Skip to content

EIT PLIF cage PUI31106Recalls & reported problems

EIT Emerging Implant Technologies GmbH · EIT PLIF, H 11mm, 12°, 26/9 · Class 2 · Implant

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
1
Deaths reported
0
Injuries reported
0
Recalls naming it
0

Summary

The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04260557820612), received between Feb 14, 2023 and Feb 14, 2023 — classified as 1 malfunction.

The most frequently reported specific device problem is “Break” (1 report).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Most reported problems

Device problems

  • Break1

Patient problems

  • No Clinical Signs, Symptoms or Conditions1

Recent adverse event reports

The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.

  • MalfunctionFeb 14, 2023Break; Break

    IT WAS REPORTED THAT DURING A SPINAL PROCEDURE ON (B)(6) 2023, THE SURGEON VERBALIZED THAT THE PATIENT HAD VERY HARD BONE DURING THE DISC PREPARATION PORTION OF THE CASE. THE CAGE WAS INSERTED AND ROTATED USING A LOT OF FORCE AND TORQUE. THE CAGE BROKE AT THE JUNCTION OF WHERE THE INSERTER MEETS THE CAGE. THE SURGERY WAS COMPLETED SUCCESSFULLY WITH NO SURGICAL DELAY. FRAGMENTS WERE GENERATED BUT THE RETAINED PIECE WAS ATTACHED TO THE INSERTER AND DID NOT INVOLVE ADDITIONAL INTERVENTION TO REMOVE. THERE WERE NO PATIENT CONSEQUENCES. THE PATIENT OUTCOME WAS GOOD AND NO OTHER MEDICAL INTERVENTION WAS REQUIRED. THIS REPORT INVOLVES ONE EIT PLIF, H 11MM, 12°, 26/9. THIS IS REPORT 1 OF 1 FOR (B)(4).

    Patient problems: No Clinical Signs, Symptoms or Conditions

    MAUDE report 16371613 ↗

FDA clearance and classification

The FDA regulates product code MAX (intervertebral fusion device with bone graft, lumbar) under 21 CFR 888.3080 as a Class II device. 21 CFR 888.3080 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

FDA definition of this device type: Intended to stabilize spinal segment to promote fusion in order to restrict motion and decrease pain using bone graft.

Common questions about the EIT PLIF cage PUI31106

Has the EIT PLIF cage PUI31106 been recalled?

No FDA recall record in our data names this exact device identifier (DI 04260557820612), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the EIT PLIF cage PUI31106?

The FDA's MAUDE database lists 1 adverse event report for this device, received on Feb 14, 2023. That report lists device problem “Break” (1). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the EIT PLIF cage PUI31106?

None of the reports are classified as deaths, 0 as injuries and 1 as a malfunction. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the EIT PLIF cage PUI31106 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the EIT PLIF cage PUI31106, and is it still sold?

The FDA's device database lists EIT Emerging Implant Technologies GmbH as the company responsible for it (brand EIT PLIF cage, model PUI31106). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Intervertebral Fusion Device With Bone Graft, Lumbar devices

All Intervertebral Fusion Device With Bone Graft, Lumbar devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page