Vertecem II Cement Kit 08.702.017SRecalls & reported problems
OSARTIS GmbH · Vertecem II is a radio-opaque, injectable acrylic bone cement used for the treatment of pathological fractures of the vertebral body due to osteoporosis, cancer, or benign lesions using a Vertebroplasty or Kyphoplasty procedure. · Class 2 · Implant
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 6
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 6 adverse event reports that list this exact device (DI 04260056880759), received between Oct 25, 2018 and Jul 20, 2023 — classified as 1 injury, 5 malfunctions.
The most frequently reported specific device problem is “Migration or Expulsion of Device” (2 reports).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Most reported problems
Device problems
- Migration or Expulsion of Device2
- Adverse Event Without Identified Device or Use Problem1
- Chemical Problem1
- Device Damaged Prior to Use1
- Patient Device Interaction Problem1
- Unsealed Device Packaging1
- Use of Incorrect Control/Treatment Settings1
Patient problems
- No Consequences Or Impact To Patient3
- Failure of Implant1
- Insufficient Information1
- No Clinical Signs, Symptoms or Conditions1
- No Code Available1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 6 most recent of 6 reports, in the reporter's own words as published by the FDA.
MalfunctionJul 20, 2023Unsealed Device Packaging; Device Damaged Prior to Use; Unsealed Device Packaging; Device Damaged Prior to Use
IT WAS REPORTED THAT ON AN UNKNOWN DATE, A VERTECEM II MIXING KIT AND VERTECEM V+ SYRINGE KIT FOR A KYPHOPLSTY CASE DID NOT HAVE INTACT STERILE SEALS SO THE PHYSICIAN DID NOT WANT TO USE THEM AND WOULD LIKE REPLACEMENTS. BACK UP STOCK WAS AVAILABLE AND HE USED THOSE. NO EFFECT ON PATIENT WAS REPORTED.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17360025 ↗MalfunctionAug 23, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem
IT WAS REPORTED THAT ON (B)(6) 2021, DURING A KYPHOPLASTY CASE, THE SURGEON REPORTED THAT THE VERTECEM II MIXING KIT SOLIDIFIED IN 5 MINUTES. THE STAFF REPORTED THAT THEY TRIED A SECOND KIT WHICH ALSO SOLIDIFIED IN AN UNUSUALLY QUICK TIME PERIOD. ADDITIONAL INFORMATION HAS BEEN REQUESTED. NO MORE INFORMATION HAS BEEN PROVIDED BY THE USER FACILITY. THE PATIENT OUTCOME IS UNKNOWN.
Patient problems: Insufficient Information
MAUDE report 12352647 ↗InjuryAug 17, 2020Use of Incorrect Control/Treatment Settings; Patient Device Interaction Problem; Use of Incorrect Control/Treatment Settings; Patient Device Interaction Problem
IT WAS REPORTED THAT, THE VERTECEM II CEMENT WAS NOTICED TO HAVE EXTRUDED INTO THE PATIENT'S VENA CAVA. INITIALLY, THE PATIENT UNDERWENT AN L4 CORPECTOMY WITH SCREWS AND VERTECEM CEMENT AT L3-5 ON (B)(6) 2020. IT IS UNKNOWN HOW THE ISSUE WAS DISCOVERED. IT IS UNKNOWN IF THERE WAS A PATIENT CONSEQUENCE. CONCOMITANT DEVICE REPORTED: UNKNOWN SCREW (LOT # UNKNOWN). THIS COMPLAINT INVOLVES ONE (1) DEVICE.
Patient problems: Failure of Implant; No Code Available; No Known Impact Or Consequence To Patient
MAUDE report 10412947 ↗MalfunctionApr 24, 2019Chemical Problem; Chemical Problem
IT WAS REPORTED THAT A PATIENT UNDERWENT UNKNOWN PROCEDURE AT LEVEL T8 ON (B)(6) 2019 DUE TO VERTEBRAL COMPRESSION FRACTURES. DURING THE PROCEDURE THE SURGICAL TECH WAS TRYING TO MIX THE VERTECEM II MIX KIT. THE T-HANDLE WAS STUCK AND NEVER ALLOWED HER TO MIX. IT IS UNKNOWN IF THERE WAS A SURGICAL DELAY. THERE WERE NO ADVERSE CONSEQUENCES TO THE PATIENT REPORTED. PROCEDURE AND PATIENT OUTCOME ARE UNKNOWN. THIS REPORT IS FOR ONE (1) VERTECEM II MIXING KIT-STERILE. THIS IS REPORT 1 OF 1 FOR COMPLAINT (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8546245 ↗MalfunctionOct 25, 2018Migration or Expulsion of Device; Migration or Expulsion of Device
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE ON (B)(6) 2018, UPON MIXING AND OPENING THE MIXER TO DISPENSE, VERTECEM CEMENT SPILLED OUT OF THE MIXER AS IF UNDER PRESSURE. THIS HAPPENED TO TWO (2) MIXERS AND SEEMED TO HAVE PRESSURE IN MIXING VALVE. CEMENT CAME OUT BEFORE STOP COCK COULD BE APPLIED BUT ONCE STOP COCK WAS ATTACHED EVERYTHING WAS FINE. THIS MIGHT BE DUE TO A TECHNICAL ERROR IN MIXING AGGRESSIVELY ON THE BACK TABLE. SUFFICIENT CEMENT REMAINED AND WAS OF NORMAL VISCOSITY, SO THERE WAS NO IMPACT ON THE PATIENT AND NO DELAY ON THE LENGTH OF THE PROCEDURE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT FURTHER INCIDENT AND THE PATIENT OUTCOME WAS GOOD. THIS REPORT IS FOR ONE (1) VERTECEM II MIXING KIT-STERILE. THIS IS REPORT 2 OF 2 FOR COMPLAINT (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8006473 ↗MalfunctionOct 25, 2018Migration or Expulsion of Device; Migration or Expulsion of Device
IT WAS REPORTED THAT DURING AN UNKNOWN PROCEDURE ON (B)(6) 2018, UPON MIXING AND OPENING THE MIXER TO DISPENSE, VERTECEM CEMENT SPILLED OUT OF THE MIXER AS IF UNDER PRESSURE. THIS HAPPENED TO TWO (2) MIXERS AND SEEMED TO HAVE PRESSURE IN MIXING VALVE. CEMENT CAME OUT BEFORE STOP COCK COULD BE APPLIED BUT ONCE STOP COCK WAS ATTACHED EVERYTHING WAS FINE. THIS MIGHT BE DUE TO A TECHNICAL ERROR IN MIXING AGGRESSIVELY ON THE BACK TABLE. SUFFICIENT CEMENT REMAINED AND WAS OF NORMAL VISCOSITY, SO THERE WAS NO IMPACT ON THE PATIENT AND NO DELAY ON THE LENGTH OF THE PROCEDURE. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITHOUT FURTHER INCIDENT AND THE PATIENT OUTCOME WAS GOOD. THIS REPORT IS FOR ONE (1) VERTECEM II MIXING KIT-STERILE. THIS IS REPORT 1 OF 2 FOR COMPLAINT (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 8006460 ↗
Other Cement, Bone, Vertebroplasty devices
- CONFIDENCE SPINAL CEMENT SYSTEM 283910000Medos International Sàrl · CEMENT, BONE, VERTEBROPLASTY5 deaths163 reports
- CONFIDENCE SPINAL CEMENT SYSTEM 283913000Medos International Sàrl · CEMENT, BONE, VERTEBROPLASTY8 deaths146 reports
- KYPHON® Xpede™ Bone Cement and KYPHON® Mixer Pack CX01BMedtronic Sofamor Danek, Inc. · CEMENT, BONE, VERTEBROPLASTY3 deaths67 reports
- SYNFLATE 03.804.701SSynthes GmbH · CEMENT, BONE, VERTEBROPLASTY60 reports
- KYPHON® HV-R® Bone Cement C01AMedtronic Sofamor Danek, Inc. · CEMENT, BONE, VERTEBROPLASTY57 reports
- Cortoss 2101-0005Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall3 reports
- iVAS 0705315000Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall3 reports
- Cortoss 2101-0010Stryker Corporation · CEMENT, BONE, VERTEBROPLASTY1 recall1 report
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page