FDA approved?

Devices of this type (product code LMD) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Carl Zeiss Meditec AG.

Who makes the CALLISTO eye Panel PC Model II, and is it still sold?

The FDA's device database lists Carl Zeiss Meditec AG as the company responsible for it (brand CALLISTO eye Panel PC, model Model II). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other System, Digital Image Communications, Radiological devices

All System, Digital Image Communications, Radiological devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page