RX NC TAKERU DC-RZ3015UA2Recalls & reported problems
Kaneka Corporation · RX NC TAKERU is a Percutaneous Transluminal Coronary Angioplasty (PTCA) Balloon Dilatation Catheter for coronary indications. RX NC TAKERU is a rapid exchange (RX) type and the maximum diameter of the compatible guidewire is 0.014 inches (0.36 mm). · Class 2
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04540778170513), received between Feb 19, 2019 and Feb 19, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Material Separation” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Material Separation1
- Use of Device Problem1
Patient problems
- Device Embedded In Tissue or Plaque1
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryFeb 19, 2019Material Separation; Use of Device Problem; Material Separation; Use of Device Problem
CTO CASE WAS BEING PERFORMED WITH A HIGH CALCIUM LESION. THE PHYSICIAN WAS ABLE TO GET RADIAL ACCESS AND USED A GUIDE CATHETER (7FR, EBU 3.75) INTO THE LCA AND ADVANCED A GUIDEWIRE (ASAHI FIELDER XT, ASAHI INTECC) AND A TRAPLINER (TELEFLEX) DOWN THE CIRC. THE PHYSICIAN ADVANCED THE RX NC TAKERU OVER THE GUIDEWIRE TO THE CALCIFIED LESION. THE RX NC TAKERU WAS INFLATED TO 20 ATM AND BURST DUE TO THE CALCIUM. THE RX NC TAKERU WAS WEDGED INTO THE CALCIUM VALVE AND WHEN THE PHYSICIAN PULLED BACK TO REMOVE THE BALLOON, THE BALLOON SPLIT AND PARTIAL OF IT WAS LEFT BEHIND. THE PHYSICIAN THEN WAS ABLE TO PASS A ROTABLATOR (BOSTON SCIENTIFIC) 1.5 BURR PASS THE LESION AND BROKE UP THE BALLOON PIECE THAT WAS LEFT BEHIND. HE DID NOT TRY TO REMOVE THE PIECES AND LEFT IT IN THE PATIENT AND HAS NO CONCERN WITH IT. HE STATED THAT THE PIECES ARE SUBINTIMAL AND IS NOT CONCERNED TO HAVE THE PIECES THERE.
Patient problems: Device Embedded In Tissue or Plaque; No Known Impact Or Consequence To Patient
MAUDE report 8352648 ↗
Other Catheters, Transluminal Coronary Angioplasty, Percutaneous devices
- MINI TREK™ 1012270-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous223 reports
- Maverick²™ H7493892815200Boston Scientific Corporation · Catheters, transluminal coronary angioplasty, percutaneous1 death203 reports
- MINI TREK™ 1012270-12Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous162 reports
- Maverick²™ H7493892820200Boston Scientific Corporation · Catheters, transluminal coronary angioplasty, percutaneous161 reports
- NC TREK 1012454-08Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous2 recalls59 reports
- TREK™ 1012272-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous2 deaths158 reports
- NC TREK 1012453-12Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous1 recall84 reports
- NC TREK 1012453-15Abbott Vascular Inc. · Catheters, transluminal coronary angioplasty, percutaneous1 recall1 death83 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page