Skip to content

LAZIC 35.411Recalls & reported problems

Peter Lazic GmbH · D-CLIP APPLIER/ REMOVER, STANDARD/ MINI, WORKING LEGTH 90MM, BAYONET, RIGID JAW, DOUBLE ACTION, 210 MM · Class 2

1 open recall names this device. See the recall details and contact the manufacturer or your healthcare provider.

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
1

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04250603739609), received between Apr 9, 2024 and Apr 9, 2024 — classified as 1 malfunction.

The most frequently reported specific device problem is “Mechanical Problem” (1 report).

1 FDA recall record name this device's identifier, 1 still open.

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 1 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Recalls naming this device

  1. Oct 6, 2023Open, Classified

    Customer complaint received that reported the applier failed during surgery. The applier did not release the clip. The applier remained attached to the clip.

    Z-1278-2024 · Root cause: Device Design · FDA record ↗

Most reported problems

Device problems

  • Mechanical Problem1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionApr 9, 2024Mechanical Problem; Mechanical Problem

    THE INCIDENT OCCURED IN ECUADOR. OUR DISTRIBUTOR IN ECUADOR HAS RECEIVED THE FOLLOWING INFORMATION FROM HIS CUSTOMER: THE APPLIER FAILED DURING SURGERY. THE APPLIER DID NOT RELEASE THE CLIP. THE APPLIER REMAINED ATTACHED TO THE CLIP. THE AFFECTED APPLIER AND ALL SIMILAR APPLIERS WITH THE ARTICLE NUMBERS 35.410, 35.411 AND 35.412 ARE BEING REMOVED FROM THE MARKET. THESE ARE ALL APPLIERS WITH A RIGID JAW. IT IS PLANNED TO REDESIGN THE JAW PART OF THE APPLIER TO PREVENT THE DEFECT FROM RECURRING AS FAR AS POSSIBLE. TO THIS END, PROTOTYPES WERE PRODUCED AND GIVEN TO VARIOUS DOCTORS IN ORDER TO OBTAIN FEEDBACK ON THE REDESIGN OF THE JAW PARTS. THE PATIENT WAS NOT INJURED. HOWEVER, THE INCIDENT COULD HAVE LED TO A DETERIORATION OF THE HEALTH.

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 19069584 ↗

Other Applier, Aneurysm Clip devices

All Applier, Aneurysm Clip devices →

Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.