OTSC System Set 12/6 t - 220 (REF 100.31)Recalls & reported problems

Ovesco Endoscopy AG · The OTSC System Set consists of a clip preloaded onto an application cap • a handwheel and a thread retriever • it can be used in flexible endoscopy for acute bleedings, full thickness wall closure, compression as well as approximation of tissue and management of complications after endoscopic or surgical interventions • the clip closes itself and firmly anchors the tissue • constant force at the implantation site securing the therapeutic effect • made of a biocompatible material (Nitinol), can remain in the body as an implant · Class 2 · Implant

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04260206310334), received between Jul 25, 2025 and Jul 25, 2025 — classified as 1 injury.

The most frequently reported specific device problem is “Use of Device Problem” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 1 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Use of Device Problem1

Patient problems

  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • InjuryJul 25, 2025Use of Device Problem; Use of Device Problem

    THE OTSC WAS USED FOR THE TREATMENT OF A BLEEDING IN THE DUODENAL BULB. A TWIN GRASPER WAS USED FOR TISSUE MOBILIZATION. THE TISSUE WAS FIBROTIC AND THEREFORE DIFFICULT TO MOBILIZE INTO THE CAP. THE USER DID NOT REALIZE THAT THE GRASPING INSTRUMENT HAD NOT BEEN RETRACTED FAR ENOUGH INTO THE CAP. IN THE FOLLOWING THE TWIN GRASPER WAS ACCIDENTALLY CLIPPED TO THE TISSUE. THE PATIENT WAS THEN ADMITTED TO THE HOSPITAL THE FOLLOWING DAY TO HAVE THE GRASPING DEVICE REMOVED. IN THE MEANTIME, THE GRASPER HAD DETACHED ITSELF FROM THE CLIP AND COULD BE REMOVED WITHOUT ANY PROBLEMS. THE CLIP WAS STILL FIRMLY IN PLACE IN THE TISSUE AND HAD SEALED THE HAEMORRHAGE. NO FURTHER TREATMENT OF THE PATIENT WAS NECESSARY.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 22607138 ↗

Other Hemostatic Metal Clip For The Gi Tract devices

All Hemostatic Metal Clip For The Gi Tract devices →