Skip to content

N/A 803365Recalls & reported problems

inomed Medizintechnik GmbH · Opti pin fixing pin 70 mm · Class 2

Data updated Oct 16, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04250307606221), received between Jun 25, 2025 and Jun 25, 2025 — classified as 1 malfunction.

The most frequently reported specific device problem is “Improper or Incorrect Procedure or Method” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 1 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Improper or Incorrect Procedure or Method1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionJun 25, 2025Improper or Incorrect Procedure or Method; Improper or Incorrect Procedure or Method

    A SALES REPRESENTATIVE FROM ZIMMER BIOMET ACCOMPANIED A FIRST-TIME USE OF THE RING AND THE OPTI PINS AT A NEW CUSTOMER IN THE USA. THE OPTI PINS WERE NOT POSITIONED VERTICALLY TO THE SKULL WHEN THE RING WAS POSITIONED ON THE PATIENT'S SKULL, BUT AT AN ANGLE. A TOOL PREVIOUSLY UNKNOWN TO US WAS USED TO TIGHTEN THE OPTI PIN. THE TORQUE SPANNER PROVIDED FOR THIS PURPOSE WAS NOT USED. THIS RESULTED IN PRELIMINARY DAMAGE TO THE OPTI PIN, WHICH WAS RECOGNISABLE BY A CLEAR BENDING OF THE PIN. THE PROCEDURE WAS CONTINUED. A ROSA ROBOT WAS USED TO IMPLANT SEEG ELECTRODES IN THE PATIENT. THE RING WAS USED AS A HOLDING AND REFERENCE SYSTEM FOR THE ROBOT ON THE PATIENT. IN THE COURSE OF THE OPERATION, THE PRE-DAMAGED OPTI PIN BROKE, WHICH LED TO A SLIGHT MOVEMENT OF THE RING AND THUS TO A CHANGE IN THE POSITION OF THE PATIENT IN RELATION TO THE RING. AS A RESULT, THE ROSA ROBOT NO LONGER HAD THE CORRECT TRAJECTORIES IN RELATION TO THE ACTUAL POSITION OF THE PATIENT. THIS LED TO DEVIATIONS FROM THE PLANNED TRAJECTORIES AND THUS TO INCORRECTLY POSITIONED SEEG ELECTRODES. THE PATIENT'S POSTOPERATIVE CONDITION DOES NOT SUGGEST ANY HEALTH IMPAIRMENTS.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 22332035 ↗

Other Neurological Stereotaxic Instrument devices

All Neurological Stereotaxic Instrument devices →