Trident 508-11-58FRecalls & reported problems
Howmedica Osteonics Corp. · Hemispherical Acetabular Shell · Class 2 · Implant
Data updated Oct 13, 2026 from official FDA records · Editorial policy
- Adverse event reports
- 1
- Deaths reported
- 0
- Injuries reported
- 1
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 1 adverse event report that list this exact device (DI 04546540432230), received between Apr 1, 2019 and Apr 1, 2019 — classified as 1 injury.
The most frequently reported specific device problem is “Migration” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Most reported problems
Device problems
- Migration1
- Positioning Problem1
Patient problems
- Injury1
Recent adverse event reports
The 1 most recent of 1 reports, in the reporter's own words as published by the FDA.
InjuryApr 1, 2019Positioning Problem; Migration; Positioning Problem; Migration
IT WAS REPORTED THAT THE PATIENT'S LEFT HIP WAS REVISED DUE TO THE SHELL SHIFTING AND BECOMING ANTEVERTED. SURGEON CONFIRMED SHIFTING BY COMPARING POST-OP X-RAYS FROM PRIMARY IMPLANT ON (B)(6) 2019 AND POST-OP X-RAYS IN (B)(6) 2019. POSSIBLE CAUSE OR CONTRIBUTOR TO SHELL SHIFTING WAS NOT REPORTED TO REP. A SHELL, 2 SCREWS, LINER, BIOLOX CERAMIC HEAD AND ACCOLADE II STEM WERE REVISED TO A TRIDENT TRITANIUM REVISION SHELL WITH 5 SCREWS, AN ADM/MDM LINER CONSTRUCT, LFIT V40 METAL HEAD, AND ACCOLADE II STEM. THERE ARE NO ALLEGATIONS AGAINST THE LINER, HEAD, OR STEM.
Patient problems: Injury
MAUDE report 8470309 ↗
Other Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate devices
- Novation 130-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls156 reports
- Novation 130-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls79 reports
- CORAIL 3L92511Depuy (Ireland) · Prosthesis, hip, semi-constrained, uncemented, metal/polymer, non-porous, calicum-phosphate158 reports
- Acumatch A Series 138-36-29Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate3 recalls1 report
- Novation 136-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls43 reports
- Novation 130-32-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls33 reports
- Novation 132-32-51Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls26 reports
- Novation 136-36-53Exactech, Inc. · Prosthesis, Hip, Semi-Constrained, Uncemented, Metal/Polymer, Non-Porous, Calicum-Phosphate2 recalls22 reports
Sources and updates
- Device record: FDA GUDID, file dated Oct 13, 2026 · View this device in AccessGUDID ↗
- Adverse event reports: FDA MAUDE, file dated Oct 13, 2026 · each report above links to its original FDA record
- Recalls: FDA Medical Device Recalls, file dated Oct 13, 2026
- Page last rebuilt: Oct 13, 2026. Data downloaded through openFDA, which notes it is not validated for clinical or regulatory use.
How reports and recalls are matched · Editorial policy · Report an error on this page