Skip to content

EXETER 0580-1-501Recalls & reported problems

Howmedica Osteonics Corp. · V40 STEM · Class 2 · Implant

All models of EXETER (36)

Data updated Nov 27, 2026 from official FDA records · Editorial policy

Adverse event reports
13
Deaths reported
0
Injuries reported
10
Recalls naming it
0

Summary

The FDA's MAUDE database contains 13 adverse event reports that list this exact device (DI 04546540153364), received between Sep 10, 2018 and Feb 19, 2026 — classified as 10 injuries, 3 malfunctions.

The most frequently reported specific device problem is “Insufficient Device Problem Information” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Nov 27, 2026.

Reports received per month

Dec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 0 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 1 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reportsNov 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Insufficient Device Problem Information5
  • Break4
  • Fracture4
  • Adverse Event Without Identified Device or Use Problem3
  • Fitting Problem2
  • Degraded1

Patient problems

  • Insufficient Information4
  • Ambulation or Postural Difficulties3
  • Bone Fracture(s)2
  • Injury2
  • No Known Impact Or Consequence To Patient2
  • Metal Related Pathology1
  • No Consequences Or Impact To Patient1
  • Pain1

Recent adverse event reports

The 13 most recent of 13 reports, in the reporter's own words as published by the FDA.

  • InjuryFeb 19, 2026Adverse Event Without Identified Device or Use Problem

    THIS PI IS FOR THE JR IMPLANTS. IT WAS REPORTED THAT THE PATIENT'S RIGHT HIP WAS REVISED DUE TO PROXIMAL FEMORAL FRACTURE REP CONFIRMED FRACTURE WAS PROXIMAL TO AXSOS 3 CORTEX SCREWS AND THAT NO SCREWS WERE DAMAGED. ALL IMPLANTS WERE REMOVED. STRYKER ACETABULAR COMPONENTS AND COMPETITOR FEMORAL COMPONENTS WERE IMPLANTED. REP CONFIRMED THAT NO FURTHER INFORMATION WILL BE RELEASED BY THE HOSPITAL OR SURGEON.

    Patient problems: Bone Fracture(s); Periprosthetic fracture

    MAUDE report 24390636 ↗
  • InjuryAug 15, 2022Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information; Adverse Event Without Identified Device or Use Problem; Insufficient Device Problem Information

    PATIENT REPORTED A PRIMARY STRYKER THA WAS IMPLANTED IN HER LEFT HIP (B)(6) 2022 1 DAY POST-OP, PATIENT NOTICED A LIMB LENGTH DISCREPANCY OF APPROXIMATELY AN ADDITIONAL .75" ON HER OPERATIVE SIDE (PATIENT IS 65" STANDING ON HER RIGHT FOOT, 65.75" STANDING ON HER LEFT FOOT). INDEX SURGEON PROPOSED TO IMPLANT A THA ON THE CONTRALATERAL SIDE TO MATCH LIMB LENGTHS. AFTER SEEKING A SECOND OPINION, A REVISION OF THE HIP IS SCHEDULED (B)(6) 2022. REVISING SURGEON REPORTED TO THE PATIENT THAT THE IMPLANTS WERE TOO LARGE FOR THE PATIENT'S ANATOMY. PATIENT IS INQUIRING IF THERE HAVE BEEN OTHER REPORTS OF LIMB LENGTH DISCREPANCY REPORTED WITH THE INDEX SURGEON OR WITH HER IMPLANTS. UPDATE (B)(6) 2022 (B)(6): CLARIFICATION FROM PATIENT: "I'M NOT SURE HE [REVISING SURGEON] ACTUALLY SAID IT WAS TOO BIG FOR MY ANATOMY, MORE THAT THE ANGLE WAS WRONG. WE DIDN'T REALLY UNDERSTAND. ON MY LAST POST OP VISIT WITH THE ORIGINAL DOCTOR HE CHANGED HIS PLAN FROM DOING MY RIGHT HIP TO HAVING PELVIC OBLIQUITY PHYSICAL THERAPY FOR MY LEFT AND GETTING A SPECIAL SHOE MADE."

    Patient problems: Ambulation or Postural Difficulties; Unequal Limb Length

    MAUDE report 15223184 ↗
  • InjuryMay 20, 2022Fracture; Fracture

    THE FOLLOWING WAS REPORTED: REVISION TOTAL HIP REPLACEMENT. BROKEN EXETER STEM REMOVED DURING PROCEDURE.

    Patient problems: Ambulation or Postural Difficulties

    MAUDE report 14460595 ↗
  • InjuryNov 1, 2021Adverse Event Without Identified Device or Use Problem; Adverse Event Without Identified Device or Use Problem

    REVISION CASE.

    Patient problems: Insufficient Information

    MAUDE report 12726719 ↗
  • InjuryOct 4, 2021Fitting Problem; Insufficient Device Problem Information; Fitting Problem; Insufficient Device Problem Information

    DURING A THA REVISION, THE SURGEON REMOVED A 50 NO.1 CEMENTED STEM AND ATTEMPTED TO REPLACE THE STEM WITH ANOTHER 50 NO.1 ¿ HE INDICATED THE STEM WAS WIDER AT THE BOTTOM COMPARED TO THE PREVIOUS STEM AND THEREFORE COULD NOT USE IT- THIS RESULTED IN A DELAY TO THE CASE AND ULTIMATELY A SMALLER STEM BEING INSERTED. (B)(6) 2021 UPDATE: TWO STEMS WERE TRIED DURING THE CASE AND BOTH WERE REPORTED TO HAVE FIT ISSUES SURGICAL DELAY WAS ESTIMATED AT 120 MINUTES WHILE ATTEMPTING TO REMOVE CEMENT MANTLE AND PLACE SUITABLE STEM IN ADDITION, THE PATIENT WAS GIVEN (B)(4) UNITS OF RED BLOOD CELLS INTRA-OPERATIVELY AS RESULT OF BLOOD LOSS THROUGHOUT THE CASE

    Patient problems: Insufficient Information

    MAUDE report 12568076 ↗
  • InjuryOct 4, 2021Fitting Problem; Insufficient Device Problem Information; Fitting Problem; Insufficient Device Problem Information

    DURING A THA REVISION, THE SURGEON REMOVED A 50 NO.1 CEMENTED STEM AND ATTEMPTED TO REPLACE THE STEM WITH ANOTHER 50 NO.1 ¿ HE INDICATED THE STEM WAS WIDER AT THE BOTTOM COMPARED TO THE PREVIOUS STEM AND THEREFORE COULD NOT USE IT- THIS RESULTED IN A DELAY TO THE CASE AND ULTIMATELY A SMALLER STEM BEING INSERTED. 07SEP21: UPDATE: TWO STEMS WERE TRIED DURING THE CASE AND BOTH WERE REPORTED TO HAVE FIT ISSUES. SURGICAL DELAY WAS ESTIMATED AT 120 MINUTES WHILE ATTEMPTING TO REMOVE CEMENT MANTLE AND PLACE SUITABLE STEM. IN ADDITION, THE PATIENT WAS GIVEN 4 X UNITS OF RED BLOOD CELLS INTRA-OPERATIVELY AS RESULT OF BLOOD LOSS THROUGHOUT THE CASE.

    Patient problems: Insufficient Information

    MAUDE report 12568075 ↗
  • InjuryJun 1, 2021Break; Fracture; Break; Fracture

    ON THE (B)(6)THE PATIENT WAS COOKING IN THE KITCHEN. THE PATIENT TURNED AROUND AND DROPPED THROUGH HIS LEG OR SLIPPED. PATIENT IMMEDIATELY WASN¿T ABLE ANYMORE TO LOAD THE LEFT LEG. PATIENT WAS BROUGHT IN WITH THE AMBULANCE. PATIENT HAS A BROKEN EXETER STEM.

    Patient problems: Ambulation or Postural Difficulties; Insufficient Information

    MAUDE report 11912619 ↗
  • InjuryOct 5, 2020Degraded; Insufficient Device Problem Information; Degraded; Insufficient Device Problem Information

    REVISION SURGERY ON STRYKER IMPLANTS. REPLACED WITH STRYKER STEM AND FEMORAL HEAD AND DEPUY CUP AND INSERT (B)(6) 2020. PATIENT COMPLAINT OF PAIN AND SQUEAK / CLUNKINESS. SIGNS OF TRUNIONOSIS AND IMPINGEMENT NOTED BY SURGEON. STRIPE WEAR ON CERAMIC HEAD. LINER RIM DAMAGED BY WEAR FROM STEM REVISION ON PREVIOUS PRIMARY SURGERY.

    Patient problems: Metal Related Pathology; Pain

    MAUDE report 10631105 ↗
  • InjuryJun 16, 2020Insufficient Device Problem Information; Insufficient Device Problem Information

    RIGHT FEMORAL PERIPROSTHETIC FRACTURE. NOTICED AFTER SURGEON REVIEW OF X-RAY AFTER PT FELL OVER.

    Patient problems: Bone Fracture(s); Injury

    MAUDE report 10157599 ↗
  • InjuryMay 21, 2019Fracture; Fracture

    THE CUSTOMER REPORTED THAT A PATIENT WHO HAD BEEN IMPLANTED WITH AN EXETER STEM IN 2009 DURING A THR HAS UNDER GONE A REVISION. THE PATIENT TRIPPED WITHOUT FALLING IN (B)(6) 2019 AND HEARD A SNAP. THE PATIENT PRESENTED TO THE EMERGENCY DEPT AND THE X-RAY SHOWED A FRACTURED STEM. THE CUSTOMER FURTHER REPORTED THAT THE STEM HAD FRACTURED AT THE NECK

    Patient problems: Injury

    MAUDE report 8629253 ↗
  • MalfunctionMay 20, 2019Break; Break

    DURING COMMUNICATION, THE THEATRE MANAGER REPORTED THAT THE SURGEON COMMENTED THAT SIMILAR EVENT MIGHT HAVE HAPPENED BEFORE TO THEIR COLLEAGUES. THE EVENT WAS THAT THE PLASTIC CENTRALIZER FITTED TO STEM BUCKLED. UPDATE 29/APRIL/2019 (B)(6): AS REPORTED BY HOSPITAL STAFF, A SURGICAL DELAY OF APPROXIMATELY 10 MINUTES WAS REPORTED.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8624523 ↗
  • MalfunctionMay 6, 2019Break; Break

    CUSTOMER REPORTED TO (B)(6) THAT THE PLASTIC CENTRALISER FITTED TO STEM BUCKLED, SO WOULD NOT FIT THE STEM INTRODUCER. AN ALTERNATIVE WAS FOUND TO COMPLETE THE CASE. UPDATE: DELAY OF SURGERY 10 MIN.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 8583615 ↗
  • MalfunctionSep 10, 2018Break; Fracture; Break; Fracture

    THE CUSTOMER REPORTED THAT THEY OPENED AN EXETER STEM AND NOTICED THAT THE LUG HAD BROKEN OFF THE SPIGGOT PROTECTOR. A NEW IMPLANT WAS USED TO COMPLETE THE CASE.

    Patient problems: No Consequences Or Impact To Patient

    MAUDE report 7861833 ↗

FDA clearance and classification

The FDA regulates product code KWL (prosthesis, hip, hemi-, femoral, metal) under 21 CFR 888.3360 as a Class II device. 21 CFR 888.3360 ↗

Devices of this type normally need 510(k) clearance before sale.

Manufacturers may send malfunction reports for this device type to the FDA in quarterly summaries, where one report can stand for several events.

Common questions about the EXETER 0580-1-501

Has the EXETER 0580-1-501 been recalled?

No FDA recall record in our data names this exact device identifier (DI 04546540153364), based on the FDA recall file dated Nov 27, 2026. Recalls are sometimes announced by product family or lot, so the manufacturer’s own notices are worth checking too.

What problems have been reported with the EXETER 0580-1-501?

The FDA's MAUDE database lists 13 adverse event reports for this device, received between Sep 10, 2018 and Feb 19, 2026. In those reports, the most common specific device problems are “Break” (4), “Fracture” (4) and “Fitting Problem” (2); the most common patient problems are “Ambulation or Postural Difficulties” (3), “Bone Fracture(s)” (2) and “Injury” (2). Reports are not verified by the FDA and do not prove the device caused the problem.

Have deaths or injuries been reported with the EXETER 0580-1-501?

None of the reports are classified as deaths, 10 as injuries and 3 as malfunctions. The classification is chosen by whoever filed the report, and a death report does not mean the device caused the death.

Is the EXETER 0580-1-501 MRI safe?

According to the device's FDA GUDID record, its labeling lists it as MR Conditional: it can be scanned only under the specific conditions given in the labeling. The radiology team should check those conditions before an MRI.

Who makes the EXETER 0580-1-501, and is it still sold?

The FDA's device database lists Howmedica Osteonics Corp. as the company responsible for it (brand EXETER, model 0580-1-501). Its record shows it as in commercial distribution.

Answers are built automatically from the FDA records on this page. They are not medical advice.

Other Prosthesis, hip, hemi-, femoral, metal devices

All Prosthesis, hip, hemi-, femoral, metal devices →

Sources and updates

How reports and recalls are matched · Editorial policy · Report an error on this page