Skip to content

NA 8735685Recalls & reported problems

Richard Wolf GmbH · FLEX. GRASP. FORCEPS 5FR WL 550MM double action, TL 700 mm, non-dismantling, reusable · Class 1

Data updated Nov 27, 2026 from official FDA records · Editorial policy

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04055207020265), received between Jul 19, 2022 and Jul 19, 2022 — classified as 1 malfunction.

The most frequently reported specific device problem is “Deformation Due to Compressive Stress” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Recalls naming this device

  1. Mar 24, 2023Class IIOpen, Classified

    Potentially unable to open forceps jaws when the endoscope shaft is bent by about 90 degrees. If, in addition, the proximal forceps shaft is bent, the forceps can no longer be opened or restrictions begin even with a slight bending of the endoscope.

    Z-1424-2023 · Root cause: Under Investigation by firm · Recall details · FDA record ↗

Most reported problems

Device problems

  • Deformation Due to Compressive Stress1
  • Material Twisted/Bent1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJul 19, 2022Deformation Due to Compressive Stress; Material Twisted/Bent; Deformation Due to Compressive Stress; Material Twisted/Bent

    RICHARD WOLF GMBH COMPLAINT REFERENCE (B)(4). IT WAS REPORTED TO RICHARD WOLF GMBH. (RWGMBH) THAT "WHEN TRYING TO REMOVE A DJ SPLINT(CATHETER), THE FORCEPS COULD NO LONGER BE TURNED OR OPENED. THE OPERATION WAS ABORTED. THE PATIENT DID NOT SUFFER ANY CONSEQUENCES." RWGMBH AWARENESS DATE, (B)(6) 2022.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 15058126 ↗

FDA clearance and classification

The FDA regulates product code FCL (forceps, biopsy, non-electric) under 21 CFR 876.1075 as a Class I device. 21 CFR 876.1075 ↗

Devices of this type are generally exempt from premarket notification (510(k)), so a model can be sold without an FDA clearance of its own; it still has to meet FDA registration, labeling and reporting rules.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the NA 8735685

Has the NA 8735685 been recalled?

Yes. 1 FDA recall record names this device's identifier, and it is still open. The recall, Z-1424-2023 (Class II), began on Mar 24, 2023: Potentially unable to open forceps jaws when the endoscope shaft is bent by about 90 degrees. If, in addition, the proximal forceps shaft is bent, the forceps can no longer be opened or restrictions begin even with a… If you use this device, follow the manufacturer's notice and your healthcare provider's advice.

What problems have been reported with the NA 8735685?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Jul 19, 2022. That report lists device problems “Deformation Due to Compressive Stress” (1) and “Material Twisted/Bent” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the NA 8735685?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the NA 8735685 FDA approved?

Devices of this type (product code FCL) are generally exempt from FDA premarket notification, so this model has no FDA clearance number of its own. It is listed in the FDA's device database (GUDID) by Richard Wolf GmbH.

Who makes the NA 8735685, and is it still sold?

The FDA's device database lists Richard Wolf GmbH as the company responsible for it (brand NA, model 8735685). Its record shows it as in commercial distribution.