Reference Star Iop Imaging 19145-01Recalls & reported problems
Brainlab SE · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04056481004620), received between Nov 8, 2016 and Nov 8, 2016.
The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).
2 other recalls cover devices cleared under the same FDA submission (K092467); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Improper or Incorrect Procedure or Method1
- Mechanical Problem1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
Nov 8, 2016Mechanical Problem; Improper or Incorrect Procedure or Method; Mechanical Problem; Improper or Incorrect Procedure or Method
A MINIMALLY INVASIVE SPINE SURGERY FOR AN ODONTOID SCREW PLACEMENT WAS PLANNED TO BE PERFORMED WITH THE AID OF BRAINLAB NAVIGATION SYSTEM SPINE & TRAUMA 3D 2.5. DURING THE PROCEDURE THE SURGEON: - FIXATED THE PATIENT'S HEAD IN A THIRD PARTY HEAD CLAMP AND ATTACHED THE NAVIGATION REFERENCE ARRAY TO THE HEAD CLAMP. - PERFORMED AN AUTOMATIC IMAGE REGISTRATION (MATCHING OF VIRTUAL DISPLAY OF PATIENT IMAGE DATA AND ACTUAL PATIENT ANATOMY) IN COMBINATION WITH AN AIRO CT SCANNER. - ROTATED THE PATIENT TABLE BY 90 DEGREE AND MOVED THE NAVIGATION CAMERA FROM THE FOOT TO THE HEAD SIDE OF THE TABLE. - SWITCHED THE REFERENCE ARRAY FROM UNSTERILE TO STERILE. - USED THE AID OF NAVIGATION TO DETERMINE THE ACCORDING ENTRY POINT AND ANGLE OF THE ODONTOID SCREW AND PLACED THE K-WIRE WITH THE AID OF NAVIGATION. - PLACED THE SCREW WITHOUT THE AID OF NAVIGATION. - PERFORMED A VERIFICATION SCAN WITH AN AIRO CT SCANNER TO CONFIRM CORRECT PLACEMENT OF THE SCREW AND DETECTED THAT THE SCREW PLACEMENT WAS NOT AS INTENDED. - REPLACED THE SCREW WITHOUT THE AID OF NAVIGATION. ACCORDING TO THE HOSPITAL, THE SURGERY COULD BE COMPLETED SUCCESSFULLY AND THERE WERE NO NEGATIVE CLINICAL EFFECTS FOR THE PATIENT DUE TO
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 6085379 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K092467. One submission often covers many models, so check the product and lot details in each record.
- Z-0056-2021 · Aug 31, 2020 · TerminatedUltrasound Navigation Software 1.0 and Ultrasound Integration Software for Cranial/ENT Navigation 3.0.x and 3.1.x - Product Usage: intended to be an intra-operative image guided l
- Z-0598-2016 · Apr 22, 2013 · TerminatedBrainlab Cranial Navigation System: An Image Guided Surgery System / Stereotactic. Radiology Departments. The BrainLAB Cranial IGS System is intended to be an intra-operative imag
Other Neurological Stereotaxic Instrument devices
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument4 deaths4,668 reports
- Stealthstation® S7™ 9733856Medtronic Navigation, Inc. · Neurological stereotaxic Instrument6 deaths3,908 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death1,896 reports
- StealthStation S8 9735669Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1,831 reports
- StealthStation S8 Platform 9735665Medtronic Navigation, Inc. · Neurological stereotaxic Instrument2 deaths1,542 reports
- Fusion™ ENT Image Guidance System 9733560XOMMedtronic Navigation, Inc. · Neurological stereotaxic Instrument1,316 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument8 deaths984 reports
- Stealthstation® S7™ 9733858Medtronic Navigation, Inc. · Neurological stereotaxic Instrument1 death695 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page