APEX 5038-2-110SRecalls & reported problems

Stryker GmbH · Self-drilling Half Pin · Class 2 · Implant

All models of APEX (15)

Data updated Oct 18, 2026 from official FDA records · Editorial policy

Adverse event reports
8
Deaths reported
0
Injuries reported
1
Recalls naming it
0

Summary

The FDA's MAUDE database contains 8 adverse event reports that list this exact device (DI 04546540435408), received between Jul 30, 2018 and Sep 25, 2025 — classified as 1 injury, 7 malfunctions.

The most frequently reported specific device problem is “Break” (5 reports).

Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. What reports can and can't tell you · How this data works · Data updated Oct 18, 2026.

Reports received per month

Nov 2023: 0 reportsDec 2023: 0 reportsJan 2024: 0 reportsFeb 2024: 0 reportsMar 2024: 0 reportsApr 2024: 0 reportsMay 2024: 0 reportsJun 2024: 0 reportsJul 2024: 0 reportsAug 2024: 0 reportsSep 2024: 0 reportsOct 2024: 0 reportsNov 2024: 0 reportsDec 2024: 0 reportsJan 2025: 0 reportsFeb 2025: 0 reportsMar 2025: 0 reportsApr 2025: 0 reportsMay 2025: 0 reportsJun 2025: 0 reportsJul 2025: 0 reportsAug 2025: 0 reportsSep 2025: 1 reportsOct 2025: 0 reportsNov 2025: 0 reportsDec 2025: 0 reportsJan 2026: 0 reportsFeb 2026: 0 reportsMar 2026: 0 reportsApr 2026: 0 reportsMay 2026: 0 reportsJun 2026: 0 reportsJul 2026: 0 reportsAug 2026: 0 reportsSep 2026: 0 reportsOct 2026: 0 reports2024202520261
Last 36 months. The most recent month may be incomplete.

Most reported problems

Device problems

  • Break5
  • Fracture4

Patient problems

  • Foreign Body In Patient5
  • No Known Impact Or Consequence To Patient2
  • Device Embedded In Tissue or Plaque1

Recent adverse event reports

The 8 most recent of 8 reports, in the reporter's own words as published by the FDA.

  • InjurySep 25, 2025Break; Fracture; Break; Fracture

    AS REPORTED: "DURING A PRECISION NAVIGATION TKA CASE. THE APEX PIN SNAPPED INSIDE THE PATIENTS TIBIA DURING INSERTION AT THE START OF THE CASE. THE BROKEN END COULD NOT BE RETRIEVED AND A NEW PIN WAS OPENED AND USED. SURGICAL DELAY WHILE TRYING TO RETRIEVE THE BROKEN END."

    Patient problems: Foreign Body In Patient

    MAUDE report 23144772 ↗
  • MalfunctionNov 13, 2020Fracture; Fracture

    AS REPORTED: " 3 X STERILE APEX PINS REF NUMBER, (B)(4) WERE USED IN A NAVIGATED HIGH TIBIAL OSTEOTOMY CASE, INSERTED WITH A WIRED DRIVER, UPON REMOVAL WITH THE WIRE DRIVER POST FINISHING THE CASE IT WAS NOTED THAT THE TIPS OF THE PINS HAD BROKEN OFF. NOTICED AFTER SURGERY WAS COMPLETED AND REMOVING THE PINS."

    Patient problems: Foreign Body In Patient

    MAUDE report 10840129 ↗
  • MalfunctionNov 13, 2020Fracture; Fracture

    AS REPORTED: " 3 X STERILE APEX PINS REF NUMBER , (B)(4) WERE USED IN A NAVIGATED HIGH TIBIAL OSTEOTOMY CASE, INSERTED WITH A WIRED DRIVER, UPON REMOVAL WITH THE WIRE DRIVER POST FINISHING THE CASE IT WAS NOTED THAT THE TIPS OF THE PINS HAD BROKEN OFF. NOTICED AFTER SURGERY WAS COMPLETED AND REMOVING THE PINS."

    Patient problems: Foreign Body In Patient

    MAUDE report 10839995 ↗
  • MalfunctionNov 13, 2020Fracture; Fracture

    AS REPORTED: " 3 X STERILE APEX PINS REF NUMBER , (B)(4) WERE USED IN A NAVIGATED HIGH TIBIAL OSTEOTOMY CASE, INSERTED WITH A WIRED DRIVER, UPON REMOVAL WITH THE WIRE DRIVER POST FINISHING THE CASE IT WAS NOTED THAT THE TIPS OF THE PINS HAD BROKEN OFF. NOTICED AFTER SURGERY WAS COMPLETED AND REMOVING THE PINS."

    Patient problems: Foreign Body In Patient

    MAUDE report 10839954 ↗
  • MalfunctionAug 29, 2019Break

    APEX PINS WERE USED TO ATTACH AN ORTHOLOCK TO THE TIBIA DURING A NAVIGATED TOTAL KNEE. THE TIP OF THE APEX PIN DRILL WAS BROKEN AT THE TIME OF REMOVAL OF THE PIN FROM THE TIBIAL SHAFT AND RETAINED IN THE BONE.

    Patient problems: Device Embedded In Tissue or Plaque

    MAUDE report 8946783 ↗
  • MalfunctionAug 29, 2019Break

    APEX PINS WERE USED TO ATTACH AN ORTHOLOCK TO THE TIBIA DURING A NAVIGATED TOTAL KNEE. THE TIP OF THE APEX PIN DRILL WAS BROKEN AT THE TIME OF REMOVAL OF THE PIN FROM THE TIBIAL SHAFT AND RETAINED IN THE BONE. SURGICAL DELAY. THE SURGEON DECIDED TO X-RAY THE PATIENTS TIBIA TO CONFIRM THE TIP OF THE APEX PIN WAS STILL LODGED IN THE CORTEX.

    Patient problems: Foreign Body In Patient

    MAUDE report 8946675 ↗
  • MalfunctionJul 30, 2018Break

    BROKEN 3 MM APEX PINS DURING REMOVAL FROM BONE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7732920 ↗
  • MalfunctionJul 30, 2018Break

    BROKEN 3MM APEX PINS DURING REMOVAL FROM BONE.

    Patient problems: No Known Impact Or Consequence To Patient

    MAUDE report 7732855 ↗

Other PIN, FIXATION, THREADED devices

All PIN, FIXATION, THREADED devices →