EIT CIF Inserter CET30101Recalls & reported problems
EIT Emerging Implant Technologies GmbH · Inserter · Class 2
Data updated Oct 18, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 5
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 5 adverse event reports that list this exact device (DI 04260397080214), received between Sep 8, 2020 and Feb 10, 2025 — classified as 5 malfunctions.
The most frequently reported specific device problem is “Break” (4 reports).
2 other recalls cover devices cleared under the same FDA submission (K170503); they may or may not involve this specific model.
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.
Reports received per month
Most reported problems
Device problems
- Break4
- Corroded2
- Device-Device Incompatibility1
Patient problems
- No Clinical Signs, Symptoms or Conditions4
- No Consequences Or Impact To Patient1
Recent adverse event reports
The 5 most recent of 5 reports, in the reporter's own words as published by the FDA.
MalfunctionFeb 10, 2025Break; Corroded; Break; Corroded
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE REPORTED INSTRUMENTS WERE RUSTY, HAD BROKEN THREADS AND BROKEN TIPS. THERE WAS NO PATIENT CONSEQUENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21343462 ↗MalfunctionFeb 10, 2025Break; Corroded; Break; Corroded
IT WAS REPORTED THAT ON AN UNKNOWN DATE, THE REPORTED INSTRUMENTS WERE RUSTY, HAD BROKEN THREADS AND BROKEN TIPS. THERE WAS NO PATIENT CONSEQUENCE.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 21343457 ↗MalfunctionSep 28, 2023Break; Break
DEVICE REPORT FROM AUSTRALIA REPORTS AN EVENT AS FOLLOWS: IT WAS REPORTED THAT DURING A PROCEDURE ON (B)(6) 2023, THE TENSION ARM SNAPPED AND FELL OFF AS THE SURGEON WAS ABOUT TO IMPLANT THE CAGE. THE LOCKING NUT HELD THE INSERTER HANDLES CLOSED, SO THE EVENT DID NOT HAVE AN IMPACT ON THE OPERATION. THE PROCEDURE WAS COMPLETED SUCCESSFULLY WITH NO DELAY AND NO ADVERSE PATIENT IMPACT. NO FURTHER INFORMATION IS AVAILABLE TO REPORT. THIS REPORT IS FOR AN INSERTER. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 17837893 ↗MalfunctionMay 7, 2022Device-Device Incompatibility; Device-Device Incompatibility
DEVICE REPORT FROM SYNTHES REPORTS AN EVENT IN UNITED KINGDOM AS FOLLOWS: IT WAS REPORTED DURING PREP (PRE-OPERATIVELY) THAT AN INSERTER WAS NO LONGER ABLE TO CONNECT TO IMPLANT TO INSERT. THE DIAL DOES NOT LOCK. NO PATIENT INVOLVEMENT. THIS IS REPORT 1 OF 1 FOR PC- (B)(4). THIS REPORT IS FOR AN INSERTER.
Patient problems: No Clinical Signs, Symptoms or Conditions
MAUDE report 14316103 ↗MalfunctionSep 8, 2020Break; Break
IT WAS REPORTED THAT ON AN UNKNOWN DATE, DURING AN UNKNOWN PROCEDURE, THE CONDUIT CERVICAL IMPLANT INSERTER WAS BROKEN. THE SPRING THAT ALLOWS THE INSERTER TO OPEN WAS DAMAGED. IT IS UNKNOWN IF FRAGMENTS WERE GENERATED AND REMOVED. SURGICAL DELAY IS UNKNOWN. THERE WERE NO PATIENT CONSEQUENCES. PROCEDURE OUTCOME IS UNKNOWN. THIS REPORT IS FOR ONE (1) INSERTER. THIS IS REPORT 1 OF 1 FOR (B)(4).
Patient problems: No Consequences Or Impact To Patient
MAUDE report 10501742 ↗
Recalls under the same FDA submission
These recalls involve devices cleared under K170503. One submission often covers many models, so check the product and lot details in each record.
- Z-1324-2022 · May 20, 2022 · Open, ClassifiedEIT CIF cage, H 7mm, 8degree, S- an intervertebral body fusion devices indicated for use with autograft when used as an adjunct to fusion in patients with cervical disc disease (DD
- Z-1323-2022 · May 20, 2022 · Open, ClassifiedEIT CIF cage, H 6mm, 8degree, L- an intervertebral body fusion devices indicated for use with autograft when used as an adjunct to fusion in patients with cervical disc disease (DD
Other Intervertebral Fusion Device With Bone Graft, Cervical devices
- ROI-C MC1005TLDR Spine Usa, Inc. · Intervertebral Fusion Device With Bone Graft, Cervical54 reports
- EIT CIF cage CUI8070SEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall4 reports
- EIT CIF cage CUI8060LEIT Emerging Implant Technologies GmbH · Intervertebral Fusion Device With Bone Graft, Cervical1 recall1 report
- CONSTRUX - MINI Ti 37-7212SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8015SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-7206SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI Ti 37-8007SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
- CONSTRUX - MINI PTC 37-4211SPOrthofix US LLC · Intervertebral fusion device with bone graft, cervical1 recall0 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 18, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page