Duracon 6642-9-616Recalls & reported problems
Howmedica Osteonics Corp. · Constrained Tibial Insert · Class 2 · Implant
All models of Duracon (58)
Data updated Oct 16, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 0
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540319371), received between Jun 13, 2018 and Jun 13, 2018 — classified as 1 malfunction.
The most frequently reported specific device problem is “Device-Device Incompatibility” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 16, 2026.
Most reported problems
Device problems
- Device-Device Incompatibility1
- Labelling, Instructions for Use or Training Problem1
Patient problems
- No Known Impact Or Consequence To Patient1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
MalfunctionJun 13, 2018Labelling, Instructions for Use or Training Problem; Device-Device Incompatibility; Labelling, Instructions for Use or Training Problem; Device-Device Incompatibility
I WAS NOTIFIED ON MONDAY THE (B)(6) BY ONE OF OUR LOCAL DOCTORS THAT HE NEEDED DURACON CR INSERTS AVAILABLE FOR A POLY SWAP ON THE (B)(6). DUE TO THE AVAILABILITY WE ONLY RECEIVED DURACON "CONSTRAINED" INSERT IMPLANTS. ONCE I WAS FOR CERTAIN THE AP LIPPED WEREN'T AVAILABLE, I THEN CONTACTED A MARKETING MANAGER AT CORPORATE TO INQUIRE ABOUT WHAT THE "CONSTRAINED" OPTION MEANT. SHE PROCEEDED TO TELL ME THIS WAS A DEEP DISH POLY VERSUS THE AP LIPPED. AS WE PROCEEDED WITH THE CASE, HE REMOVED THE OLD POLY, AND WE TRIALED WITH A CONDYLAR TRIAL AND ASKED ME TO OPEN THE SMALL 13MM IMPLANT (6642-9-613). THE DOCTOR WAS UNABLE TO MAKE IT SIT DOWN AND UNFORTUNATELY THE INSERT HIT THE FLOOR. WE THEN PROCEEDED TO THE 16MM INSERT (6642-9-616). THE DOCTOR AGAIN WAS HAVING PROBLEMS WITH IT LOCKING INTO THE BASEPLATE. WE INSPECTED THE POLY AND REALIZED THIS PARTICULAR IMPLANT WAS DESIGNED FOR A PCA BASEPLATE. DUE TO THE FACT THE BOX SIMPLY READ DURACON AS WELL THE INFORMATION MARKETING GAVE ME I WAS UNABLE TO PREVENT THIS OCCURRENCE. UPDATE: REP REPORTED THAT THE FIRST DEVICE "POPPED OUT" OF PATIENT AND HIT THE FLOOR OF THE OPERATING ROOM A SURGICAL DELAY OF APPROXIMATELY 20 MINUTES WAS REPORTED OV
Patient problems: No Known Impact Or Consequence To Patient
MAUDE report 7598185 ↗
Other Prosthesis, hip, semi-constrained, metal/polymer, cemented devices
- NA 1365-51-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented753 reports
- NA 1365-50-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented412 reports
- ARTICUL/EZE 1365-21-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 recall280 reports
- ARTICUL/EZE 1365-11-000Depuy (Ireland) · Prosthesis, hip, semi-constrained, metal/polymer, cemented1 death262 reports
- LFIT 6260-9-236Howmedica Osteonics Corp. · Prosthesis, hip, semi-constrained, metal/polymer, cemented256 reports
- PINNACLE GRIPTION 1217-32-052Depuy Orthopaedics, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented2 deaths239 reports
- ELEOS™ 25002111EOnkos Surgical, Inc. · Prosthesis, hip, semi-constrained, metal/polymer, cemented3 deaths230 reports
- Novation 130-36-52Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Metal/Polymer, Cemented2 recalls124 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 14, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 16, 2026
- Page last rebuilt: Oct 16, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page