XIA 3 482316550Recalls & reported problems
Stryker Corporation · POLYAXIAL SCREW · Class 2 · Implant
- Adverse event reports
- 2
- Deaths reported
- 0
- Injuries reported
- 2
- Recalls naming it
- 0
Summary
The FDA's MAUDE database contains 2 adverse event reports that list this exact device (DI 04546540562258), received between Aug 3, 2016 and Jun 25, 2024 — classified as 2 injuries.
The most frequently reported specific device problem is “Break” (1 report).
Reports come from manufacturers, hospitals and patients and are not verified by the FDA. A report does not prove the device caused the event, and counts can't be used to compare devices or estimate failure rates. How this data works · Data updated Oct 13, 2026.
Reports received per month
Most reported problems
Device problems
- Break1
- Fracture1
- Noise, Audible1
Patient problems
- No Code Available1
- Pain1
Recent adverse event reports
The 2 most recent of 2 reports, in the reporter's own words as published by the FDA.
InjuryJun 25, 2024Fracture; Fracture
A PATIENT WAS REVISED TO ADDRESS A FRACTURED XIA POLYAXIAL SCREW AT RIGHT S1. THE PATIENT REPORTED PAIN AND CT SCAN IDENTIFIED THE FRACTURED SCREW. THE FRACTURED SHAFT WAS UNABLE TO BE REMOVED DURING REVISION AND REMAINS IN THE PATIENT; THE REPLACEMENT SCREW WAS PLACED IN THE BONE SLIGHTLY LATERAL TO THE FRACTURED SHAFT.
Patient problems: Pain
MAUDE report 19611070 ↗InjuryAug 3, 2016Break; Noise, Audible
IT WAS REPORTED THAT A SCREW HAD BROKEN 3-4 MONTHS AFTER PRIMARY SURGERY AND REVISION SURGERY WAS NEEDED TO CORRECT IT. THE SCREW WAS IN S1. THE CUSTOMER REPORTED THAT THE PATIENT PRESENTED WITH A SQUEAK NOISE.
Patient problems: No Code Available
MAUDE report 5842983 ↗
Other Pedicle screw spinal system, adolescent idiopathic scoliosis devices
- CD HORIZON® Spinal System 5540030Medtronic Sofamor Danek, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis230 reports
- CD HORIZON® Spinal System 7578302Medtronic Sofamor Danek, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis122 reports
- EXPEDIUM 179762480Medos International Sàrl · Pedicle screw spinal system, adolescent idiopathic scoliosis114 reports
- ReLine 13550000Nuvasive, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis55 reports
- CD HORIZON® Spinal System 5440030Medtronic Sofamor Danek, Inc. · Pedicle screw spinal system, adolescent idiopathic scoliosis50 reports
- EXPEDIUM 179712640Medos International Sàrl · Pedicle screw spinal system, adolescent idiopathic scoliosis28 reports
- EXPEDIUM VIPER 196789300Depuy Spine, LLC · Pedicle screw spinal system, adolescent idiopathic scoliosis18 reports
- EXPEDIUM 179788635Medos International Sàrl · Pedicle screw spinal system, adolescent idiopathic scoliosis18 reports
Sources: FDA GUDID, MAUDE and Medical Device Recalls via openFDA. openFDA data is not validated for clinical or regulatory use.