- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04056481000462), received between Jun 18, 2018 and Jun 18, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device Handling Problem” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K092467); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Device Handling Problem1
- Improper or Incorrect Procedure or Method1
- Use of Device Problem1
Patient problems
- Cerebrospinal Fluid Leakage1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 18, 2018Use of Device Problem; Improper or Incorrect Procedure or Method; Device Handling Problem; Use of Device Problem; Improper or Incorrect Procedure or Method; Device Handling Problem
A FUNCTIONAL ENDOSCOPIC SINUS SURGERY (FESS) WAS PERFORMED WITH THE AID OF THE BRAINLAB ENT NAVIGATION SYSTEM VERSION 3.1. THE SURGICAL AREA INCLUDED ANATOMY NEAR THE SKULL BASE. DURING THE PROCEDURE THE SURGEON: POSITIONED THE PATIENT IN SUPINE ORIENTATION AND ATTACHED THE REFERENCE HEADBAND AND REFERENCE ARRAY FOR NAVIGATION. PERFORMED THE INITIAL PATIENT REGISTRATION ON THE PRE-OP CT WITH REGISTRATION POINTS TAKEN ON THE SKIN OF THE PATIENT TO MATCH THE DISPLAY OF THE NAVIGATION TO THE CURRENT PATIENT ANATOMY. VERIFIED THE ACCURACY OF THE REGISTRATION ON THE PATIENT'S SKIN WITH ANATOMICAL LANDMARKS, AND JUDGED THE NAVIGATION ACCURACY ACHIEVED LESS THAN OPTIMAL, BUT ACCEPTABLE FOR USE FOR THIS CASE. STARTED THE SURGERY USING AN ENDOSCOPE, CALIBRATED (NON-BRAINLAB) INSTRUMENTS TO THE NAVIGATION TO USE NAVIGATION ONCE BEING NEAR CRITICAL STRUCTURES. NOTED THAT THE INSTRUMENT POSITION DISPLAYED BY NAVIGATION DID NOT MATCH THE IMAGE FROM THE ENDOSCOPE, AND DETERMINED THAT THE NAVIGATION DISPLAY DEVIATED BY CA. 3 MM. CONTINUED THE SURGERY WITH NAVIGATION. WHEN USING AN SHARP-EDGE INSTRUMENT CALIBRATED TO NAVIGATION AS A PROBE, UNINTENTIONALLY THE BASE OF THE PATIENT'S SKULL WAS PERFOR
Patient problems: Cerebrospinal Fluid Leakage; No Known Impact Or Consequence To Patient
MAUDE report 7608984 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K092467. One submission often covers many models, so check the product and lot details in each record.
- Z-0056-2021 · Aug 31, 2020 · TerminatedUltrasound Navigation Software 1.0 and Ultrasound Integration Software for Cranial/ENT Navigation 3.0.x and 3.1.x - Product Usage: intended to be an intra-operative image guided l
- Z-0598-2016 · Apr 22, 2013 · TerminatedBrainlab Cranial Navigation System: An Image Guided Surgery System / Stereotactic. Radiology Departments. The BrainLAB Cranial IGS System is intended to be an intra-operative imag
Other Neurological Stereotaxic Instrument devices
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument4 deaths4,668 reports
- Stealthstation® S7™ 9733856Medtronic Navigation, Inc. · Neurological stereotaxic Instrument6 deaths3,908 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death1,896 reports
- StealthStation S8 9735669Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1,831 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument2 deaths1,542 reports
- Fusion™ ENT Image Guidance System 9733560XOMMedtronic Navigation, Inc. · Neurological stereotaxic Instrument1,316 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument8 deaths984 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death695 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page